Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

Siemens 6GK7343-5FA00-0XE0 PROFIBUS Communication Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for 6GK7343-5FA00-0XE0.

Exact part6GK7343-5FA00-0XE0 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part Number6GK7343-5FA00-0XE0 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 6GK7343-5FA00-0XE0

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
6GK7343-5FA00-0XE0
Product Type
PLC Communication Module
Series / Family
SIMATIC
Country of Origin
DE
Catalog Category
Communication
Operating Temp.
0 °C to +60 °C
Model confirmed for inquiry 6GK7343-5FA00-0XE0 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

6GK7343-5FA00-0XE0 In Stock — Every Hour of Downtime Costs You Money

Your S7-300 rack is dead. The PROFIBUS segment is silent. Production is stopped. You’ve already traced the fault to the CP 343-5 slot — the 6GK7343-5FA00-0XE0 is gone. You don’t need a datasheet right now. You need a module on a plane tonight.

We stock the Siemens 6GK7343-5FA00-0XE0 in Xiamen and ship globally via DHL Express and FedEx Priority. Most orders clear customs and land on your bench within 48–72 hours. While your procurement team is still filling out requisition forms, your replacement module is already in transit.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Value
Part Number 6GK7343-5FA00-0XE0
Module Family CP 343-5
Compatible Platform SIMATIC S7-300 (all standard CPU variants)
Communication Protocol PROFIBUS DP (Master Class 1 & 2, Slave) + FMS
Max PROFIBUS Baud Rate 12 Mbit/s
Physical Interface 9-pin Sub-D (RS-485)
Max DP Slaves 125 nodes per segment
S7 Routing Supported
FMS Services Supported
Configuration Tool STEP 7 V5.x / NCM S7 (TIA Portal: NOT supported)
Power Supply 5 VDC via S7-300 backplane bus
Operating Temperature 0 °C to +60 °C
Storage Temperature −40 °C to +70 °C
Dimensions (W×H×D) 40 × 125 × 120 mm
Weight ~230 g
Protection Rating IP20
Certifications CE, UL, cULus
HS Code 8537.10
Origin Germany
Stock Status ✅ Ready to Ship — Xiamen Warehouse

Troubleshooting & Replacement Tips

Ten years of field work on S7-300 PROFIBUS networks teaches you one thing: most CP 343-5 failures are not random. Here’s what actually happens and what to watch when you swap this module.

Common Failure Signatures:

  • BF LED solid red, no DP traffic: The module has lost its PROFIBUS configuration or the EEPROM has corrupted. Power-cycle alone won’t fix it — you need to re-download the hardware configuration from STEP 7.
  • SF LED flashing, BF off: One or more DP slaves are not responding. Before blaming the CP, check your PROFIBUS cable termination resistors at both ends of the segment. A missing 220 Ω terminator at 12 Mbit/s will take down the entire bus.
  • Module not recognized in rack (slot shows “???”): Backplane connector pins are bent or the module is seated in the wrong slot. The CP 343-5 must not occupy the CPU slot or the power supply slot. Any standard SM slot is valid.
  • Intermittent BF flicker at high baud rates: Cable length exceeds the 12 Mbit/s limit (max 100 m at 12 Mbit/s). Drop to 1.5 Mbit/s for longer runs or install a PROFIBUS repeater.
  • Module powers up but STEP 7 cannot go online: MPI/PROFIBUS address conflict. The CP 343-5 has its own PROFIBUS node address set in NCM S7 — verify it does not clash with any other master or slave on the segment.

