Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Woodward In Stock OK

WOODWARD SST-ESR2-CLX TCP Interface Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for SST-ESR2-CLX.

Exact partSST-ESR2-CLX RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandWoodward Part NumberSST-ESR2-CLX ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ SST-ESR2-CLX

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Woodward
Primary Part Number
SST-ESR2-CLX
Product Type
PLC Communication Module
Product Family
Other series
Manufacturer
WOODWARD
Country of Origin
US
Model Function
EtherNet/IP TCP Interface Configuration Module
Catalog Category
Communication
Operating Temp.
0 °C to +60 °C
Humidity
5–95% RH, non-condensing
Warranty
12 months
Model confirmed for inquiry SST-ESR2-CLX Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

WOODWARD SST-ESR2-CLX EtherNet/IP TCP Interface Module – Stop the Clock on Your Downtime

Every minute your turbine control system or compressor train sits idle, the losses compound. A failed SST-ESR2-CLX doesn’t just drop a communication link — it can cascade into a full unit trip, a safety system lockout, or a forced production curtailment that costs more per hour than this module costs outright. We keep verified stock of the WOODWARD SST-ESR2-CLX on the shelf in Xiamen, ready to clear customs and land on your bench faster than your OEM’s lead time even gets quoted.

This is not a grey-market pull. It is not a refurbished unit dressed up in fresh packaging. The SST-ESR2-CLX we ship is genuine WOODWARD, batch-traceable, firmware-verified, and dispatched with a full documentation package. When your maintenance window is measured in hours, you cannot afford to gamble on provenance.

⚡ URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Manufacturer WOODWARD
Part Number SST-ESR2-CLX
Series SST (Smart System Technology)
Function EtherNet/IP TCP Interface Configuration Module
Protocol EtherNet/IP (ODVA), TCP/IP
Target Platform Allen-Bradley ControlLogix (CLX)
Backplane Compatibility 1756 ControlLogix Series
Configuration Tool WOODWARD Toolkit / Studio 5000
Operating Temperature 0 °C to +60 °C
Humidity 5–95% RH, non-condensing
Vibration Rating IEC 60068-2-6 compliant
Condition New, Genuine OEM
Stock Status ✔ Ready to Ship – Xiamen Warehouse
Lead Time Same-day dispatch on confirmed orders before 15:00 CST
Warranty 12 months

Troubleshooting & Replacement Tips

Most Common Failure Signatures on the SST-ESR2-CLX:

  • Solid red STATUS LED with no Ethernet link: The module has lost its IP configuration or the firmware has become corrupted. Before condemning the hardware, attempt a factory reset via the WOODWARD Toolkit and re-push the configuration file. If the STATUS LED remains red after a clean config push, the module’s flash memory is likely degraded — replace the unit.
  • Intermittent EtherNet/IP connection drops under load: Typically caused by a failing internal capacitor on the power rail or a marginal Ethernet PHY. Swapping the module is faster than chasing the root cause on a live system. Log the I/O fault codes from the ControlLogix controller (fault code 16#0204 or 16#0203 in the connection status tag) before pulling the module — these codes confirm whether the fault originates at the module or the network switch.
  • Module not recognized by ControlLogix backplane after power cycle: Check the backplane slot assignment in your RSLogix/Studio 5000 project. The SST-ESR2-CLX does not support automatic slot self-addressing on all firmware revisions — the slot number must match the physical chassis position exactly. Mismatch causes a Module Type Mismatch fault (fault code 16#0107).
  • Firmware version mismatch warning in Studio 5000: The CLX variant of the SST-ESR2 requires a specific AOP (Add-On Profile) revision. If you are replacing an older unit, download the matching AOP from WOODWARD’s support portal before going online. Running a mismatched AOP version will prevent the controller from establishing a Class 1 connection.

