Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- HITACHI
- Primary Part Number
- AVRC-08H
- Product Type
- Power Supply Input Module
- Series / Family
- Hitachi EX Series
- Manufacturer
- HITACHI
- Country of Origin
- Japan
- Catalog Category
- I/O Modules
- Operating Temp.
- 0 °C to +55 °C
- Warranty
- 12 months from date of shipment
HITACHI AVRC-08H — DC Bus Power Conditioning in Hitachi EX Series DCS Control Architecture
The AVRC-08H is a dedicated Power Supply Input Module engineered for integration within Hitachi’s EX Series Distributed Control System (DCS) platform. Its primary function is to receive, condition, and distribute regulated DC power across the DCS backplane, ensuring that all downstream controller cards, analog I/O modules, and communication interfaces operate within their specified supply voltage windows. In a multi-rack DCS installation, the power supply input module is not a peripheral — it is the electrical foundation upon which deterministic control loop execution depends.
Unlike generic power conversion units, the AVRC-08H is designed around the specific backplane bus architecture of the Hitachi EX Series. Its output rail impedance, transient response characteristics, and connector pinout are matched to the rack’s internal power distribution topology, eliminating the integration uncertainty that arises when third-party substitutes are used in OEM-specified slots.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Parameter | Specification |
|---|---|
| Part Number | AVRC-08H |
| Manufacturer | HITACHI |
| Series | Hitachi EX Series DCS |
| Module Function | Power Supply Input Module |
| Mounting Interface | DCS Rack Backplane Slot |
| Nominal Input Voltage | 100–240 V AC / 50–60 Hz (wide-range) |
| DC Output Rail | +24 V DC regulated (backplane bus) |
| Output Current Capacity | Up to 8 A continuous (derated above 50 °C) |
| Isolation Class | Reinforced isolation, input-to-output ≥ 2,000 V AC |
| Ripple & Noise | ≤ 50 mV peak-to-peak at full load |
| Operating Temperature | 0 °C to +55 °C |
| Storage Temperature | −25 °C to +70 °C |
| Relative Humidity | 5 % to 95 % RH, non-condensing |
| Vibration Resistance | IEC 60068-2-6: 10–57 Hz, 0.075 mm amplitude |
| EMC Compliance | IEC 61000-4-2 / -4-4 / -4-5 (ESD, EFT, Surge) |
| Weight | Approx. 1,250 g |
| Country of Origin | Japan |
| Warranty | 12 months from date of shipment |
Hardware Logical Analysis
The AVRC-08H’s internal architecture reflects the design priorities of a high-availability process control environment: electrical isolation integrity, low-noise DC output, and thermal stability under sustained load.
Reinforced Input-to-Output Isolation: The module employs a high-frequency flyback topology with a reinforced isolation barrier rated at ≥ 2,000 V AC between the AC input stage and the DC output bus. This isolation level exceeds the basic insulation requirements of IEC 61010-1 and is essential in installations where the DCS rack shares a common enclosure with field-side wiring carrying induced transients from inductive loads such as motor starters and solenoid valves.
EMC Hardening — Conducted and Radiated Immunity: The input stage incorporates a multi-stage common-mode and differential-mode filter network. This suppresses conducted interference in the 150 kHz–30 MHz band before it reaches the switching converter stage, preventing noise coupling onto the DC backplane bus. The module’s shielded transformer core and PCB layout minimize radiated emissions, maintaining compliance with IEC 61000-6-4 for industrial environments.
Transient Surge Absorption: Metal oxide varistors (MOVs) and transient voltage suppression (TVS) diodes are positioned at the AC input terminals to clamp voltage spikes up to 4 kV (1.2/50 µs waveform per IEC 61000-4-5 Level 4). This protects the downstream converter from grid-borne surges common in heavy industrial facilities with large rotating machinery.
Output Voltage Regulation and Load Transient Response: The DC output rail maintains ±1 % steady-state regulation across the full load range (0–8 A). The closed-loop control bandwidth is tuned to respond to load step transients — such as those caused by simultaneous I/O module scanning cycles — within 200 µs, preventing voltage droop that could trigger under-voltage lockout on sensitive analog input cards.
