Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Bently Nevada In Stock OK

Bently Nevada 330905-00-06-05-02-00 Proximity Probe

Request verified availability, condition, replacement risk review, packing options and courier lead time for 330905-00-06-05-02-00.

Exact part330905-00-06-05-02-00 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandBently Nevada Part Number330905-00-06-05-02-00 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 330905-00-06-05-02-00

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Bently Nevada
Primary Part Number
330905-00-06-05-02-00
Product Type
Proximity Probe
Series / Family
3309
Country of Origin
US
Catalog Category
Sensors & Switches
Operating Temp.
−35 °C to +177 °C
Compliance
API 670, CE, RoHS
Model confirmed for inquiry 330905-00-06-05-02-00 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

330905-00-06-05-02-00 In Stock — Every Hour of Downtime Costs More Than This Probe

Your turbine tripped at 03:00. The DCS alarm log is screaming shaft vibration high-high. Maintenance pulled the probe — tip shattered, cable jacket cracked from thermal cycling. The OEM lead time is six weeks. Your production manager is already on the phone. This is exactly the scenario the Bently Nevada 330905-00-06-05-02-00 stock at siemensplc.com was built for.

We hold verified inventory of the 330905-00-06-05-02-00 — a 5 mm eddy-current proximity probe from the Bently Nevada 3300 NSv Series, API 670 compliant, with integral 5 m coaxial cable. Same part number. Same sensitivity curve. Drop-in replacement for your existing Proximitor® sensor loop — no recalibration, no firmware update, no guesswork. We ship from Xiamen within 24 hours of PO confirmation via DHL Express or FedEx International Priority.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification Status
Part Number / SKU 330905-00-06-05-02-00 ✅ Ready to Ship
Brand Bently Nevada (Baker Hughes)
Series 3300 NSv Proximity Probe System
Sensing Technology Eddy Current — Non-contacting
Probe Tip Diameter 5 mm
Integral Cable Length 5 m
Thread Size M8 × 1.0
Sensitivity 7.87 V/mm (200 mV/mil)
Linear Range 0.25 mm – 2.54 mm (10 – 100 mil)
Operating Temperature −35 °C to +177 °C
Target Material (standard) AISI 4140 steel
Connector Integral coaxial / BNC-compatible
Compliance API 670, CE, RoHS
Compatible Proximitor® 3300 XL 8 mm (e.g. 330180-X1-05)
Compatible Monitor Bently Nevada 3500 Series MPS
Country of Origin United States
Shipping Origin Xiamen, China ✅ DHL / FedEx 24 h dispatch

Troubleshooting & Replacement Tips

Before you pull the probe, confirm the fault is the probe — not the Proximitor or cable. Connect a known-good extension cable directly at the Proximitor input and measure DC gap voltage. If the output is still out of the −10 V to −18 V linear window with the shaft at nominal gap, the Proximitor is suspect. If the output is rail-high or rail-low with a known-good cable, the probe is dead. Only then order the replacement.

Step-by-step field swap for 330905-00-06-05-02-00:

  1. Isolate and de-energize the Proximitor® sensor (3300 XL 8 mm). Do not hot-swap — transient voltages can damage the monitor input card.
  2. Record the existing gap voltage from the monitor display or historian before shutdown. Target reinstallation gap: typically 1.0 mm ± 0.05 mm for most 3300 NSv installations (verify your machine’s OEM spec).
  3. Loosen the lock nut (M8 × 1.0) and back the probe out. Note the number of turns — this gives you a starting reference for the new probe’s gap setting.
  4. Inspect the probe holder bore for debris, corrosion, or thread damage. Clean with a lint-free cloth. Do not use metallic tools near the probe tip area.
  5. Thread in the new 330905-00-06-05-02-00 by hand until tip-to-shaft contact, then back out to achieve the target gap. Use a feeler gauge or the Proximitor’s DC output as your reference (−10.0 V ≈ 1.0 mm gap on AISI 4140 target).
  6. Torque the lock nut to the value specified in your machine’s maintenance manual (typically 5–8 N·m for M8 probes). Over-torquing will shift the gap.
  7. Re-energize the Proximitor and verify DC gap voltage is within the linear range. Check the monitor for OK status and confirm vibration readings are within baseline.
  8. No recalibration required — the 330905-00-06-05-02-00 shares the identical sensitivity curve (7.87 V/mm) with all 3300 NSv 5 mm probes. The Proximitor does not need to be re-ranged.

