Siemens 6GF9001-1BF01 PROFIBUS Terminator
Request verified availability, condition, replacement risk review, packing options and courier lead time for 6GF9001-1BF01.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Siemens
- Primary Part Number
- 6GF9001-1BF01
- Product Type
- PROFIBUS Accessories
- Product Family
- Other series
- Manufacturer
- Siemens AG
- Country of Origin
- DE
- Model Function
- Passive PROFIBUS DP Bus Terminator (RS-485)
- Catalog Category
- Communication
- Operating Temp.
- -25 °C to +85 °C
6GF9001-1BF01 PROFIBUS Bus Terminator: Stop the Reflections, Restart the Line — Ships Today from Xiamen
Your PROFIBUS segment is down. Devices are dropping off the bus. The master is throwing BF (Bus Fault) or SF (System Fault) LEDs. You’ve already swapped cables, checked connectors, and power-cycled the rack — and the segment still won’t stabilize. Nine times out of ten, the culprit is a failed or missing bus terminator at one of the segment endpoints. The Siemens 6GF9001-1BF01 is the OEM-specified fix. We stock it in Xiamen and ship globally within 24 hours of order confirmation.
Every hour of unplanned downtime in a process plant or discrete manufacturing line carries a real cost — lost throughput, idle labor, expedited logistics, and management pressure. A passive component like a PROFIBUS terminator should never be the reason a line stays down for days. We built our inventory model around exactly this scenario: fast identification, fast dispatch, fast restart.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Value |
|---|---|
| Part Number (SKU) | 6GF9001-1BF01 |
| Manufacturer | Siemens AG |
| Product Family | SIMATIC NET PROFIBUS Accessories |
| Function | Passive PROFIBUS DP Bus Terminator (RS-485) |
| Applicable Standard | IEC 61158, EN 50170, PROFIBUS Specification |
| Connector Interface | DB9 Sub-D 9-pin, per PROFIBUS standard |
| Termination Resistance | 220 Ω line + 390 Ω pull-up / pull-down |
| Max Baud Rate Supported | 12 Mbit/s (full PROFIBUS DP range) |
| Operating Temperature | -25 °C to +85 °C |
| Protection Rating | IP20 (connector-mounted) |
| Power Requirement | None — fully passive device |
| Country of Origin | Germany |
| Compatibility | S7-300, S7-400, S7-1500, ET 200 series, SINAMICS, SCALANCE |
| Stock Status | ✔ Ready to Ship — Xiamen Warehouse |
Troubleshooting & Replacement Tips
Symptom pattern that points to a terminator failure: PROFIBUS master reports intermittent or permanent station loss on one or more slaves. Diagnostic buffer shows “Station failure” or “Bus error” events. Oscilloscope on the bus shows signal overshoot, ringing, or undefined idle-state voltage (should be >+0.2 V differential at idle).
Step-by-step replacement procedure:
- Step 1 — Isolate the segment. Put the PROFIBUS master into STOP mode or disconnect the DP interface. Do not hot-swap terminators on a live, high-speed segment — at 12 Mbit/s, even a 50 ms interruption will cause slave timeouts and may trigger safety interlocks downstream.
- Step 2 — Identify both segment endpoints. The 6GF9001-1BF01 must be installed at the first and last physical node on the cable — not the first and last in the address table. Trace the cable, not the address list. Common mistake: engineers terminate at the device with address 1 and address 126, but the physical cable routing may put address 45 at one end.
- Step 3 — Remove the failed terminator. Unscrew the DB9 connector from the device’s PROFIBUS port. Inspect the connector body for cracked housing, bent pins, or burn marks — these indicate a secondary fault (surge, mechanical impact) that may have damaged the device port as well.
- Step 4 — Install the 6GF9001-1BF01. Plug the new terminator directly onto the DB9 port of the endpoint device. Finger-tighten the locking screws — do not over-torque. The terminator is passive; no DIP switch, no address setting, no firmware. If your existing connector has a built-in termination switch (e.g., Siemens 6ES7 972-0BA52-0XA0), ensure that switch is set to ON at both endpoints and OFF at all intermediate nodes.
- Step 5 — Verify bus idle voltage before restart. With a multimeter set to DC, measure between pin 3 (RxD/TxD-P) and pin 8 (RxD/TxD-N) of any intermediate connector. At idle, you should read approximately +0.2 V to +1.0 V. A reading near 0 V or negative indicates missing or incorrect termination.
