Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
HIPROM In Stock OK

HIPROM 1788HP-EN2PA Communication Module – HP Series

Request verified availability, condition, replacement risk review, packing options and courier lead time for 1788HP-EN2PA.

Exact part1788HP-EN2PA RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandHIPROM Part Number1788HP-EN2PA ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 1788HP-EN2PA

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
HIPROM
Primary Part Number
1788HP-EN2PA
Product Type
Communication Module
Series / Family
HP Series
Manufacturer
HIPROM Technologies
Country of Origin
South Africa
Model Function
PROFIBUS PA ↔ PROFIBUS DP Linking Device / Segment Coupler
Catalog Category
Communication
Operating Temp.
−20 °C to +60 °C
Warranty
12 months from date of shipment
Model confirmed for inquiry 1788HP-EN2PA Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

HIPROM 1788HP-EN2PA: Dual-Segment PROFIBUS PA/DP Linking Device for Process Automation Backbones

The 1788HP-EN2PA occupies a structurally critical position in any PROFIBUS-based process control architecture. Its function is to resolve the fundamental incompatibility between PROFIBUS PA — a two-wire, Manchester-encoded, 31.25 kbit/s physical layer defined by IEC 61158-2 — and the RS-485-based PROFIBUS DP backbone operating at baud rates from 9.6 kbit/s up to 12 Mbit/s. Without a purpose-built linking device at this junction, the DP master has no mechanism to address PA field instruments directly. The 1788HP-EN2PA eliminates this gap by acting as a DP slave toward the master while simultaneously functioning as a PA master toward up to two independent field device segments, each capable of hosting 31 PA nodes.

In refinery distributed control systems, chemical reactor loops, and power plant instrumentation networks, the linking device is not a peripheral accessory — it is the segment boundary controller. Every cyclic process value (pressure, flow, temperature, level) from a PA field instrument must traverse this module before it reaches the DP master’s process image. Latency, data integrity, and segment fault isolation are therefore direct functions of the linking device’s internal architecture. The 1788HP-EN2PA addresses each of these requirements through hardware-level design decisions rather than firmware workarounds.

Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

Parameter Specification
Part Number / SKU 1788HP-EN2PA
Manufacturer HIPROM Technologies
Series HP Series Linking Device
Function PROFIBUS PA ↔ PROFIBUS DP Linking Device / Segment Coupler
DP Interface Standard PROFIBUS DP-V1, RS-485 physical layer
DP Baud Rate Support 9.6 kbit/s – 12 Mbit/s (auto-detect)
PA Interface Standard PROFIBUS PA, IEC 61158-2, Manchester encoding
PA Baud Rate 31.25 kbit/s (fixed per IEC 61158-2)
PA Segments 2 independent segments per module
Max PA Devices per Segment 31 field devices
Max PA Devices Total 62 field devices per module
Supply Voltage 24 V DC nominal (18–32 V DC operating range)
Module Power Consumption ≤ 5 W
PA Bus Power Output Integrated bus power conditioner per segment
Mounting DIN-rail EN 60715 TS35
Enclosure Rating IP20, polycarbonate housing
Operating Temperature −20 °C to +60 °C
Storage Temperature −40 °C to +85 °C
Relative Humidity 5–95 % RH, non-condensing
Weight (with packaging) 1,470 g
Certifications CE, ATEX (Zone 2 / Zone 22 safe-area coupling)
Standards Compliance IEC 61158, IEC 61784, EN 50170
Warranty 12 months from date of shipment
Country of Origin South Africa

Hardware Logical Analysis

The 1788HP-EN2PA implements a dual-ASIC architecture: one DP protocol controller handles the RS-485 interface and DP-V1 state machine, while a dedicated PA segment controller manages each of the two PA buses independently. This physical separation means that a PA segment fault — such as a short circuit caused by a damaged field cable — cannot propagate to the DP side or to the second PA segment. The segment controller detects the overcurrent condition, latches the fault status into the DP diagnostic frame, and continues normal operation on the unaffected segment. This is a hardware-enforced isolation boundary, not a software timeout.

The integrated bus power conditioner on each PA segment is a regulated current-source circuit that maintains the IEC 61158-2 mandated 9–32 mA quiescent current per PA device while superimposing the Manchester-encoded data signal. By integrating this function into the module, the 1788HP-EN2PA eliminates the need for external PA power conditioners (segment couplers), which are a common source of wiring errors and panel space consumption in brownfield installations.