Replacement Procedure — What You Must Not Skip:

  1. Power down the S7-300 rack completely. Do not hot-swap this module — the backplane bus does not support it.
  2. Note the PROFIBUS node address of the failed module before removal. It is stored in the STEP 7 hardware configuration, not on the module itself.
  3. Seat the new 6GK7343-5FA00-0XE0 in the same slot. Torque the front connector screws — a loose Sub-D connector at 12 Mbit/s causes intermittent faults that are nearly impossible to trace.
  4. Power up the rack. The module will boot with factory defaults — it has no memory of your previous configuration.
  5. Open STEP 7, go online, and perform a full hardware download to the CPU. The CPU will push the CP configuration automatically via the backplane.
  6. Verify BF LED goes off within 30 seconds of download completion. If it stays on, check that all DP slaves listed in your configuration are physically present and powered.
  7. If you are replacing a FA00 revision with a FA01 or FA02 revision: the hardware catalog entry in STEP 7 must be updated to match the new order number. Mismatched revision entries cause the CPU to reject the module.
  8. Run a PROFIBUS diagnostic in NCM S7 — confirm all slaves show “OK” status before handing back to operations.

Firmware Note: The 6GK7343-5FA00-0XE0 firmware is not field-upgradeable via a USB stick. Updates are applied through STEP 7 online functions. If your STEP 7 version is older than V5.4 SP5, check Siemens compatibility notes before attempting a firmware push.

Reliability in Harsh Conditions

The CP 343-5 was not designed for a climate-controlled server room. It was built for the plant floor — and the 6GK7343-5FA00-0XE0 reflects that in every design decision.

The module operates continuously from 0 °C to +60 °C without derating. In practice, we’ve seen these units running in poorly ventilated electrical cabinets where ambient temperatures regularly hit 55 °C during summer production peaks. The conformal coating on the PCB provides baseline protection against condensation and airborne contaminants — relevant in food processing, chemical, and coastal installations where humidity swings are routine.

Vibration resistance meets IEC 60068-2-6 test standards, which matters in press lines, compressor rooms, and any application where the control cabinet is mounted on or near moving machinery. The backplane connector is a mechanical locking design — it does not work loose under vibration the way terminal-block wiring can.

The IP20 rating means the module is protected against solid objects larger than 12 mm but is not sealed against liquids. If your cabinet has condensation issues or wash-down exposure, address the enclosure before blaming the module. We’ve seen perfectly good CP 343-5 units fail within weeks because the cabinet door seal was compromised.

EMC performance is certified to EN 61000-6-2 (industrial immunity) and EN 61000-6-4 (industrial emissions). In high-noise environments — VFD-heavy panels, large motor starters — ensure your PROFIBUS cable is properly shielded and the shield is grounded at one end only. Floating shields on long PROFIBUS runs are a common source of intermittent communication faults that look like module failures but aren’t.

Global Express Logistics

Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to international freight lanes via Xiamen Gaoqi International Airport and Xiamen Port.

Standard Express Routing:

  • Southeast Asia (SG, MY, TH, VN, ID): DHL Express — typically 1–2 business days door-to-door after dispatch.
  • Europe (DE, NL, FR, IT, PL, ES): DHL Express or FedEx International Priority — typically 3–5 business days. We pre-fill CN22/CN23 customs declarations with accurate HS codes (8537.10) to prevent customs holds.
  • North America (US, CA, MX): FedEx International Priority or DHL Express — typically 3–5 business days. We have experience with FDA/CBP entry requirements for industrial electronics.
  • Middle East (AE, SA, QA, KW): DHL Express — typically 2–4 business days. We handle Arabic commercial invoice requirements on request.
  • Australia & New Zealand: DHL Express — typically 3–4 business days.
  • South America (BR, CL, CO, PE): FedEx International Priority — typically 5–7 business days. Brazilian import documentation (NF-e equivalent) available on request.

Dispatch Timeline: Orders confirmed and paid before 14:00 CST are dispatched same business day. Orders after 14:00 CST ship next business day. You receive a tracking number within 2 hours of dispatch.

Packaging: Each module is individually wrapped in anti-static foam, placed in a rigid cardboard box, and double-boxed for international shipment. We do not use bubble wrap alone for fragile electronics — modules arrive in the same condition they left our warehouse.

Export Documentation: Commercial invoice, packing list, and certificate of origin are included with every shipment. FORM E (ASEAN-China FTA) available for qualifying destinations. Contact us before ordering if you need specific import documentation for your country’s customs authority.

Contact Information

For urgent stock inquiries, technical pre-sales questions, or shipping quotes:

© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.