Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Schneider Electric
Primary Part Number
BMXAMI0810
Product Type
Analog Input Module
Series / Family
Modicon M340
Manufacturer
Schneider Electric
Country of Origin
FR
Catalog Category
I/O Modules
Operating Temp.
0 °C to +60 °C
Warranty
12 months from date of shipment
Model confirmed for inquiry BMXAMI0810 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

BMXAMI0810: 8-Channel Per-Channel Galvanically Isolated Analog Input Module for Modicon M340 Control Architecture

The Schneider Electric BMXAMI0810 is a high-density analog signal acquisition module engineered for the Modicon M340 programmable automation controller platform. Occupying a single slot on any BMX-series backplane rack, it provides eight fully independent, galvanically isolated analog input channels capable of accepting voltage signals in the ±10 V and 0–10 V ranges, as well as current loop signals at 0–20 mA and 4–20 mA — all configurable per channel in software without hardware jumper changes. At 16-bit resolution with a conversion time of ≤10 ms per channel, the BMXAMI0810 delivers the measurement fidelity required for closed-loop process control in continuous manufacturing, utilities, and infrastructure applications.

Unlike non-isolated analog modules where a single ground fault can corrupt all channel readings simultaneously, the BMXAMI0810 implements per-channel galvanic isolation barriers. Each channel’s signal path is electrically decoupled from the backplane bus and from every other channel, eliminating ground loop currents that arise when field transmitters are referenced to different earth potentials across large plant installations. This architecture is particularly critical in petrochemical, power generation, and water treatment facilities where cable runs may span hundreds of meters and ground potential differences of several volts are common.

The module integrates natively with EcoStruxure Control Expert (formerly Unity Pro) for configuration, diagnostics, and calibration. Channel-level diagnostic data — including open-circuit detection, over-range, and under-range flags — is mapped directly into the M340 CPU’s I/O image table, enabling the application program to implement fault-tolerant control strategies without additional hardware. The BMXAMI0810 draws its operating power entirely from the M340 backplane, requiring no external 24 VDC auxiliary supply, which simplifies panel wiring and reduces potential failure points in the power distribution architecture.

📦 Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

Parameter Specification
Part Number BMXAMI0810
Manufacturer Schneider Electric
Platform Modicon M340 (BMX series)
Module Type Analog Isolated High-Level Input
Number of Channels 8 (fully independent)
Input Signal Ranges ±10 V, 0–10 V, 0–20 mA, 4–20 mA (per-channel software configurable)
Resolution 16-bit (65,536 counts)
Conversion Time ≤ 10 ms per channel (sequential scanning)
Isolation Type Galvanic isolation, channel-to-channel and channel-to-backplane
Isolation Voltage 1,500 V AC (channel-to-bus)
Input Impedance (Voltage) > 1 MΩ
Input Impedance (Current) 250 Ω (burden resistor integrated)
Accuracy ±0.1% of full scale at 25 °C
Temperature Drift ≤ 50 ppm/°C
Backplane Power Consumption ≤ 4.5 W (from M340 backplane, no external supply required)
Operating Temperature 0 °C to +60 °C
Storage Temperature -25 °C to +70 °C
Relative Humidity 5% to 95% non-condensing
Protection Rating IP20
Mounting BMXXBP0400 / 0600 / 0800 / 1200 backplane racks
Dimensions (H × W × D) 100 × 15 × 115 mm (single-slot form factor)
Weight ~500 g
Certifications CE, UL, cUL, IEC 61131-2, RoHS
Warranty 12 months from date of shipment

Hardware Logical Analysis

Per-Channel Isolation Architecture: The BMXAMI0810 implements individual isolation barriers using transformer-coupled or optocoupler-based galvanic separation on each of its eight signal paths. This means the analog front-end circuitry for each channel — including the input protection network, anti-aliasing filter, and sample-and-hold stage — operates on a floating reference independent of the module’s internal digital ground. The isolation barrier sustains 1,500 V AC between the field-side signal and the backplane bus, providing protection against transient overvoltages induced by nearby switching equipment, motor drives, or lightning-coupled surges on long cable runs.

16-Bit Sigma-Delta ADC Implementation: Signal digitization is performed by a sigma-delta analog-to-digital converter architecture. Unlike successive-approximation ADCs, sigma-delta converters inherently integrate the input signal over multiple clock cycles, providing first-order noise shaping that attenuates high-frequency interference. The oversampling ratio is selected to achieve an effective noise-free resolution of approximately 15 bits under typical industrial noise conditions, with the full 16-bit count range (0–65,535) mapped to the configured engineering unit span. This makes the module suitable for precision temperature measurement via 4–20 mA transmitters where 0.1°C resolution is required across a 200°C span.

EMC Design and Filtering: The module’s PCB layout incorporates a multi-layer ground plane strategy that separates analog signal traces from digital clock lines. Input terminals are protected by transient voltage suppression (TVS) diodes rated for IEC 61000-4-5 surge immunity at 1 kV (line-to-line) and 2 kV (line-to-earth). A second-order RC anti-aliasing filter with a cutoff frequency of approximately 50 Hz is applied at each channel input, attenuating power-line frequency interference and its harmonics before the ADC sampling stage. The module carries CE marking for EMC compliance under EN 61131-2, confirming conformance to conducted and radiated emission limits as well as immunity to electrostatic discharge (ESD), fast transients (EFT/Burst), and radiated RF fields.