- Step 6 — Restart and monitor. Bring the master back online. Watch the diagnostic buffer for the first 5 minutes. If station loss events stop, the terminator was the root cause. If they continue, check cable shield continuity and connector pin crimps at intermediate nodes.
Common fault codes associated with termination issues:
- W#16#0005 — Station failure: Slave dropped off bus. First check termination at both ends before replacing the slave module.
- W#16#0006 — Bus error: Physical layer fault. Termination, cable break, or shield grounding issue.
- BF LED on ET 200M IM 153-x: Almost always a physical bus fault — termination or cable, not the IM module itself.
- SINAMICS G120 / S120 showing F01910 or A01900: PROFIBUS communication loss. Verify termination at the drive’s PROFIBUS port if it is the last device on the segment.
Configuration note — no addressing required: Unlike active repeaters or DP/PA couplers, the 6GF9001-1BF01 has zero configuration requirements. There is no DIP switch, no rotary address dial, no firmware version dependency. Install it and it works. This also means there is no compatibility risk across S7-300, S7-400, S7-1500, or any third-party PROFIBUS DP master.
Reliability in Harsh Conditions
Industrial environments do not forgive weak components. The 6GF9001-1BF01 is built to Siemens’ industrial-grade material and process standards, validated for the conditions found in steel mills, chemical plants, automotive body shops, and offshore platforms.
- Vibration resistance: Rated for continuous mechanical vibration per IEC 60068-2-6. The DB9 connector body uses a reinforced locking mechanism that maintains contact integrity even on machinery with high-frequency vibration profiles — CNC spindle cabinets, compressor skids, and conveyor drive panels.
- Thermal cycling: Qualified across -25 °C to +85 °C operating range. The passive resistor network inside uses metal-film resistors with low temperature coefficient (<100 ppm/°C), ensuring the 220 Ω termination impedance stays within specification across the full temperature range. Impedance drift is the silent killer of high-speed PROFIBUS segments — cheap aftermarket terminators fail here first.
- Humidity and condensation: Connector housing materials are rated for 95% relative humidity (non-condensing). For outdoor or high-humidity enclosures, pair with IP65-rated PROFIBUS connectors and ensure the cable entry gland is properly sealed — the terminator itself is IP20 as a connector-mounted device.
- EMI immunity: The integrated pull-up/pull-down resistor network provides a defined bus idle state that significantly improves noise immunity during inter-frame gaps. In high-EMI environments (near VFDs, large contactors, or welding equipment), this defined idle state prevents spurious start bits from corrupting frames — a failure mode that manifests as random CRC errors rather than clean station loss events.
- Long service life: Siemens specifies a design life consistent with SIMATIC NET infrastructure components. In practice, terminators in clean, stable environments last the life of the installation. Failures are almost always caused by mechanical damage (connector pulled at an angle), surge events, or contamination — not wear-out.
Global Express Logistics
Our dispatch hub is in Xiamen, Fujian, China — one of China’s primary export ports with direct daily freight connections to DHL, FedEx, and UPS international gateways.
- Order cut-off: Orders confirmed and paid before 14:00 CST ship same business day. Orders after cut-off ship next business day.
- DHL Express Worldwide: Europe (DE, NL, FR, IT, ES, PL) — 3 to 5 business days. Middle East (AE, SA, QA) — 3 to 4 business days. Southeast Asia (SG, MY, TH, VN) — 2 to 3 business days.
- FedEx International Priority: North America (US, CA, MX) — 3 to 5 business days. Australia and New Zealand — 4 to 6 business days. South America (BR, CL, CO) — 5 to 7 business days.
- Documentation provided: Commercial invoice, packing list, certificate of origin (Form E for ASEAN preferential tariff where applicable), and DHL/FedEx airway bill with real-time tracking number sent by email within 2 hours of dispatch.
- Customs classification: HS Code 8538.90 (parts for electrical apparatus for switching/protecting electrical circuits). We pre-fill all export documentation to minimize customs clearance delays at destination.
- Urgent freight options: For critical downtime situations, we can arrange same-day DHL On Demand Delivery or FedEx SameDay City where available. Contact us directly on WhatsApp for real-time freight options and cost.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.