ABB 1SDA063550R1 SCR Auxiliary Contact — Stop the Clock on Your Downtime
Every minute your switchgear is offline, production bleeds money. A failed auxiliary contact on your SACE Emax 2 breaker kills position feedback to your PLC, locks out your interlock logic, and grounds your entire distribution panel. The ABB 1SDA063550R1 SCR module is the exact OEM replacement you need — and we have it on the shelf in Xiamen, ready to move today.
We don’t deal in compatible substitutes or grey-market pulls. This is a genuine ABB part, sourced through verified channels, pre-inspected before it leaves our warehouse. If your maintenance window is measured in hours, not days, you’re in the right place.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Part Number | 1SDA063550R1 ✅ Ready to Ship |
| Manufacturer | ABB |
| Series | SACE Emax 2 |
| Module Type | SCR — Auxiliary / Signaling Contact |
| Compatible Frames | E1.2, E2.2, E4.2, E6.2 |
| Rated Voltage | ≤ 250 V AC/DC |
| Rated Current | ≤ 6 A |
| Contact Material | Silver-Nickel Alloy (AgNi) |
| Mounting | Plug-in snap-fit, tool-free |
| Operating Temperature | -25°C to +70°C |
| Protection Class | IP20 (installed) |
| Standards | IEC 60947-2, CE Marked |
| Country of Origin | Italy |
| Weight | ~120 g |
| Stock Status | ✅ In Stock — Ships within 24 hrs |
Troubleshooting & Replacement Tips
Common failure symptoms for 1SDA063550R1:
- PLC digital input for breaker position (Q0.x / I0.x) shows no signal change on OPEN/CLOSE command — contact weld or open-circuit failure in the SCR module.
- SCADA reports persistent “breaker status unknown” or “feedback timeout” alarm — cam follower worn, contact no longer actuating.
- Interlock logic refuses to permit bus transfer — position feedback stuck in last state, preventing permissive signal.
- Intermittent contact bounce causing spurious trip signals in relay logic — silver alloy surface pitting after high-cycle operation.
Replacement procedure (field-verified steps):
- De-energize and isolate. Rack the Emax 2 breaker to the TEST or DISCONNECTED position. Verify zero-energy state with a calibrated voltage tester on the auxiliary circuit terminals before touching anything.
- Identify the accessory slot. Refer to ABB Doc. 1SDH001000R0002 (Emax 2 Accessory Combination Chart) to confirm the SCR slot position on your specific frame size. On E1.2/E2.2, the SCR typically occupies the right-side accessory bay.
- Remove the failed module. Press the release tab and pull the module straight out — no tools required. Inspect the slot for debris or carbon tracking before inserting the replacement.
- Insert 1SDA063550R1. Align the module with the slot guide rails and push firmly until the retention clip audibly clicks. Do not force — misalignment will damage the cam follower on first operation.
- Verify mechanical actuation. Manually operate the breaker (TEST position) and confirm the auxiliary contact switches state. Use a continuity tester on the terminal block before reconnecting control wiring.
- Restore wiring and test under load. Reconnect the auxiliary circuit wiring (shielded twisted-pair recommended for runs >10 m). Perform a full OPEN/CLOSE cycle from the control panel and verify PLC/SCADA feedback registers correctly.
- No firmware or address configuration required. The SCR module is a purely mechanical/electrical device — no DIP switches, no addressing, no firmware. Plug in and verify continuity. That’s it.
Critical compatibility check: This module is Emax 2 only. It is NOT interchangeable with first-generation SACE Emax accessories. The mechanical interface changed between generations. Verify your breaker nameplate reads “Emax 2” before ordering.
Reliability in Harsh Conditions
Industrial switchgear rooms are not clean environments. Vibration from nearby motors and compressors, ambient temperatures pushing 55°C in summer, humidity cycling from condensation during plant shutdowns — the 1SDA063550R1 is built to handle all of it without complaint.
ABB’s AgNi silver-nickel contact material maintains stable contact resistance across thousands of switching cycles, resisting the micro-welding and oxidation that kills cheaper contact materials in high-humidity environments. The snap-fit housing is rated to withstand the vibration profiles typical of MCC installations per IEC 60068-2-6, so you won’t see nuisance contact bounce from panel vibration alone.
Operating range of -25°C to +70°C covers everything from unheated outdoor switchgear enclosures in northern climates to hot process areas in petrochemical plants. IP20 protection when installed prevents accidental contact with live parts during panel maintenance — a non-negotiable in facilities with strict arc-flash programs.
Mechanical endurance is rated in line with the Emax 2 breaker’s own operating cycle life — typically exceeding 10,000 operations under standard duty. For high-cycle applications like bus-tie breakers that operate multiple times per day, plan a proactive replacement interval and keep a spare on the shelf. The cost of one unplanned outage dwarfs the price of a spare module.
Global Express Logistics
Our warehouse is located in Xiamen, China — one of the country’s primary export hubs with direct access to DHL, FedEx, and UPS international gateways. Orders confirmed before 15:00 CST ship same day. Here’s what the timeline looks like from your purchase order to your panel room:
- Day 0 (Order Confirmed): Part pulled from shelf, inspected, packed in anti-static protective packaging. Shipping label generated and handed to carrier by end of business.
- Day 1–2 (In Transit — Asia/Pacific): DHL Express or FedEx International Priority clears Xiamen customs. Tracking number sent to your email immediately upon pickup scan.
- Day 2–3 (Delivery — Southeast Asia, Japan, Korea, Australia): Most regional destinations receive within 2–3 business days door-to-door.
- Day 3–5 (Delivery — Europe, Middle East, Americas): Transatlantic and long-haul routes typically deliver within 3–5 business days depending on destination customs clearance speed.
For genuinely critical situations — plant shutdown with a hard restart deadline — contact us directly on WhatsApp before placing the order. We can confirm real-time stock, arrange priority pick, and coordinate with the carrier for earliest possible flight booking. We’ve done it before. We’ll do it again.
All shipments include a commercial invoice, packing list, and country-of-origin certificate. For projects requiring an ABB Declaration of Conformity or test documentation, request it at time of order and we’ll include it in the shipment package.
Contact Information
📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.