Power Measurement In Stock OK

Power Measurement 3720-ACM Power Quality Meter – ION Series

Request verified availability, condition, replacement risk review, packing options and courier lead time for 3720-ACM.

Exact part3720-ACM RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandPower Measurement Part Number3720-ACM ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 3720-ACM

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Power Measurement
Primary Part Number
3720-ACM
Product Type
Power Quality Meter
Series / Family
ION Series
Manufacturer
Power Measurement Ltd. (Schneider Electric)
Country of Origin
Canada (Power Measurement Ltd., Victoria, BC)
Catalog Category
Industrial Automation Spares
Operating Temp.
-25°C to +70°C
Warranty
12 months operational warranty from siemensplc.com
Model confirmed for inquiry 3720-ACM Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

Power Measurement 3720-ACM: Revenue-Grade Power Quality Metering for Mission-Critical Electrical Infrastructure

The Power Measurement 3720-ACM is a three-phase, multi-function power quality meter built on Schneider Electric’s ION (Integrated Object Network) Series platform. It is engineered for deployment at utility metering points, industrial distribution switchgear, data center PDUs, and substation feeder panels where measurement accuracy, harmonic visibility, and open-protocol communications are mandatory engineering requirements — not optional features.

Unlike general-purpose panel meters, the 3720-ACM implements a simultaneous six-channel sampling architecture. All three voltage and three current inputs are digitized in phase-coherent synchrony, eliminating inter-channel phase skew that would otherwise corrupt power factor and reactive power calculations in non-linear load environments. The onboard DSP resolves harmonic content up to the 63rd order on both voltage and current channels, producing per-phase THD figures and individual harmonic magnitudes that satisfy IEEE 519-2022 compliance audit requirements without supplementary instrumentation.

The ION technology framework embedded in the 3720-ACM is a programmable logic engine that executes conditional calculations, setpoint comparisons, and relay control sequences internally. This means the meter can perform demand-limit alarming, time-of-use energy accumulation, and digital output switching based on measured parameters — functions that would otherwise require an external PLC or RTU. For system integrators, this reduces panel wiring complexity and eliminates a discrete control layer from the BOM.

Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

Model / SKU 3720-ACM
Manufacturer Power Measurement Ltd. (Schneider Electric)
Platform ION Series
Measurement Accuracy Class Class 0.5S per IEC 62053-22 (active energy); ±0.1% of reading
Voltage Input Range (L-N) 57.7 – 347 V AC direct; up to 765 kV via external VT
Current Input 1 A or 5 A CT secondary (nominal); overload: 10× In for 1 s
Frequency Range 45 – 65 Hz
Harmonic Analysis Up to 63rd harmonic, voltage and current, per phase
THD Measurement Per-phase THD-F and THD-R, ±0.1% resolution
Power Parameters Active (kW), Reactive (kVAR), Apparent (kVA), Power Factor, Displacement PF
Energy Accumulation kWh, kVARh, kVAh (import / export / net); non-volatile register retention
Demand Measurement Sliding window, block, or thermal demand; programmable interval 1–60 min
Communications Port 1 RS-485, Modbus RTU, up to 115,200 baud
Communications Port 2 (optional) Ethernet 10/100 Mbps, Modbus TCP/IP
Digital Inputs 4 × optically isolated, 5–240 V AC/DC
Digital Outputs 2 × Form-C relay, 5 A @ 250 V AC
Display Backlit LCD, multi-screen navigation, front-panel keypad configuration
Data Logging Internal non-volatile memory: trend logs, waveform capture, event records, min/max registers
Auxiliary Power Supply 85 – 265 V AC / 100 – 300 V DC, universal range
Power Consumption < 10 VA (auxiliary circuit)
Operating Temperature -25°C to +70°C
Storage Temperature -40°C to +85°C
Relative Humidity 5% – 95% non-condensing
Enclosure / Mounting Panel-mount, 96 × 96 mm cutout (DIN 43700); DIN-rail adapter available
Ingress Protection IP52 (front panel)
Weight 1,260 g
Certifications CE, UL 61010-1, CSA C22.2, IEC 61010-1, IEC 62053-22
Country of Origin Canada (Power Measurement Ltd., Victoria, BC)
Warranty 12 months operational warranty from siemensplc.com

Hardware Logical Analysis

The 3720-ACM’s measurement front-end is built around a simultaneous-sampling ADC array. Unlike multiplexed architectures — where a single ADC time-shares across input channels — the 3720-ACM samples all six input channels (3V + 3I) at the same clock edge. This phase-coherent acquisition eliminates the inter-channel time skew that multiplexed designs introduce, which can reach several microseconds and produce measurable errors in reactive power and power factor at fundamental frequency, and compounding errors at harmonic frequencies.

The DSP computes a full DFT across the sampled window for each channel independently. Harmonic bins from the 1st through 63rd are extracted per phase, enabling the meter to report not only aggregate THD but also the magnitude and phase angle of each individual harmonic component. This granularity is required for IEEE 519-2022 compliance verification, where the standard specifies individual harmonic voltage limits (e.g., 3% for the 5th harmonic at the PCC) rather than aggregate THD alone.

The ION programming engine operates as a deterministic rule processor. Each ION module (arithmetic, comparator, counter, timer, setpoint) executes in a fixed scan cycle, producing outputs that can be wired to other modules or to physical I/O. This architecture allows the 3720-ACM to implement demand-limit relay control, time-of-use tariff switching, and waveform-triggered data capture entirely within the meter firmware — without external logic controllers. The relay outputs (Form-C, 5 A @ 250 V AC) are driven directly by ION setpoint modules, with configurable hysteresis and time delays to prevent contact chatter on noisy feeders.

EMC performance is addressed at the hardware level. The voltage and current input circuits incorporate common-mode chokes and transient voltage suppressors rated to IEC 61000-4-5 (surge immunity, 2 kV line-to-earth). The RS-485 communication port includes galvanic isolation to 2.5 kV, preventing ground loop currents from corrupting Modbus frames in installations where the meter and the host SCADA system share different ground references — a common condition in industrial switchgear panels.

System Integration Benefits

  • Deterministic Modbus Response: The RS-485 Modbus RTU implementation uses a fixed register map with documented response timing, allowing SCADA poll cycles to be sized accurately without empirical tuning. Typical response latency is <100 ms at 9,600 baud for a standard 20-register read.
  • Ethernet Option for High-Speed SCADA: The optional Modbus TCP/IP module enables sub-second data refresh rates over standard Ethernet infrastructure, supporting integration with OSIsoft PI, Wonderware System Platform, Ignition SCADA, and GE iFIX without protocol gateways.
  • Waveform Capture for Fault Diagnosis: Triggered oscillography stores pre- and post-fault voltage and current waveforms in internal memory. These records can be retrieved via Modbus or ION Setup software for root-cause analysis of nuisance trips, capacitor bank switching transients, and motor start events.
  • Non-Volatile Energy Registers: Energy accumulation registers (kWh, kVARh, kVAh) are stored in EEPROM and survive auxiliary power loss without data corruption. This is a mandatory requirement for revenue metering applications where register continuity must be demonstrated to the utility.
  • Programmable Demand Intervals: Sliding window, block, and thermal demand algorithms are all available and selectable via front-panel or software. This allows the meter to match the demand calculation method used by the local utility tariff, ensuring that on-site demand readings agree with the utility bill.
  • Digital Input Pulse Accumulation: The four optically isolated digital inputs accept pulse outputs from external meters (gas, water, steam), enabling the 3720-ACM to serve as a multi-utility data concentrator at a single Modbus node address.
  • Wide Auxiliary Supply Range: The 85–265 V AC / 100–300 V DC universal auxiliary supply eliminates the need for separate AC and DC variants in mixed-power installations such as battery-backed switchgear and UPS-fed control panels.
  • Front-Panel Diagnostics: The backlit LCD provides real-time display of all measured parameters, active alarms, and communication status without requiring a laptop or software connection. This reduces commissioning time and simplifies field troubleshooting by maintenance personnel.

Quality Assurance & Global Logistics

Every Power Measurement 3720-ACM unit supplied by siemensplc.com is sourced through verified distribution channels with full traceability to the original Power Measurement / Schneider Electric manufacturing record. Incoming inspection covers visual examination of the enclosure and terminal markings, label verification against the manufacturer’s serial number format, and a functional power-on test confirming display operation and Modbus communication response.

Units are shipped from our Xiamen, China warehouse via DHL Express, FedEx International Priority, or UPS Worldwide Expedited — carrier selection based on destination country and customer preference. Standard transit times are 3–5 business days to major industrial hubs in Southeast Asia, the Middle East, and Europe; 5–7 business days to North America and South America. Export documentation (commercial invoice, packing list, HS code 9028.30 declaration) is prepared in compliance with Chinese customs regulations and destination country import requirements. EXW Xiamen and CIF destination Incoterms are both available.

All units carry a 12-month operational warranty from siemensplc.com covering defects in materials and workmanship under normal operating conditions. Warranty claims are processed with a target response time of 48 hours. Replacement units are dispatched from Xiamen stock; defective units are returned via prepaid courier label. For new-in-box units, the original Schneider Electric factory warranty terms apply in addition to the siemensplc.com warranty.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.