Backplane Communication Protocol: The BMXAMI0810 communicates with the M340 CPU via the X-Bus backplane protocol, a synchronous serial interface operating at a fixed clock rate determined by the CPU module. The I/O exchange is deterministic: the CPU’s task scheduler initiates a backplane scan at the start of each task period, and the BMXAMI0810 responds with its current channel data within the guaranteed scan window. This ensures that analog values presented to the application program are coherent — all eight channels are sampled within the same conversion cycle, eliminating inter-channel time skew that would otherwise introduce errors in ratio-metric calculations or differential measurements.

Open-Wire and Over-Range Detection: For current loop inputs configured at 4–20 mA, the module continuously monitors whether the measured current falls below a configurable threshold (typically 3.6 mA). A current below this threshold indicates a broken wire or transmitter power failure, and the module sets a channel-level diagnostic bit in the I/O image. The application program can read this bit and execute a predefined fault response — such as switching to a backup sensor, activating an alarm, or holding the last valid value — without requiring any additional hardware relay or monitoring circuit.

System Integration Benefits

  • Zero-jumper channel configuration: All eight channels are configured entirely in EcoStruxure Control Expert software. Switching a channel between voltage and current mode, or changing the input range, requires no physical access to the module or terminal block, reducing commissioning time and eliminating the risk of misconfiguration from incorrect jumper placement.
  • Deterministic I/O scan timing: The X-Bus backplane protocol guarantees that analog data is refreshed at every CPU task cycle. For a MAST task configured at 10 ms, all eight channel values are updated within that period, enabling the application to implement PID control loops with consistent sample intervals — a prerequisite for stable derivative action in fast-response processes.
  • Channel-level diagnostic transparency: Over-range, under-range, open-circuit, and module-level fault flags are mapped to dedicated bits in the I/O image table. These bits are accessible to the application program, SCADA systems via Modbus TCP, and the EcoStruxure Control Expert diagnostic viewer simultaneously, providing multi-layer fault visibility without additional programming overhead.
  • Single-slot density: Eight isolated analog inputs in a 15 mm wide single-slot module maximizes rack utilization. A 12-slot BMXXBP1200 rack can accommodate up to 11 BMXAMI0810 modules (one slot reserved for the CPU), providing 88 isolated analog input channels in a single rack — a density that reduces panel footprint and inter-rack wiring complexity in large process control installations.
  • No external power supply required: The module draws all operating power from the M340 backplane bus. This eliminates the need for a dedicated 24 VDC auxiliary supply circuit, associated fusing, and wiring, reducing both bill-of-materials cost and potential failure modes in the power distribution architecture.
  • Seamless firmware and software lifecycle: The BMXAMI0810 is fully supported in all versions of EcoStruxure Control Expert from v11.0 onward. Module firmware updates, when issued by Schneider Electric, are applied through the software without removing the module from the rack, minimizing maintenance downtime.
  • Mixed-signal coexistence: The per-channel isolation architecture allows the BMXAMI0810 to accept signals from transmitters referenced to different field ground potentials within the same module. This is essential in installations where sensors are distributed across multiple process areas with separate earthing systems, a scenario that would cause measurement errors or ground fault trips in non-isolated modules.
  • IEC 61131-2 compliance for global deployment: The module meets the environmental, electrical, and functional requirements of IEC 61131-2, the international standard for programmable controllers. This certification is recognized by engineering approval bodies in the EU, North America, and Asia-Pacific, simplifying the documentation and approval process for projects subject to regulatory review.

Quality Assurance & Global Logistics

Every BMXAMI0810 unit supplied by siemensplc.com is sourced as genuine Schneider Electric original product. Units are stored in a climate-controlled warehouse in Xiamen, China, maintained at controlled temperature and humidity to preserve component integrity. Prior to dispatch, each module undergoes a multi-point inspection protocol: label authenticity verification against Schneider Electric’s current part marking standards, visual inspection of the PCB connector and terminal block for mechanical damage, and a power-on functional check where test equipment is available.

Packaging follows IEC 60068-2 transport vibration and shock guidelines. Modules are individually sealed in anti-static polyethylene bags, placed in foam-lined inner cartons, and packed in double-wall corrugated outer cartons rated for international air freight handling. For orders of five or more units, a packing list with individual serial numbers is included to support traceability requirements in regulated industries.

Logistics from Xiamen are executed via DHL Express, FedEx International Priority, and UPS Worldwide Express, with typical transit times of 3–5 business days to Europe, 4–6 business days to North America, and 2–4 business days to Southeast Asia. For bulk orders, sea freight via Xiamen Yuanhai International Container Terminal is available with full container load (FCL) and less-than-container load (LCL) options. All shipments are covered by cargo insurance, and tracking numbers are provided within 24 hours of dispatch. Export documentation — including commercial invoice, packing list, and certificate of origin — is prepared in compliance with the destination country’s customs requirements.

A 12-month warranty is provided from the date of shipment. Warranty coverage includes defects in materials and workmanship under normal operating conditions as defined by Schneider Electric’s published environmental specifications. Warranty claims are processed within 5 business days of receipt of the returned unit, with replacement or credit issued upon confirmation of the defect.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.