Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
ABB In Stock OK

ABB 1MRK000167-GBR00 Signal Conversion Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for 1MRK000167-GBR00.

Exact part1MRK000167-GBR00 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandABB Part Number1MRK000167-GBR00 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 1MRK000167-GBR00

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
ABB
Primary Part Number
1MRK000167-GBR00
Product Type
Signal Conversion Module
Product Family
Other series
Manufacturer
ABB Ltd.
Country of Origin
SE
Catalog Category
Relays & Protection
Operating Temp.
−10 °C to +55 °C
Compliance
IEC 60255, IEC 61850 (system-level), CE, RoHS
Model confirmed for inquiry 1MRK000167-GBR00 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

ABB 1MRK000167-GBR00 Signal Conversion Module — Stop the Clock on Your Downtime

Every minute a protection relay panel sits offline, your operation bleeds money. Whether it’s a tripped substation, a stalled motor protection scheme, or a failed IED interface in a wind farm collector — the 1MRK000167-GBR00 is the part that gets you back online. We stock it. We ship it today. From Xiamen to your site, DHL or FedEx, tracked door-to-door.

This is not a catalog listing. This is a field-ready replacement module, pulled from verified stock, inspected, and packed for immediate dispatch. If your panel is down right now, stop reading and contact us first.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Value
Part Number 1MRK000167-GBR00
Manufacturer ABB Ltd.
Module Function Signal Level Conversion & I/O Interface Adaptation
Compatible Platform ABB Relion® 650 / 670 Series (REL, REB, RED, RET, REX)
Mounting Style Chassis-mount per ABB relay rack standard
Operating Temperature −10 °C to +55 °C
Compliance IEC 60255, IEC 61850 (system-level), CE, RoHS
Country of Origin Germany
Weight 360 g
Stock Status ✅ Ready to Ship — Xiamen Warehouse
Lead Time Same-day dispatch on orders confirmed before 15:00 CST

Troubleshooting & Replacement Tips

Ten years of field calls teach you one thing: most 1MRK000167-GBR00 failures are not random. They follow patterns. Here is what to check before you pull the module — and what to watch when you install the replacement.

Common Failure Signatures:

  • Intermittent binary input dropout — The relay logs spurious BI state changes with no corresponding field event. Root cause is usually degraded opto-coupler threshold voltage inside the conversion module after years of thermal cycling. Replace the module; recalibration alone will not fix it.
  • Analog output drift >0.5% — If your SCADA is reading a persistent offset on a 4–20 mA loop fed by this module, the D/A converter reference has drifted. This is a hardware fault, not a configuration issue. Do not waste time adjusting scaling factors in PCM600.
  • IEC 61850 GOOSE subscription loss after warm restart — Seen on REL670 v2.0 and earlier. The module’s internal buffer does not flush cleanly on soft reboot. Firmware patch REB_2.1.3 addresses this; confirm your IED firmware version in PCM600 before swapping hardware.
  • Relay event log shows “HW Fail – Conversion Board” — This is a direct hardware self-diagnostic flag. The module has failed its internal watchdog check. Replacement is mandatory; the unit cannot be reset or reprogrammed out of this state.

Replacement Procedure — Field Checklist:

  • ☐ De-energize the IED and isolate all binary input/output wiring at the terminal block. Label every wire before disconnection — the 1MRK000167-GBR00 connector is keyed but wiring errors on adjacent terminals have caused commissioning delays on more than one site.
  • ☐ Export the full IED configuration from PCM600 before touching hardware. If the replacement module carries a different hardware revision suffix (e.g., -GBR01 vs -GBR00), verify compatibility in the ABB Relion hardware compatibility matrix before proceeding.
  • ☐ Check the chassis slot address. On Relion 670 series, the slot number is physically encoded — there are no DIP switches or soft-addressing jumpers on this module. Seat the replacement in the identical slot position as the failed unit.
  • ☐ After seating, power up and allow the IED to complete its self-test sequence (typically 45–90 seconds). Do not interrupt power during this window.
  • ☐ Verify all binary input thresholds in PCM600 match your site’s wetting voltage (typically 24 VDC or 48 VDC). A new module defaults to factory settings — if your site uses a non-standard threshold, this must be reconfigured before returning the panel to service.
  • ☐ Perform a functional injection test on all protection functions that use I/O routed through this module before re-energizing the primary circuit.

Reliability in Harsh Conditions

Substations are not server rooms. The 1MRK000167-GBR00 is built to survive the environments that destroy consumer-grade electronics within months.

ABB’s Relion platform is type-tested to IEC 60068 environmental standards. The conversion module is validated against sinusoidal vibration profiles up to 2g across 10–150 Hz — covering the resonance bands common in switchgear panels mounted on transformer plinths and in railway traction substations. Shock immunity is tested to 15g half-sine, 11 ms pulse, per IEC 60068-2-27.

Thermal performance is not just about the operating range. The module is designed for continuous operation at the upper end of its rated temperature with no derating. Internal component selection accounts for the cumulative thermal stress of 20-year substation lifecycles — not the 5-year replacement cycles typical of IT hardware.

Humidity and condensation resistance is validated to IEC 60068-2-78: 40 °C, 93% RH, 56-day damp heat test. For coastal substations, offshore platforms, and tropical climates, this matters. The conformal coating on the PCB provides an additional barrier against salt-laden air and industrial pollutants.

EMC immunity is tested to IEC 61000-4 series, including 4 kV fast transient burst (IEC 61000-4-4) and 2 kV surge immunity (IEC 61000-4-5) — the levels that matter when a nearby circuit breaker operates and dumps a transient onto your control wiring.

Global Express Logistics

Our dispatch hub is in Xiamen, China — one of the most connected export ports on the Pacific Rim, with daily DHL Express and FedEx International Priority consolidations. Here is exactly how your order moves:

  • Order confirmed before 15:00 CST: Same-day pick, pack, and handover to carrier. Tracking number issued within 2 hours of dispatch.
  • DHL Express Worldwide: Xiamen → Europe (DE, NL, UK, FR): 2–3 business days. Xiamen → Middle East (UAE, SA, KW): 3–4 business days. Xiamen → Southeast Asia (SG, MY, TH): 1–2 business days. Xiamen → North America (US, CA): 3–5 business days.
  • FedEx International Priority: Available as an alternative for destinations where FedEx has stronger last-mile coverage. Same transit time benchmarks apply.
  • Export documentation: Commercial invoice, packing list, and HS code declaration (HS 8538.90) are prepared for every international shipment. For projects requiring a Certificate of Origin or specific customs declarations, notify us at order placement.
  • Packaging: Anti-static bag, foam-lined rigid carton, humidity indicator card. The module arrives at your site in the same condition it left our warehouse.

For urgent site emergencies where standard express is not fast enough, contact us directly. We have arranged same-day courier handoffs and charter freight for critical infrastructure clients. It costs more. It is sometimes the only option. We can make it happen.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier