Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
KURODA In Stock OK

KURODA RCS2413-01-D24L-Z Solenoid Valve

Request verified availability, condition, replacement risk review, packing options and courier lead time for RCS2413-01-D24L-Z.

Exact partRCS2413-01-D24L-Z RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandKURODA Part NumberRCS2413-01-D24L-Z ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ RCS2413-01-D24L-Z

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
KURODA
Primary Part Number
RCS2413-01-D24L-Z
Product Type
Solenoid Valve
Product Family
Other series
Country of Origin
Japan
Catalog Category
Valves & Positioners
Model confirmed for inquiry RCS2413-01-D24L-Z Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

RCS2413-01-D24L-Z: Line Down? This Valve Ships from Xiamen Before Your Next Shift Change

You didn’t come here to browse. A cylinder is locked, a filling station is idle, or a robot arm is faulted mid-cycle — and your maintenance team is standing around waiting for a part. The KURODA RCS2413-01-D24L-Z is a DC 24V direct-acting solenoid valve from the FONTAL series, R1/8 port, LED-equipped, Z-specification. It is physically stocked in our Xiamen warehouse. Not on order. Not inbound. On the shelf, tested, and ready to pack the moment your purchase order clears.

Every hour of unplanned downtime on a production line carries a real cost — whether that’s $500 or $50,000 depends on your process, but it’s never zero. The fastest way to close that gap is a verified replacement part that ships the same day. That’s the only thing this page is about.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification
Brand KURODA (黒田精工)
Full Part Number RCS2413-01-D24L-Z
Series FONTAL
Valve Function Direct-Acting Solenoid Valve (2/2 or 3/2 configuration)
Coil Voltage DC 24V
Port Size 01 = R1/8 (JIS B 0203 / ISO 228 thread)
Indicator L = LED energized indicator, integrated
Spec Suffix Z = Special specification variant
Actuation Mode Direct-acting — switches at zero differential pressure
PLC Compatibility DC 24V sink/source outputs (Siemens S7, Mitsubishi Q/FX, Omron CJ, AB CompactLogix)
Mounting Individual body or FONTAL manifold base
Country of Origin Japan
Availability ✔ In Stock — Ready to Ship, Xiamen

Troubleshooting & Replacement Tips

Ten years on the floor teaches you that solenoid valve failures cluster around four root causes. Here’s how to confirm you’re dealing with a dead RCS2413-01-D24L-Z — and how to swap it without creating a second fault.

Fault Pattern 1 — Coil failure (most common):
Measure resistance across the coil connector pins with the valve de-energized. A healthy FONTAL DC 24V coil reads 20–35 Ω at ambient temperature. Open circuit (OL) means the coil wire has burned through — typically from sustained over-voltage, a shorted output transistor on the PLC card, or moisture ingress into the connector. Near-zero resistance means a shorted coil. Either way, the unit is unserviceable. Order the replacement before you pull the failed valve — you want zero gap between removal and reinstallation.

Fault Pattern 2 — Spool seizure (mechanical):
Coil tests good, PLC output is confirmed active, LED lights — but the actuator doesn’t move. The spool is stuck. Root cause is almost always contaminated air supply: water carryover from a failed dryer, oil mist from an over-lubricated FRL, or fine particulate from a degraded filter element. Before installing the replacement, drain and inspect the air preparation unit. Flush the supply line. If you skip this step, the new valve will seize within weeks.

Fault Pattern 3 — LED on, no actuation (diagnostic trap):
The L-suffix LED confirms coil energization only. It does not confirm spool movement or downstream flow. If the LED is lit and the actuator is still faulted, check: (a) exhaust port blocked by contamination or incorrect back-pressure, (b) downstream restriction in tubing or fitting, (c) actuator mechanical fault independent of the valve. Disconnect the output port and verify free air flow before condemning the valve.

Fault Pattern 4 — Intermittent switching:
The FONTAL coil draws approximately 0.5–1.0 W at DC 24V. If the PLC output card is loaded near its current limit, or if the supply rail drops under load, coil voltage at the valve terminal can fall below the minimum pull-in threshold. Measure voltage at the connector under operating conditions — anything below 21.6V DC is suspect. Dedicated wiring from a properly sized 24V supply resolves this without touching the valve.

Step-by-step replacement procedure:

  1. Isolate the pneumatic circuit upstream. Close the isolation valve and exhaust residual pressure through the manual override or bleed port. Verify zero pressure with a gauge — do not rely on the PLC interlock alone.
  2. Force the PLC output channel OFF and lock it out per your site LOTO procedure. Confirm the LED is extinguished.
  3. Disconnect the electrical connector. If the connector shows corrosion or heat discoloration, replace it along with the valve — a degraded connector will cause the same fault on the new unit.
  4. Remove the valve body from the manifold base or pipe fitting. Inspect the port threads and sealing faces. Clean any debris from the manifold port before installation.
  5. Install the RCS2413-01-D24L-Z. Torque body screws to KURODA specification — typically 0.5–0.8 N·m for R1/8 bodies. Do not use thread sealant on the electrical connector side.
  6. Reconnect the electrical connector. Force the PLC output ON in test mode and confirm the LED illuminates immediately.
  7. Restore air pressure gradually. Cycle the valve 10 times under PLC control. Confirm full actuator travel, correct end-of-stroke timing, and no leakage at port connections using soapy water or leak detection spray.
  8. Z-suffix configuration note: The Z designation indicates a special specification that may include modified flow characteristics, non-standard seal materials, or application-specific adjustments. If your original valve was specified with Z for a defined process reason, contact us before installation to confirm the replacement unit is the correct Z-specification for your application.

Reliability in Harsh Conditions

The FONTAL series was engineered for environments where a valve that merely meets datasheet specs isn’t enough. Production floors impose stresses that no laboratory qualification test fully replicates: sustained vibration from presses and conveyors, thermal cycling from cold morning startups to full-load heat soak, coolant mist and cutting fluid aerosols drifting across manifold banks, and the occasional pressure spike from a compressor that hasn’t been serviced on schedule.

The RCS2413-01-D24L-Z addresses these conditions through design choices that are invisible until you need them. The coil assembly is fully encapsulated — not just potted at the top, but sealed against moisture ingress from any direction. In food processing and beverage filling applications where washdown is routine, this is the difference between a valve that survives a year and one that fails in the third month. The encapsulation also provides mechanical protection for the coil windings against the micro-vibration that causes wire fatigue failures in cheaper alternatives over extended service periods.

The valve body material and internal geometry are selected for dimensional stability across the operating temperature range. Spool clearances that are correct at 20°C must remain correct at 60°C ambient — a requirement that eliminates many lower-cost alternatives from consideration in foundry, glass, and high-ambient-temperature process applications. KURODA’s manufacturing tolerances on the FONTAL series are tight enough that spool-to-bore clearance remains within specification across this range without requiring temperature compensation in the control logic.

Direct-acting design is a reliability feature, not just a specification checkbox. Pilot-operated valves require a minimum differential pressure to shift — typically 0.15–0.2 MPa. In circuits where back-pressure conditions occur during startup sequences, or where the actuator load varies enough to reduce differential pressure below the pilot threshold, pilot-operated valves fail silently and intermittently. The RCS2413-01-D24L-Z shifts at zero differential pressure. It works when the circuit is at equilibrium, when the downstream actuator is stalled, and when the supply pressure is recovering after a compressor fault. That predictability is what you need when you’re troubleshooting a fault at 2 AM.

The integrated LED indicator on the L-suffix variant is rated for the same environmental exposure as the valve body. It maintains visibility in direct sunlight and resists the vibration-induced failures that affect separate indicator lamps. On a multi-station transfer line or a large manifold bank, the ability to visually confirm valve states from a distance during a fault walk-down is a practical time-saver that compounds across every maintenance event over the valve’s service life.

Global Express Logistics

Our warehouse is in Xiamen, Fujian — a primary export hub with direct daily connections to DHL Express, FedEx International Priority, and UPS Worldwide Express. Stock is physically on our shelves. We do not drop-ship, we do not source on demand, and we do not quote lead times that depend on a supplier’s availability. When we say ready to ship, we mean the box is on the shelf and the label prints when your order confirms.

Dispatch schedule: Orders confirmed before 14:00 CST ship same business day. Orders confirmed after 14:00 CST ship the following business day. Export documentation — commercial invoice, packing list, HS code declaration, and certificate of origin — is prepared in parallel with packing. This eliminates the documentation delays that add 24–48 hours to shipments from suppliers who treat paperwork as an afterthought.

Estimated door-to-door transit times (express service):

  • Southeast Asia — Singapore, Thailand, Vietnam, Malaysia, Indonesia: 2–3 business days
  • Northeast Asia — South Korea, Japan, Taiwan: 2–3 business days
  • South Asia — India, Bangladesh, Pakistan: 3–5 business days
  • Middle East — UAE, Saudi Arabia, Qatar, Kuwait: 3–5 business days
  • Europe — Germany, Netherlands, UK, France, Poland, Italy: 3–5 business days
  • North America — USA, Canada, Mexico: 4–6 business days
  • Oceania — Australia, New Zealand: 3–5 business days
  • South America and Africa: 5–8 business days depending on destination customs clearance

Tracking numbers are issued within 2 hours of dispatch and sent to your contact email. For time-critical downtime situations, we can arrange priority booking on the next available outbound flight from Xiamen Gaoqi International Airport. Give us your deadline and we will work backward from it to confirm whether same-day or next-flight dispatch is achievable.

For destinations with complex import requirements, we can advise on documentation structure to support smooth customs clearance. Contact us before placing the order if your destination has known import restrictions on industrial components.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.