Thermal Management: The module uses a combination of copper heat spreaders on high-dissipation components and convection-optimized PCB copper pours. At 55 °C ambient with full 8 A load, junction temperatures of switching FETs remain within rated limits, supporting continuous-duty operation without forced-air cooling in standard DCS cabinet configurations.
Redundancy Arbitration Logic: When two AVRC-08H modules are installed in a redundant power supply configuration, the backplane arbitration circuit performs automatic load sharing and seamless switchover. The switchover time is designed to remain below the hold-up time of downstream module bulk capacitors, ensuring no control loop interruption during a single power supply failure event.
System Integration Benefits
- Deterministic Backplane Power Delivery: The regulated +24 V DC output with ≤ 50 mV ripple ensures that analog input modules maintain their specified common-mode rejection ratios, directly supporting measurement accuracy in PID control loops.
- Zero-Interruption Redundancy Switchover: Dual-module redundant configurations achieve sub-millisecond switchover, keeping the DCS scan cycle uninterrupted during power supply faults — critical for continuous-process industries where a control loop dropout can trigger a process upset.
- Wide AC Input Range for Global Deployment: The 100–240 V AC wide-range input eliminates the need for external autotransformers when deploying Hitachi DCS systems across different regional grid standards (50 Hz / 60 Hz), reducing BOM complexity and installation cost.
- Diagnostic Transparency via Status Outputs: The module provides discrete status signals (power-good, fault) that feed into the DCS system diagnostics layer, enabling the controller to log power supply health events with millisecond-resolution timestamps — supporting root-cause analysis of intermittent process anomalies.
- Reduced Ground Loop Risk: The reinforced isolation barrier prevents ground potential differences between the AC supply ground and the DCS logic ground from creating ground loop currents that would otherwise introduce 50/60 Hz noise into analog measurement channels.
- Thermal Derating Transparency: The module’s published derating curve (output current vs. ambient temperature) allows system engineers to accurately calculate available power headroom in high-ambient installations, preventing unplanned shutdowns due to thermal overload.
- Direct OEM Form-Fit-Function Replacement: The AVRC-08H’s mechanical envelope, connector pinout, and backplane signaling are identical to the original Hitachi factory specification. No firmware updates, jumper changes, or configuration modifications are required for a drop-in replacement in an existing rack.
- Extended MTBF for Lifecycle Cost Optimization: Hitachi’s component selection and derating practices for the AVRC-08H target an MTBF exceeding 100,000 hours at 40 °C ambient, reducing the frequency of planned maintenance interventions and unplanned spare-part procurement events over a 10–15 year plant lifecycle.
Quality Assurance & Global Logistics
Every HITACHI AVRC-08H unit dispatched from our Xiamen, China facility is sourced directly from authorized Hitachi distribution channels and undergoes a structured pre-shipment verification process. Visual inspection confirms board-level integrity — no corrosion, no mechanical damage, no counterfeit markings. Part number, revision code, and date code are cross-referenced against Hitachi’s official documentation. Where test equipment is applicable, DC output voltage and ripple are verified under a representative load before packaging.
Units are packed in anti-static (ESD) shielding bags, cushioned with conductive foam, and placed in double-wall corrugated cartons rated for international air freight handling. Each shipment includes a commercial invoice, packing list, and certificate of conformance. For projects requiring it, a country-of-origin declaration is provided for customs clearance in the destination country.
Logistics are executed via DHL Express, FedEx International Priority, and UPS Worldwide Express, with typical transit times of 3–5 business days to Europe, North America, Southeast Asia, and the Middle East. For urgent plant-down situations, same-day dispatch is available for in-stock units when orders are confirmed before 14:00 CST. All shipments are fully tracked and insured. Export control classification is assessed per EAR and applicable Chinese export regulations prior to dispatch.
The 12-month warranty covers functional failure under normal operating conditions. Warranty claims are processed with a target replacement dispatch within 5 business days of fault confirmation. Extended warranty and annual maintenance contract options are available for project procurement — contact our technical team for terms.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.