WEIDMULLER 17234700000 PCB Terminal Block
Request verified availability, condition, replacement risk review, packing options and courier lead time for 17234700000.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Weidmuller
- Primary Part Number
- 17234700000
- Product Type
- PCB Terminal Block
- Product Family
- Other series
- Manufacturer
- WEIDMULLER
- Country of Origin
- Germany
- Catalog Category
- Industrial Automation Spares
- Operating Temp.
- -40°C to +105°C
- Compliance
- CE, RoHS 2, IEC 60947, UL Recognized
WEIDMULLER 17234700000 PCB Terminal Block – Stop the Clock on Your Downtime
Every minute a line sits idle costs money. When a WEIDMULLER 17234700000 connector fails mid-shift, you don’t have time to chase a distributor’s 4-week lead time. We stock this part in Xiamen, China — verified, boxed, and ready to clear customs today. One call, one shipment, line back up.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Value |
|---|---|
| Manufacturer | WEIDMULLER |
| Part Number | 17234700000 |
| Series | Klippon Connect PCB Terminal Block |
| Connection Method | Screw clamp / Push-in (series-dependent) |
| Rated Voltage | Per IEC 60664-1 (see datasheet) |
| Rated Current | Per conductor cross-section (see datasheet) |
| Mounting | PCB / DIN Rail compatible |
| Housing Material | High-grade thermoplastic (PA66) |
| Contact Material | Tin-plated copper alloy |
| Operating Temperature | -40°C to +105°C |
| Compliance | CE, RoHS 2, IEC 60947, UL Recognized |
| Country of Origin | Germany |
| Stock Status | ✔ READY TO SHIP – Xiamen Warehouse |
Troubleshooting & Replacement Tips
Pulled from real field experience — here’s what actually goes wrong with PCB terminal blocks in this class and how to handle the swap without creating a second fault.
Fault 1 — Intermittent Signal Loss / Erratic I/O Readings
Nine times out of ten this is a micro-arc at the screw clamp caused by vibration-induced loosening over time. Before condemning the block, torque every screw to spec (typically 0.5–0.6 Nm for this pitch class). If the fault clears, schedule a preventive re-torque on the full panel. If it returns within 48 hours, the contact surface is pitted — replace the block.
Fault 2 — Visible Discoloration / Burn Marks on Housing
Thermal runaway from sustained overcurrent or a high-resistance joint. Do not re-use the wiring on that circuit — strip back 15 mm and re-terminate with fresh ferrules. Inspect the PCB pad underneath for delamination before fitting the replacement 17234700000. A damaged pad will kill the new block within weeks.
Fault 3 — Push-in Cage Clamp Won’t Release
Common in environments with fine metallic dust. The release lever pivot corrodes and seizes. Use a 3 mm flat-blade tool — never a screwdriver tip wider than the slot. Forcing it shears the lever. If seized, the block must be replaced; do not attempt to free it with heat.
Replacement Procedure (PCB-mounted variant)
- De-energize the circuit and verify with a CAT III meter — do not rely on PLC output status alone.
- Label every wire before removal. Use heat-shrink markers, not tape — tape falls off in humid cabinets.
- If the block is soldered to the PCB, use a solder sucker and low-melt alloy (Chip Quik or equivalent) to avoid pad lift. Excessive heat is the #1 cause of board damage during connector replacement.
- Inspect the PCB footprint under magnification. Clean with IPA and a stiff brush. Check for cracked traces with a continuity tester before fitting the new block.
- Seat the WEIDMULLER 17234700000 squarely — misalignment by even 0.3 mm will stress the solder joints under vibration.
- Re-terminate wires in the original sequence. Torque to manufacturer spec. Tug-test each wire at 20 N before powering up.
- Power up with the PLC in STOP mode. Verify signal integrity on each channel before releasing to RUN.
Configuration Notes: This connector series does not carry address DIP switches — addressing is handled at the module or backplane level. Confirm your PLC rack slot assignment and I/O mapping in the CPU configuration before going live. Firmware compatibility is not a concern for passive connector components; however, if this block interfaces with a smart terminal or fieldbus coupler, verify the coupler firmware version matches your GSD/EDS file.
Reliability in Harsh Conditions
WEIDMULLER’s Klippon Connect series was not designed for a climate-controlled server room. It was built for the floor — the kind of environment where ambient temperature swings 40°C between morning startup and afternoon peak load, where coolant mist settles on open panels, and where a forklift passing three meters away sends a 5g shock through the cabinet frame.
The 17234700000 housing is molded from PA66 thermoplastic, which maintains dimensional stability and dielectric strength from -40°C to +105°C without creep. The tin-plated copper contacts are designed to resist fretting corrosion — the micro-wear mechanism that destroys cheaper connectors in high-vibration applications like compressor skids, press lines, and mobile equipment. IEC 60068-2 vibration and shock testing is part of the qualification baseline for this product family, not an optional certification.
In high-humidity environments (coastal plants, food processing, chemical dosing stations), the PA66 housing resists moisture absorption better than nylon 6, which means the creepage and clearance distances specified in the datasheet remain valid even after years of exposure. This is not a marketing claim — it is a material property you can verify in the WEIDMULLER product datasheet and IEC 60664-1 compliance documentation.
Bottom line: if the original block lasted years in your application, the replacement 17234700000 will too — provided the root cause of the failure has been addressed before installation.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international gateways. This is not a drop-ship arrangement. Stock is physically on our shelves, inspected, and ready to pick.
Standard Express (DHL / FedEx International Priority): Orders confirmed before 14:00 CST ship same day. Transit times: Southeast Asia 1–2 days, Middle East / Europe 3–4 days, Americas 4–5 days. Real-time tracking provided at dispatch.
Economy Air (ePacket / China Post Registered): Available for low-value single-unit orders where cost outweighs speed. Transit 7–15 days depending on destination customs clearance.
Sea Freight (LCL/FCL): For bulk orders exceeding 50 kg or high-volume BOM sourcing projects. Xiamen port offers weekly sailings to major global ports. Contact us for freight consolidation options.
Export Documentation Included: Commercial invoice, packing list, certificate of origin (CO), and HS code declaration (HS 8536.90) are prepared for every shipment. For orders requiring a FORM E (ASEAN-China FTA) or EUR.1 movement certificate, notify us at order placement.
We have shipped to over 40 countries. Customs clearance delays are rare when documentation is complete — and ours always is.
Contact Information
Line down? Don’t wait. Reach us directly:
- Email: [email protected]
- WhatsApp: +86 18359268345
- Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved. All trademarks are the property of their respective owners. We supply genuine OEM parts only.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.