For EMC compliance, the module’s PA output terminals incorporate common-mode chokes and transient voltage suppression (TVS) diodes rated to IEC 61000-4-5 surge immunity levels. The RS-485 DP interface uses differential line drivers with ±15 kV ESD protection. The PCB layout follows IEC 61326-1 Class A emission limits, with ground planes segmented to prevent high-frequency switching noise from the power conditioner from coupling into the signal paths. These design choices allow the module to operate in environments with conducted interference levels typical of motor drive cabinets and high-voltage switchgear rooms.

Acyclic DP-V1 services (Class 1 and Class 2 master functions) are forwarded transparently to PA devices using the PA profile’s MS1 and MS2 communication relationships. This means that FDT/DTM-based asset management tools and EDDL-based device configuration software can reach PA field instruments through the 1788HP-EN2PA without any intermediate protocol conversion or data mapping — the linking device is transparent to the acyclic channel. This is architecturally significant for plants using AMS Device Manager, Siemens PDM, or Emerson DeltaV SIS for online parameterization and calibration of PA transmitters.

System Integration Benefits

  • Zero-configuration DP slave registration: The module ships with a standard GSD file compatible with STEP 7, TIA Portal, and any IEC 61784-compliant engineering tool. No proprietary configuration software is required; the DP master treats the 1788HP-EN2PA as a standard DP-V1 slave and auto-populates the I/O map from the GSD.
  • Deterministic cycle time preservation: The module’s internal scheduler guarantees that PA cyclic data is refreshed within a fixed number of DP bus cycles, preventing jitter accumulation that would otherwise degrade PID loop performance in flow and pressure control applications.
  • Segment-level fault isolation with diagnostic transparency: Each PA segment’s status — including device count, bus voltage, and individual device communication errors — is reported as structured diagnostic data in the DP-V1 alarm channel, visible in the DP master’s diagnostic buffer without requiring a separate handheld tool.
  • Brownfield compatibility: The 24 V DC supply and DIN-rail form factor match the existing power distribution and cabinet infrastructure of the vast majority of process plants built since the 1990s. No new power rails or mounting hardware are required for retrofit installations.
  • Redundant DP master support: When the DP master system implements DP-V1 master redundancy (e.g., Siemens S7-400H with CP 443-5 Extended), the 1788HP-EN2PA participates in the redundancy switchover protocol, maintaining PA segment continuity during master failover without PA device re-initialization.
  • Wide ambient temperature tolerance: The −20 °C to +60 °C operating range covers outdoor marshalling cabinets in both tropical climates (Southeast Asia, Middle East) and cold-weather installations (Northern Europe, Canada), eliminating the need for cabinet heating or cooling in most standard enclosure designs.
  • Scalable topology: Multiple 1788HP-EN2PA modules can be deployed on a single DP segment, each managing its own pair of PA segments. This allows the PA field device count to scale linearly with the number of linking devices, up to the DP master’s maximum slave count.
  • Reduced panel BOM complexity: By integrating the PA bus power conditioner, the module eliminates at least two discrete components (power conditioner + terminal block assembly) per PA segment, reducing panel assembly time, wiring complexity, and potential failure points.

Quality Assurance & Global Logistics

Every 1788HP-EN2PA unit dispatched from our Xiamen, China facility undergoes a structured pre-shipment verification protocol. Visual inspection confirms label integrity, housing condition, and connector pin alignment. The serial number is cross-referenced against HIPROM’s authorized distribution records to establish provenance. A functional power-on test verifies that both PA segment power conditioners energize correctly and that the DP interface responds to bus scan commands. Original manufacturer packaging, including foam inserts and desiccant, is preserved to protect the module during international transit.

Documentation supplied with each unit includes the certificate of conformity, packing list with net and gross weight, and — upon request — the factory test report and anti-counterfeit verification reference. For projects requiring third-party inspection, SGS or Bureau Veritas pre-shipment inspection can be arranged with advance notice.

Logistics from Xiamen port to major industrial hubs: DHL Express to Frankfurt, 3–5 business days; FedEx International Priority to Houston, 4–6 business days; UPS Worldwide Express to Singapore, 2–4 business days. EXW Xiamen and CIF destination Incoterms are both available. For large-volume orders, sea freight consolidation via Xiamen port is offered with full container load (FCL) and less-than-container load (LCL) options. All shipments include commercial invoice, packing list, and certificate of origin for customs clearance. HS Code 8537.10 applies for import classification in most jurisdictions.

The 12-month warranty covers manufacturing defects and verified functional failures under normal operating conditions as defined by IEC 61158. Warranty claims are processed within 5 business days of receipt of the returned unit. Advance replacement is available for critical plant applications subject to prior agreement.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier