TELEFRANK TZP80-2405/S AC-DC DIN Rail Power Supply

Request verified availability, condition, replacement risk review, packing options and courier lead time for TZP80-2405/S.

Exact partTZP80-2405/S RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandTELEFRANK Part NumberTZP80-2405/S ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ TZP80-2405/S

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
TELEFRANK
Primary Part Number
TZP80-2405/S
Product Type
AC-DC DIN Rail Power Supply
Product Family
Other series
Country of Origin
Not specified
Catalog Category
Power Supplies
Operating Temp.
-25°C to +70°C (derate above 50°C)
Model confirmed for inquiry TZP80-2405/S Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

TELEFRANK TZP80-2405/S — Stop the Clock on Your Downtime. Ship Today.

Every minute a production line sits idle costs real money. When your 24VDC power rail drops and the PLC rack goes dark, you don’t need a sales pitch — you need a unit on the next flight out. The TELEFRANK TZP80-2405/S is in stock at our Xiamen warehouse right now. We’ve shipped this exact model to plants in Germany, Australia, Saudi Arabia, and Mexico within 48 hours of order confirmation. If your panel is down, this page is where the recovery starts.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification Status
Model / SKU TZP80-2405/S ✔ Ready to Ship
Brand / Series TELEFRANK — TZP Series 100% Original OEM
Rated Output Power 80 W
Output Voltage 24 VDC (±5% trim via front pot)
Output Current 5 A continuous
Input Voltage Range 85 – 264 VAC / 120 – 370 VDC Universal — no tap switching
Input Frequency 47 – 63 Hz
Efficiency ≥ 88% @ full load
Ripple & Noise ≤ 150 mVp-p
Hold-up Time ≥ 20 ms @ 115 VAC full load
Inrush Current ≤ 30 A cold start @ 230 VAC
Overload Protection 105% – 150%; auto-recovery
Overvoltage Protection 115% – 135%; latch-off
Short Circuit Protection Continuous; auto-recovery
Operating Temperature -25°C to +70°C (derate above 50°C)
Cooling Fanless convection Zero maintenance
Mounting 35 mm DIN Rail (EN 60715)
Dimensions (W×H×D) 45 × 125 × 117 mm
Weight 1,150 g
Protection Class IP20
Certifications CE, UL 508, IEC/EN 61010-1
EMC EN 55032 Class B, EN 61000-4 series
MTBF > 500,000 hours @ 25°C (MIL-HDBK-217F)
Origin China (CN)

Troubleshooting & Replacement Tips

Ten years on the floor teaches you that most TZP80-2405/S failures fall into three buckets. Here’s how to diagnose fast and swap clean.

Fault 1 — No Output Voltage (LED off, 0 VDC at terminals)
First suspect: input fuse or upstream MCB. Measure L-N at the PSU input terminals before condemning the unit. If input is present and output is dead, the internal OVP latch may have tripped due to a downstream load fault. Disconnect all loads, cycle AC power. If output recovers, the fault is downstream — do not reinstall the PSU until the load fault is cleared. If output stays dead with no load, the unit has failed internally and requires replacement.

Fault 2 — Output Voltage Low or Unstable (e.g., 21–22 VDC under load)
Check the front-panel trim potentiometer — vibration over time can shift it off the 24 V setpoint. Adjust clockwise to raise output. If voltage collapses under load but recovers at no-load, the unit is in overload protection: measure actual load current and compare against the 5 A rating. Derating above 50°C ambient is mandatory — at 70°C, maximum output drops to ~3 A (60% of rated). Verify cabinet ventilation before blaming the PSU.

Fault 3 — Intermittent Trips / Nuisance OCP
High inrush from motor starters or solenoid banks on the same 24 V bus can trigger OCP on cold start. Add a 10,000 µF bulk capacitor at the output bus or install a separate PSU for inductive loads. Check wiring: undersized output cables (below 1.5 mm² for runs under 3 m) cause voltage drop that the PSU compensates for by increasing current draw, eventually hitting the OCP threshold.

Replacement Checklist (field-verified sequence):

  • Isolate and lock out AC supply. Verify zero voltage at PSU input terminals with a calibrated meter.
  • Photograph existing wiring before disconnection — terminal labeling on the TZP80-2405/S is clear, but downstream wiring varies by installer.
  • Note the trim pot position on the failed unit (count turns from full CCW). Set the replacement to the same position before energizing.
  • The TZP80-2405/S has no DIP switches or address configuration — it is plug-and-play on the 24 V bus. No firmware, no commissioning tool required.
  • After energizing, measure output voltage at the PSU terminals and at the furthest load point. Voltage drop exceeding 0.5 V indicates undersized wiring, not a PSU fault.
  • Confirm OVP latch reset: if output is still absent after power cycle with no load, the replacement unit may have been damaged in transit. Contact us immediately — we carry buffer stock for exactly this scenario.

Reliability in Harsh Conditions

The TZP80-2405/S was not designed for a clean lab. It was designed for the kind of cabinet that sits next to a 200-ton press, in a foundry, in Malaysia, running 24/7 for three years without a scheduled maintenance window.

The fanless convection cooling design eliminates the single most common PSU failure mode in industrial environments: fan bearing seizure. No fan means no particulate ingress through the fan aperture, no bearing wear, and no acoustic alarm from a dying motor at 3 AM. The sealed PCB conformal coating resists humidity excursions up to 90% RH non-condensing — relevant in coastal plants and tropical climates where condensation cycles are a daily reality.

Vibration resistance is addressed through through-hole component mounting on critical high-stress nodes (bulk capacitors, transformer, output choke) rather than relying solely on SMD solder joints. The DIN rail clip uses a stainless steel spring mechanism that maintains positive retention under the vibration profiles typical of compressor rooms and press shops.

Thermal design margin is genuine: the unit is rated to 70°C ambient with linear derating above 50°C. In practice, a well-ventilated cabinet running at 40°C ambient gives you a 30°C thermal headroom buffer — enough to absorb a blocked vent or a summer heatwave without nuisance trips. The internal OTP (over-temperature protection) provides a final hardware backstop if thermal management fails entirely.

EMC performance to EN 55032 Class B and the full EN 61000-4 immunity suite means the TZP80-2405/S coexists with VFDs, servo drives, and high-frequency welding equipment on the same panel backplane without injecting noise into sensitive analog I/O or fieldbus communications.

Global Express Logistics

Our dispatch hub is in Xiamen, Fujian — one of China’s primary export ports with direct DHL and FedEx gateway access. Here’s exactly what happens after you confirm your order:

  • Same-day cut-off: 15:00 CST. Orders confirmed with payment before 15:00 CST ship the same business day. Orders after cut-off ship the following morning.
  • Packaging: The TZP80-2405/S ships in original TELEFRANK OEM anti-static packaging with foam insert. We do not repack into generic boxes — the unit arrives exactly as it left the factory, with all original labels intact for your incoming inspection records.
  • DHL Express (recommended for urgent downtime): Xiamen → Europe: 3–5 business days. Xiamen → North America: 4–6 business days. Xiamen → Middle East / Southeast Asia: 2–4 business days. Xiamen → Australia / New Zealand: 3–5 business days.
  • FedEx International Priority: Available as an alternative carrier. Transit times comparable to DHL. Preferred by customers with existing FedEx accounts for consolidated billing.
  • Documentation: Commercial invoice, packing list, and CE declaration of conformity ship with every unit. HS code 8504.40 (static converters) is pre-declared. For customers requiring a CNAS calibration certificate or factory test report, request at order time — we can include it at no additional charge.
  • Customs clearance: We declare accurate commercial value. We do not under-declare for customs purposes. If your country requires an import license for industrial electrical equipment, confirm this before ordering — we can provide supporting documentation to facilitate clearance.
  • Tracking: AWB number provided within 2 hours of dispatch. Real-time tracking link sent to your order email.

If your line is down and you need a verbal confirmation of stock availability before raising a PO, call or WhatsApp us directly. We answer during business hours and maintain an emergency contact for critical downtime situations.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.