Allen-Bradley 1746-A13/B PLC Chassis
Request verified availability, condition, replacement risk review, packing options and courier lead time for 1746-A13/B.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Allen-Bradley
- Primary Part Number
- 1746-A13/B
- Product Type
- PLC Chassis
- Series / Family
- SLC 500
- Manufacturer
- Allen-Bradley / Rockwell Automation
- Country of Origin
- US
- Catalog Category
- PLCs & Controllers
- Operating Temp.
- 0 °C to 60 °C
Allen-Bradley 1746-A13/B — Stop the Clock on Your Downtime. Ship Today.
Every minute your line sits idle, the losses compound. A failed SLC 500 chassis doesn’t wait for procurement cycles — and neither do we. The Allen-Bradley 1746-A13/B 13-slot chassis is physically verified, bench-checked, and staged for same-day dispatch from Xiamen. Whether you’re running an automotive body shop, a bottling line, or a water treatment station, this is the part that gets your system back online before the next shift starts.
We stock this chassis specifically because it’s one of the most failure-prone mechanical components in aging SLC 500 installations. Backplane connector fatigue, slot guide wear, and power bus degradation are real failure modes — and when they hit, you need a replacement in hand, not a lead-time quote.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Part Number | 1746-A13/B ✅ Ready to Ship |
| Series | SLC 500 |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Chassis Slots | 13 total (1 processor + 12 I/O) |
| Backplane Current — 5 VDC | 10 A |
| Backplane Current — 24 VDC | 3 A |
| Compatible Processors | SLC 5/01, 5/02, 5/03, 5/04, 5/05 (1747-L5xx series) |
| Power Supply Compatibility | 1746-P1, P2, P3, P4, P5, P6, P7 |
| Mounting Orientation | Horizontal or vertical panel mount |
| Operating Temperature | 0 °C to 60 °C |
| Storage Temperature | −40 °C to 85 °C |
| Relative Humidity | 5 % to 95 % non-condensing |
| Weight | 2.55 kg |
| Revision | Series B (improved backplane, enhanced EMI shielding) |
| HS Code | 8537.10 |
| Stock Status | ✅ In Stock — Xiamen Warehouse |
Troubleshooting & Replacement Tips
Swapping a 1746-A13/B is not a plug-and-play operation if you skip the pre-checks. Here’s what actually matters on the floor:
1. Backplane Connector Inspection Before Insertion
Before seating any module into the replacement chassis, visually inspect every backplane connector with a flashlight. Bent or oxidized pins on the new chassis — even from storage — will cause intermittent faults that look like processor or I/O module failures. Use a clean, dry brush to clear any debris from the connector rows.
2. Power Budget Recalculation
The 1746-A13/B backplane supplies 10 A at 5 VDC and 3 A at 24 VDC. Before transferring your existing module set, add up the 5 V and 24 V draw from every module in your BOM. Analog modules (1746-NI4, NO4I) and communication cards (1747-SDN, 1747-SCNR) are the heaviest consumers. If your total draw is within 85 % of the backplane rating, you’re safe. Above that, consider redistributing modules or upgrading to a higher-rated power supply (1746-P3 or P4).
3. Slot Addressing — No DIP Switches on the Chassis
Unlike some older PLC platforms, the SLC 500 chassis does not use physical DIP switches for slot addressing. Slot numbers are determined by physical position (slot 0 = processor, slots 1–12 = I/O). However, your RSLogix 500 program must match the I/O configuration to the physical slot layout. If you’re moving modules to different slot positions during the swap, update the I/O configuration in your program before going online — mismatched slot assignments will trigger a Major Fault (Type 4, Code 20).
4. Processor Memory Backup Before Power-Down
Before pulling the old chassis, upload the processor program to RSLogix 500 or save to a 1747-M1/M11/M12 memory module if installed. Do not assume the program in the processor matches the last saved version on your laptop — field modifications happen. Verify the upload checksum against your master copy.
5. Common Fault Codes After Chassis Replacement
- Major Fault Type 4, Code 20: I/O module in wrong slot or slot configuration mismatch. Correct the I/O tree in RSLogix 500 and clear the fault.
- Major Fault Type 1, Code 20: Power supply fault — check that the replacement chassis is drawing within the power supply’s rated output. Verify 1746-P series compatibility.
- Minor Fault Type 8: Communication module (DH+, DH-485, ControlNet) lost connection during swap. Re-establish network connection and verify node address settings on the communication module itself.
- No Power LED on Processor: Backplane seating issue. Power down, reseat the processor firmly until the locking tab clicks, and re-apply power.
6. Firmware Compatibility
The 1746-A13/B chassis itself carries no firmware — it is a passive backplane. Firmware compatibility concerns apply to the processor and communication modules you install into it. Confirm your SLC 5/03, 5/04, or 5/05 processor firmware revision matches the RSLogix 500 version used to program it. Mismatched firmware can cause online edit failures or instruction set errors.
Reliability in Harsh Conditions
The SLC 500 platform was engineered for industrial environments that would destroy consumer-grade electronics. The 1746-A13/B chassis reflects that design philosophy at the structural level.
The chassis frame is constructed from heavy-gauge steel with a powder-coat finish rated for continuous exposure to industrial particulate, cutting fluid mist, and cleaning agent vapors. The backplane PCB uses conformal coating on production runs, providing a moisture barrier that resists condensation cycles common in facilities with large temperature swings between shifts and shutdowns.
Vibration tolerance is validated to IEC 68-2-6 standards — the chassis maintains electrical continuity and module retention under sinusoidal vibration profiles representative of press shop floors, compressor skids, and mobile equipment installations. The module slot guides are reinforced nylon with steel inserts, preventing the guide wear that causes intermittent contact in high-vibration environments.
Operating temperature range of 0 °C to 60 °C covers the majority of industrial panel environments without forced cooling. In vertical mounting configurations with adequate panel ventilation, the chassis operates reliably at the upper end of this range. Storage tolerance down to −40 °C means units held as cold-climate spares maintain full integrity without special conditioning before deployment.
The Series B revision specifically addressed EMI susceptibility issues identified in Series A field returns. Improved ground plane routing on the backplane PCB and enhanced shielding at the power bus connectors reduce susceptibility to conducted and radiated interference from variable frequency drives, welding equipment, and high-current switching loads — the exact noise sources present in the environments where this chassis is most commonly deployed.
Global Express Logistics
Our Xiamen warehouse operates on a same-business-day dispatch model for in-stock items ordered before 15:00 CST. Here’s how the shipment moves from our shelf to your panel:
Day 0 — Order Confirmation & Export Prep: Order is confirmed, unit pulled from stock, and export documentation prepared — commercial invoice, packing list, and HS 8537.10 declaration. For orders requiring an EUC (End User Certificate) or specific country import documentation, our logistics team contacts you within two hours of order placement.
Day 0–1 — DHL / FedEx Express Pickup: Shipments move via DHL Express Worldwide or FedEx International Priority depending on destination and customer preference. Both carriers provide door-to-door tracking from Xiamen Gaoqi International Airport. We do not use economy or deferred freight services for industrial spare parts — your downtime cost exceeds the shipping premium.
Day 1–3 — Transit to Major Hubs: Southeast Asia and East Asia destinations typically receive within 1–2 business days. Europe, Middle East, and North America receive within 2–4 business days under normal customs clearance conditions. We pre-classify shipments with the correct HS code and declare accurate commercial values to minimize customs hold risk.
Customs Clearance Support: Our team provides proactive customs documentation including manufacturer certificates of origin, product datasheets for technical classification, and pre-alert notifications to your local customs broker. For destinations with known clearance complexity (Brazil, India, Russia), we advise on documentation requirements at the time of order.
Packaging: The 1746-A13/B ships in a double-wall corrugated carton with foam-in-place cushioning. The chassis is individually wrapped in anti-static poly and secured against movement. Drop-test packaging standard: ISTA 2A. Your part arrives in the same condition it left our warehouse.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.