Common fault codes associated with 330905-00-06-05-02-00 failure:

  • 3500/40M — Channel Not OK / Probe Fault: Gap voltage outside −2 V to −18 V window. First check cable continuity; if cable is intact, probe tip is likely damaged or the probe body has an open circuit.
  • High Vibration Alert / Danger: Sudden spike without process change — check for probe tip contamination (oil sludge, metallic particles) or mechanical loosening of the lock nut.
  • Erratic / Noisy Signal: Intermittent contact at the BNC connector or micro-fracture in the integral cable near the probe body — common after thermal cycling in high-temperature applications above 150 °C.
  • Zero-shift after maintenance: Gap was not re-set after probe swap. Re-gap to OEM specification and re-zero the monitor channel.

Configuration note: The 330905-00-06-05-02-00 does not have DIP switches or firmware. All signal conditioning is handled by the Proximitor® sensor. Ensure the Proximitor is configured for 5 mm probe type (not 8 mm) — incorrect Proximitor selection will produce a non-linear output across the measurement range.

Reliability in Harsh Conditions

The 3300 NSv probe body is machined from 316 stainless steel with a PEEK (polyether ether ketone) tip housing — a material combination chosen specifically for chemical resistance in oil mist, H₂S-laden atmospheres, and high-pressure steam environments. The integral cable uses a fluoropolymer jacket rated to +200 °C continuous, with a braided stainless steel armor layer that provides both EMI shielding and mechanical protection against abrasion in cable trays.

Vibration resistance is validated to 20 g RMS (10–2000 Hz) per IEC 60068-2-6, which covers the resonance frequencies generated by most industrial rotating equipment including high-speed centrifugal compressors running at 10,000–20,000 RPM. The probe’s eddy-current sensing element has no moving parts — there is nothing to wear, fatigue, or corrode inside the tip. Mean time between failures (MTBF) for the 3300 NSv series in continuous service exceeds 200,000 hours under normal operating conditions.

In offshore and coastal installations where salt fog and humidity are constant threats, the stainless housing and sealed cable entry point prevent ingress that would otherwise cause corrosion-induced sensitivity drift. Units destined for tropical or high-humidity environments are shipped with desiccant packs and moisture-barrier poly bags as standard practice from our Xiamen warehouse.

Global Express Logistics

Our dispatch process is built around one objective: getting the part on your machine before the next production shift. From our Xiamen warehouse, the standard export workflow runs as follows:

  1. PO received → same-day inspection and export packaging. Each unit is wrapped in anti-static foam, sealed in a moisture-barrier bag, and placed in a double-wall carton with shock-absorbing inserts. Gross weight for a single 330905-00-06-05-02-00 unit is approximately 350 g — well within DHL Express and FedEx International Priority weight thresholds for next-flight-out routing.
  2. Commercial documentation prepared in parallel: Commercial invoice (with correct HS code 9031.80 for non-electrical measuring instruments), packing list, and certificate of origin. For buyers in ASEAN countries requiring Form E (ACFTA), we prepare this on request at no additional charge.
  3. Carrier handoff within 24 hours of PO confirmation. DHL Express transit times from Xiamen: Southeast Asia 1–2 days, Middle East 2–3 days, Europe 3–4 days, North America 3–5 days. FedEx International Priority offers comparable transit with real-time tracking from pickup to delivery.
  4. Tracking number sent immediately upon carrier pickup. We provide the AWB number via email and WhatsApp so your logistics team can monitor the shipment in real time and pre-clear customs if required.
  5. Emergency freight options available: For situations where standard express is not fast enough, we can arrange next-flight-out (NFO) courier or hand-carry service to major hubs including Singapore, Dubai, Frankfurt, and Houston. Contact us directly to discuss.

We have exported industrial automation components to 40+ countries. Our team understands the documentation requirements for controlled goods, dual-use classifications, and import licensing in major markets. We will not let paperwork be the reason your machine stays down.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.