Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
ABB In Stock OK

ABB DSSB140 48980001-P DCS Battery Backup Unit – Advant MOD 300

Request verified availability, condition, replacement risk review, packing options and courier lead time for 48980001-P.

Exact part48980001-P RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandABB Part Number48980001-P ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 48980001-P

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
ABB
Primary Part Number
48980001-P
Product Type
DCS Battery Backup Unit
Series / Family
Advant
Manufacturer
ABB
Country of Origin
SE
Catalog Category
DCS & Safety Modules
Operating Temp.
0 °C to +55 °C
Warranty
12 months from dispatch date
Model confirmed for inquiry 48980001-P Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

ABB DSSB140 48980001-P – Rack-Integrated Battery Backup Unit for Advant / MOD 300 Distributed Control Systems

The DSSB140, ordered under ABB reference 48980001-P, is a rack-mount battery backup unit (BBU) engineered specifically for the ABB Advant Controller and MOD 300 distributed control system platform. Its primary function is to sustain controller CPU operation, volatile memory retention, and active I/O communication during mains power interruptions — without any scan-cycle disruption. In continuous-process industries where an unplanned controller restart translates directly into production loss, regulatory incident, or equipment damage, the DSSB140 is a non-negotiable component of the power architecture.

Unlike generic UPS solutions placed upstream of the rack, the DSSB140 operates at the backplane level. It monitors the internal DC bus voltage of the Advant / MOD 300 rack and executes a sub-millisecond switchover to battery output upon detecting a dropout event. This architecture eliminates the propagation delay inherent in external UPS systems and ensures that the controller’s real-time operating cycle — typically 10 ms to 100 ms scan intervals — is never interrupted by a power transient.

📩 Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

Manufacturer ABB
Part Number DSSB140
Order Reference 48980001-P
Module Classification Battery Backup Unit (BBU)
Compatible Platform ABB Advant Controller / MOD 300 DCS
Monitored Bus Internal DC backplane power rail
Switchover Mechanism Automatic, sub-millisecond, transparent to controller scan cycle
Battery Chemistry Sealed lead-acid or NiCd (confirm per rack BOM revision)
Nominal Backup Voltage 24 VDC (backplane rail; refer to ABB system manual for tolerance band)
Backup Duration Sufficient to bridge transient mains interruptions; duration dependent on rack load profile
Recharge Mode Automatic float charge upon mains restoration
Mounting Form Factor Direct rack-mount, Advant / MOD 300 backplane slot
Operating Temperature 0 °C to +55 °C
Storage Temperature -20 °C to +70 °C
Relative Humidity 5% to 95% RH, non-condensing
Approx. Weight 500 g
Certifications CE; full compliance list per ABB product documentation
Warranty 12 months from dispatch date
Country of Origin Germany

Hardware Logical Analysis

The DSSB140 is designed around a voltage-threshold detection circuit that continuously samples the Advant / MOD 300 internal DC bus. When bus voltage drops below a defined threshold — typically within the range of 18–20 VDC for a 24 VDC nominal rail — the module’s internal MOSFET switching stage activates the battery discharge path. The transition is governed by a diode-OR topology at the output stage, which prevents back-feed from the battery into the mains supply path and eliminates the need for mechanical relay switching. This solid-state architecture is the primary reason the switchover is transparent to the controller’s scan cycle.

From an EMC standpoint, the DSSB140 incorporates LC filtering on both the input monitoring circuit and the battery output path. This suppresses conducted emissions generated during the switchover transient and prevents high-frequency noise from coupling into the backplane signal lines — a critical design consideration in environments with variable-frequency drives, large motor contactors, or thyristor-controlled rectifiers operating in proximity to the DCS rack.

The battery charge management circuit uses a two-stage profile: bulk charge at constant current to restore capacity rapidly after a discharge event, followed by float charge at a reduced voltage to maintain full charge without accelerating electrolyte degradation. This extends battery service life beyond the 3–5 year baseline achievable with simpler trickle-charge designs. The module also includes a battery health indicator output that can be wired to the Advant system’s diagnostic bus, enabling predictive maintenance scheduling without physical inspection of the module.

Thermal management is passive: the module’s aluminum housing acts as a heat spreader, conducting heat from the power electronics to the rack enclosure. No forced-air cooling is required within the module itself, which eliminates a potential failure mode in high-dust industrial environments where fan filters require frequent maintenance.

System Integration Benefits

  • Zero scan-cycle interruption: Sub-millisecond switchover ensures the controller’s real-time task scheduler sees no power event; process variables and PID outputs remain continuous through the transition.
  • Volatile memory retention: CPU RAM and I/O image tables are sustained at full operating voltage during backup, preserving process state without requiring a warm restart sequence.
  • Backplane-level protection scope: Unlike upstream UPS devices, the DSSB140 protects against internal rack power supply failures in addition to mains interruptions — a failure mode that external UPS systems cannot address.
  • Automatic recharge with no operator intervention: Float charge mode activates immediately upon mains restoration; no manual reset or charge initiation is required, reducing operator workload during recovery.
  • Diagnostic transparency: Battery health status output integrates with the Advant system diagnostic bus, enabling condition monitoring from the operator station without physical access to the rack.
  • Drop-in form factor: Identical mechanical envelope and backplane connector pinout to OEM specification; no rack modification, firmware update, or configuration change required for replacement.
  • Lifecycle extension for legacy DCS: Enables continued operation of Advant / MOD 300 installations beyond ABB’s standard hardware support window, deferring costly platform migration projects.
  • EMC-hardened output path: LC filtering on the battery discharge circuit prevents noise injection into backplane signal lines during switchover, maintaining signal integrity for analog I/O modules operating at ±10 VDC or 4–20 mA ranges.
  • Thermal reliability in harsh environments: Passive aluminum housing dissipates heat without fans, eliminating a maintenance-intensive failure mode in high-particulate industrial environments such as cement, mining, and chemical processing.
  • Broad application compatibility: Validated for use in oil and gas, power generation, chemical, pulp and paper, and water treatment DCS installations operating on the Advant / MOD 300 platform.

Quality Assurance & Global Logistics

Every DSSB140 unit dispatched from our Xiamen, China facility is sourced through verified supply channels with full part-number and revision traceability. New OEM units are inspected against ABB marking standards and packaging integrity upon receipt. Refurbished units undergo a complete charge/discharge cycle test, load verification at rated output current, and insulation resistance measurement before being listed as available stock. Test reports and certificates of conformance are available on request for MRO and EPC procurement workflows.

Packaging is specified for long-haul international freight: each unit is sealed in an anti-static bag, cushioned in a foam-lined carton, and shipped with a humidity indicator card. For temperature-sensitive battery chemistry, cold-chain handling instructions are included where applicable. Incoterms DDP and DAP are both supported, with freight forwarding partnerships covering major industrial hubs in Europe, Southeast Asia, the Middle East, and the Americas. Standard dispatch is 1–3 business days from order confirmation; expedited same-day dispatch is available for critical shutdown scenarios — contact us directly to arrange.

All units carry a 12-month warranty from dispatch date, covering functional defects under normal operating conditions. Warranty claims are processed with a target response time of 48 hours and replacement dispatch within 5 business days.

Contact Information

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
📍 Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.