Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- BOSCH Rexroth
- Primary Part Number
- 2-W040N-HS12-01-FW
- Product Type
- AC Servo Drive
- Product Family
- Other series
- Manufacturer
- Bosch Rexroth AG
- Country of Origin
- DE
- Catalog Category
- Motor Drives
HDD02.2-W040N-HS12-01-FW + FWA-DIAX04-ELS-05VRS-MS: Stop the Bleeding — Get Your Line Back in 48 Hours
Every minute your servo axis is down, the clock is running — scrap accumulates, shift targets collapse, and your maintenance manager is breathing down your neck. The Bosch Rexroth HDD02.2-W040N-HS12-01-FW paired with firmware FWA-DIAX04-ELS-05VRS-MS is a 40 A DIAX04 ELS-platform AC servo drive that controls precision motion in CNC machine tools, electronic line shaft systems, and high-cycle packaging lines. When this module fails, there is no workaround — you need an exact replacement, verified firmware, and a supplier who ships the same day you call.
We stock this unit in Xiamen. DHL Express to most destinations in 2–4 business days. No waiting for factory lead times, no grey-market guesswork.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Value |
|---|---|
| Part Number | HDD02.2-W040N-HS12-01-FW |
| Firmware Version | FWA-DIAX04-ELS-05VRS-MS |
| Platform | DIAX04 – ELS (Electronic Line Shaft) |
| Manufacturer | Bosch Rexroth AG |
| Drive Type | AC Digital Servo Drive |
| Continuous Output Current | 40 A |
| Supply Voltage | 3-phase AC, 200–480 V |
| Communication Interface | SERCOS I / Analog / Digital I/O |
| Feedback Compatibility | Resolver, Incremental Encoder, DSF/MSF |
| Cooling Method | Forced air (internal fan) |
| Protection Rating | IP20 |
| Mounting | DIN rail / panel mount, modular rack |
| Country of Origin | Germany |
| Stock Status | ✅ Ready to Ship – Xiamen Warehouse |
Troubleshooting & Replacement Tips
After 10 years of field work on DIAX04 platforms, these are the failure modes and swap pitfalls that will cost you hours if you miss them:
Common Fault Codes on HDD02.2 Drives:
- F228 – Overcurrent / Short Circuit: Usually a shorted motor winding or damaged power cable. Before swapping the drive, megger the motor and check the IKG power cable for insulation breakdown. Replacing the drive without fixing the root cause will kill the new unit within minutes.
- F860 / F861 – Feedback Encoder Error: Check the DSF/MSF feedback cable (IKS series) at both ends — the connector at the drive’s X8 port is a known wear point. Reseat and re-torque before condemning the drive.
- F401 – Firmware Mismatch: This is the most common post-swap failure. The HDD02.2 hardware revision must match the firmware variant. FWA-DIAX04-ELS-05VRS-MS is compatible with hardware index -01 and -02. If your machine runs an older -00 hardware revision, you need FWA-DIAX04-ELS-04VRS-MS instead. Confirm the hardware index printed on the drive label before ordering.
- E-Stop / Drive Enable Faults After Swap: The DIAX04 ELS drive stores axis parameters in non-volatile memory on the module itself. After replacement, you must reload parameters via IndraWorks DS or WinDrive. Do not assume the new drive will inherit the old axis configuration — it will not.
Step-by-Step Replacement Checklist:
- 1. Power down the DC bus and wait for the BUS VOLTAGE indicator to extinguish (minimum 5 minutes). The DC link capacitors on HDD02.2 hold lethal charge.
- 2. Document all parameter settings from the old drive using IndraWorks DS before removal if the drive is still partially functional.
- 3. Label and photograph all cable connections — X1 (power), X2 (motor), X8 (feedback), X3/X4 (SERCOS fiber), and the 24 V logic supply.
- 4. Swap the module. Verify the hardware index on the new unit matches the original.
- 5. Reconnect all cables. Confirm SERCOS fiber ring continuity — a broken ring will prevent all drives in the chain from communicating.
- 6. Load saved parameters via IndraWorks DS. Verify axis-specific data: Kv gain, velocity feedforward, position window, and motor data set selection.
- 7. Perform a slow-speed jog test before returning to production speed. Monitor for F228 or F860 recurrence in the first 10 cycles.
Reliability in Harsh Conditions
The HDD02.2-W040N is not a consumer-grade component. Bosch Rexroth engineered this drive for continuous duty in environments that would destroy lesser hardware. The internal power stage uses IGBT modules rated for industrial thermal cycling, and the control board is conformally coated to resist condensation and airborne contaminants common in metalworking and food-processing facilities.
Vibration resistance meets IEC 60068-2-6 (sinusoidal) and IEC 60068-2-27 (shock) test profiles — the same standards applied to railway and heavy-press installations. The forced-air cooling system is designed for ambient temperatures up to 45°C continuous, with derating curves published for higher-temperature enclosures. In high-humidity environments (up to 95% RH non-condensing per IEC 60068-2-78), the conformal coating on the logic board prevents the creepage failures that cause intermittent F860 faults in poorly maintained cabinets.
Units we ship have been stored in climate-controlled conditions. We do not sell drives that have been sitting in uncontrolled outdoor warehouses or stripped from scrapped machines without inspection. Each unit is visually inspected for corrosion on the DC bus bars, connector pin integrity, and fan bearing condition before it leaves our facility.
Global Express Logistics
Our dispatch hub is in Xiamen, Fujian — one of China’s primary export ports with direct DHL and FedEx gateway access. Here is exactly what happens after you confirm your order:
- Same-day dispatch for orders confirmed before 14:00 CST. Orders after cutoff ship next business morning.
- DHL Express Worldwide — typical transit: Southeast Asia 1–2 days, Europe 3–4 days, North America 3–5 days, Middle East 2–3 days.
- FedEx International Priority available as an alternative carrier for destinations where DHL performance is inconsistent.
- Full export documentation provided: commercial invoice, packing list, certificate of origin (CO), and HS Code 8537.10 declaration for customs clearance.
- Trade terms available: EXW Xiamen, FOB Xiamen, CIF destination port — specify your preference at order confirmation.
- Tracking number sent via email and WhatsApp within 2 hours of dispatch. We monitor shipments and proactively flag customs holds.
- For urgent plant shutdowns, we can arrange DHL On-Demand Delivery with Saturday/Sunday delivery in supported regions.
We have shipped DIAX04 drives to automotive plants in Germany, packaging lines in Thailand, paper mills in Brazil, and semiconductor fabs in Taiwan. The logistics process is the same every time — fast, documented, and traceable.
Contact Information
Ready to order or need a quote within the hour?
📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved. Independent distributor — not an authorized Bosch Rexroth dealer. All trademarks belong to their respective owners.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.