Step-by-Step Hot-Swap Replacement Procedure:

  1. Place the ControlLogix controller in Program mode. Do not power down the chassis unless your safety procedures require it — the SST-ESR2-CLX supports inhibited module replacement on most firmware revisions.
  2. Inhibit the module in Studio 5000 (right-click → Properties → Connection → Inhibit Module). This prevents the controller from generating a major fault during removal.
  3. Note the existing IP address, subnet mask, and gateway from the module’s current configuration file or from the WOODWARD Toolkit backup. You will need these for the replacement unit.
  4. Remove the old module. Inspect the backplane connector pins for corrosion or mechanical damage before seating the new unit.
  5. Seat the replacement SST-ESR2-CLX. Apply the saved IP configuration via WOODWARD Toolkit or via the controller’s MSG instruction if your application uses dynamic IP assignment.
  6. Un-inhibit the module in Studio 5000 and switch the controller back to Run mode. Verify the green RUN and NET LEDs illuminate within 30 seconds. Monitor the connection status tag for 60 seconds to confirm stable Class 1 I/O connection.
  7. Document the replaced module’s batch code and firmware revision in your maintenance log. Retain the failed unit for failure analysis if required by your site’s reliability program.

Reliability in Harsh Conditions

The SST-ESR2-CLX was engineered for environments that would kill consumer-grade networking hardware inside a week. WOODWARD’s SST Series design spec targets continuous operation in the following conditions — and our stock units are verified to meet these ratings:

Vibration & Mechanical Shock: Qualified to IEC 60068-2-6 sinusoidal vibration and IEC 60068-2-27 mechanical shock profiles. In turbine hall installations where the floor vibrates at 10–150 Hz continuously, the SST-ESR2-CLX’s conformal-coated PCB and ruggedized connector system maintain signal integrity without the micro-fractures that develop in standard commercial modules over 12–18 months of exposure.

Thermal Cycling: Rated for 0 °C to +60 °C operating range with storage down to -40 °C. In outdoor compressor enclosures in the Middle East or Siberian gas fields, where ambient temperatures swing 50+ degrees between night and day, the module’s thermal design prevents the solder joint fatigue that causes intermittent faults in lesser hardware.

Humidity & Condensation: The conformal coating on the SST-ESR2-CLX PCB provides protection against humidity up to 95% RH non-condensing. In coastal petrochemical plants and offshore platforms where salt-laden air accelerates corrosion, this coating is the difference between a 5-year service life and a 6-month replacement cycle.

Electromagnetic Immunity: Designed to IEC 61131-2 EMC requirements, including immunity to conducted and radiated RF interference, electrostatic discharge (ESD), and fast transients. In switchgear rooms and motor control centers where VFDs generate significant EMI, the SST-ESR2-CLX maintains clean TCP/IP communication without the packet loss that plagues unshielded alternatives.

Global Express Logistics

Our Xiamen warehouse is positioned 40 minutes from Xiamen Gaoqi International Airport (XMN), one of China’s primary cargo hubs with direct freight connections to Dubai, Frankfurt, Los Angeles, Singapore, and Sydney. This geography is deliberate — it means your replacement module moves from our shelf to an international flight in hours, not days.

Standard Express Dispatch Process:

  • Order confirmed before 15:00 CST: Module is picked, inspected, packed in ESD-safe anti-static bag with foam-lined export carton, and handed to DHL Express or FedEx International Priority courier the same business day.
  • Export documentation: Commercial invoice, packing list, and Country of Origin declaration are prepared simultaneously with packing. No customs delays caused by missing paperwork.
  • Typical transit times: Southeast Asia 1–2 days | Middle East 2–3 days | Europe 2–4 days | North America 3–5 days | Australia 2–3 days.
  • Tracking: AWB number provided within 2 hours of dispatch. Real-time tracking link sent directly to your email or WhatsApp.
  • Urgent freight: For critical shutdowns, we can arrange next-flight-out courier service to most major industrial hubs. Contact us before 12:00 CST for same-day flight options.

All international shipments include full export compliance documentation. HS Code classification, ECCN review, and end-user declaration support available on request for regulated destinations.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.