6ES7315-6TH13-0AB0 CPU 315T-3 PN/DP — Stop the Clock on Your Downtime
Your motion axes are frozen. The PROFIBUS network is throwing DP slave errors. The shift supervisor is standing behind you. You already know the CPU is dead — you’ve seen this before. Every minute this rack sits idle costs real money: scrapped batches, missed shipments, penalty clauses. The Siemens 6ES7315-6TH13-0AB0 is on our shelf in Xiamen right now. We’ve shipped this exact module to plants in Germany, Thailand, Mexico, and Saudi Arabia — all on emergency timelines. We know what you need and we know how fast you need it.
The CPU 315T-3 PN/DP is not a general-purpose S7-300 CPU. It carries integrated motion control technology objects — up to 32 axes of positioning, synchronous operation, cam, and path interpolation — alongside simultaneous PROFINET IO and dual PROFIBUS DP interfaces. Replacing it with a standard 315-2 PN/DP is not an option. You need this exact order number, this exact firmware baseline, and you need it before the next shift starts.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Order Number | 6ES7315-6TH13-0AB0 |
| CPU Designation | CPU 315T-3 PN/DP |
| Product Family | SIMATIC S7-300 |
| Work Memory | 512 KB |
| Load Memory | 512 KB integrated RAM + MMC expandable |
| Binary Processing Speed | 0.05 ms / 1000 instructions |
| Communication Interfaces | 1× MPI/PROFIBUS DP (12 Mbit/s) + 1× PROFINET IO (100 Mbit/s) + 1× PROFIBUS DP (12 Mbit/s) |
| Technology Objects (Axes) | Up to 32 |
| Motion Functions | Positioning, synchronous operation, cam, path interpolation |
| Supply Voltage | 24 V DC via backplane bus |
| Operating Temperature | 0 °C to +60 °C |
| Firmware Baseline | V3.3 or higher |
| Programming Software | STEP 7 V5.5 SP4+ / SIMATIC SCOUT |
| Dimensions (W×H×D) | 80 × 125 × 130 mm |
| Weight | Approx. 490 g |
| Stock Status | ✔ Ready to Ship — Xiamen Warehouse |
Troubleshooting & Replacement Tips
Confirmed failure signatures before you pull the module:
- SF/BF LEDs both solid red on power-up — CPU halted, no OB1 execution
- STEP 7 hardware diagnostics returning event ID 0x2521 (internal CPU error) or 0x2522 (memory error)
- SCOUT axis status stuck at “Axis not referenced” with no communication to drives — DP master port unresponsive
- Repeated STOP → RUN transition failures with OB85 or OB86 calls logged in the diagnostic buffer
- MMC card readable but CPU refuses to load project — corrupted work memory, not the card
Before you swap — critical configuration checklist:
- MMC card: The CPU 315T-3 PN/DP stores the project on the Micro Memory Card. Pull the MMC from the failed unit first. If the card is intact, the replacement CPU will load the project automatically on first power-up — no STEP 7 download required. Verify card type: 6ES7953-8LJ31-0AA0 (8 MB) or 6ES7953-8LL31-0AA0 (4 MB). Do not use third-party MMC cards.
- MPI address: The CPU’s MPI node address is stored in the MMC project. If you’re loading from MMC, the address transfers automatically. If downloading fresh from STEP 7, set MPI address before going online — default is node 2.
- PROFINET device name: The PN interface device name is stored in the CPU’s non-volatile memory, not the MMC. After swapping, you must reassign the PROFINET device name using STEP 7 → PLC → Ethernet → Assign Device Name. Without this step, all PN IO slaves will report BF errors.
- PROFIBUS DP address switches: The 315T-3 PN/DP does not use physical DIP switches for DP addressing — the DP master address is set in HW Config. However, verify that downstream DP slaves (drives, ET 200 stations) have not had their physical address switches disturbed during the swap.
- Firmware version matching: If your SCOUT project was created with a specific CPU firmware version, a replacement unit with a newer firmware may require a SCOUT update before technology objects compile correctly. Check the firmware label on the CPU front panel. Target: V3.3 minimum; V3.3.3 recommended for isochronous DP stability.
- Technology object re-commissioning: After CPU swap and project load, go online in SCOUT and verify each axis status. Axes will typically show “Axis not enabled” — this is normal. Execute “Enable axis” and verify encoder feedback before releasing to production. Do not skip this step on synchronous axis groups.
- Backup battery / capacitor: The S7-300 CPU 315T-3 PN/DP uses an internal capacitor (not a replaceable battery) to retain RAM during brief power interruptions. On a new replacement unit, this capacitor is fully charged. No action required, but note that extended power-off periods (>30 days) will clear retentive data — the MMC project reloads, but retentive DB values reset to initial values.
Common fault codes you’ll see during restart:
- OB86 / Event 0x38C4: DP slave failure — expected during restart before all slaves come online. Clears automatically once network stabilizes.
- OB85 / Event 0x2833: Process image update error — check that all I/O modules in the rack are seated correctly after handling.
- SCOUT: “Drive not ready”: SINAMICS drives require a PROFIBUS/PROFINET re-parameterization cycle after CPU replacement. Cycle drive power and re-execute the SCOUT “Download to target system” for the affected axis.
Reliability in Harsh Conditions
The CPU 315T-3 PN/DP was designed for the factory floor, not the server room. Siemens qualifies the S7-300 platform to IEC 61131-2 and EN 61000-6-2 (industrial EMC immunity), which means it’s built to survive the electrical environment that kills consumer-grade hardware.
Vibration resistance is rated to 10–58 Hz at 0.075 mm amplitude and 58–150 Hz at 1g — covering the frequency range generated by most industrial machinery including compressors, presses, and conveyor drives. The conformal-coated PCB protects against condensation and airborne contaminants in environments where humidity cycles between 10% and 95% non-condensing. Operating temperature ceiling of 60 °C means it handles control cabinet summer temperatures without derating, provided cabinet ventilation meets Siemens installation guidelines (minimum 25 mm clearance above and below the rack).
Units we supply from our Xiamen warehouse are stored in climate-controlled conditions, individually sealed in anti-static ESD bags with desiccant packs. Long-term storage units undergo visual and electrical inspection before dispatch. We do not ship modules that show connector oxidation, PCB discoloration, or evidence of prior repair.
Global Express Logistics
Our dispatch hub is in Xiamen, Fujian — one of China’s primary export ports with direct DHL and FedEx gateway access. For emergency orders confirmed before 14:00 CST, same-day dispatch is standard. Transit times from Xiamen:
- Southeast Asia (Thailand, Vietnam, Malaysia, Indonesia): DHL Express — 2 to 3 business days
- Middle East (UAE, Saudi Arabia, Qatar): FedEx International Priority — 3 to 4 business days
- Europe (Germany, Poland, Italy, Netherlands): DHL Express — 3 to 5 business days
- North America (USA, Canada, Mexico): FedEx International Priority — 3 to 5 business days
- South Asia (India, Pakistan, Bangladesh): DHL Express — 3 to 4 business days
- Australia & New Zealand: DHL Express — 3 to 4 business days
Every shipment includes a commercial invoice, packing list, and certificate of origin for customs clearance. The HS code for this module is 8537.10 (programmable logic controllers). We declare accurate values — no undervaluation. For customers requiring formal export documentation or end-user certificates, contact us before order confirmation.
Packaging: double-boxed, foam-lined inner carton, outer corrugated carton rated for international air freight handling. Tracking numbers are issued within 2 hours of dispatch. We monitor shipments and proactively notify you of any customs holds.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.