Schneider Electric 140NOE77110 Ethernet TCP/IP Module
Request verified availability, condition, replacement risk review, packing options and courier lead time for TCP/IP.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Schneider Electric
- Primary Part Number
- TCP/IP
- Product Type
- PLC Communication Module
- Series / Family
- Modicon Quantum
- Country of Origin
- FR
- Catalog Category
- Communication
- Operating Temp.
- 0°C to 60°C
- Humidity
- 5%–95% non-condensing
140NOE77110 Down? Every Minute Costs Money — We Ship Same Day from Xiamen
Your Quantum rack just threw a NET fault. The 140NOE77110 is dark. SCADA has lost its window into the process. The shift supervisor is standing behind you. You don’t need a sales pitch — you need a module on a plane tonight. We stock the Schneider Electric 140NOE77110 in Xiamen and dispatch DHL/FedEx express within hours of payment confirmation. That’s the only thing that matters right now.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification |
|---|---|
| Part Number | 140NOE77110 |
| Brand | Schneider Electric (Modicon) |
| Series | Modicon Quantum 140-series |
| Module Type | Ethernet TCP/IP Network Option Module |
| Protocol | Modbus TCP/IP, Ethernet TCP/IP, FTP, SNMP, HTTP, BOOTP/DHCP |
| Network Speed | 10/100 Mbps auto-negotiating |
| Ethernet Ports | 2 × RJ45 (dual-port, daisy-chain or star topology) |
| Backplane Interface | Modicon Quantum direct slot mount |
| Operating Temperature | 0°C to 60°C |
| Storage Temperature | -40°C to 85°C |
| Humidity | 5%–95% non-condensing |
| Certifications | CE, UL, cUL |
| Weight | 910 g |
| Hot-Standby Support | Yes (with 140CHS11000) |
| Programming Software | Unity Pro / EcoStruxure Control Expert |
| Stock Status | ✅ Ready to Ship — Xiamen, China |
Troubleshooting & Replacement Tips
Common failure signatures on the 140NOE77110:
- STS LED solid red / NET LED off: Module has lost Ethernet link. Check cable first — but if the port LEDs on both RJ45s are dead after cable swap, the internal PHY chip has likely failed. Replace the module.
- Intermittent Modbus TCP timeouts (error code 0x0B on SCADA): Classic symptom of a degraded capacitor bank on the module’s power rail. Voltage sag under load causes random TCP session drops. No firmware fix exists — hardware replacement is the only resolution.
- Module detected in Unity Pro but IP address reverts to 0.0.0.0 after power cycle: BOOTP/DHCP lease is not being retained. Check whether the module’s IP assignment mode is set to “Stored” in the network configuration tab. If it is already set to Stored and the issue persists, the onboard flash memory holding the configuration has failed.
- Hot-Standby switchover causes 140NOE77110 to go offline on the standby CPU: Firmware version mismatch between primary and standby modules. Both 140NOE77110 units in a redundant pair must run identical firmware. Use EcoStruxure Control Expert to verify and synchronize firmware versions before the next planned switchover test.
Step-by-step replacement procedure:
- Document the current IP address, subnet mask, gateway, and Modbus TCP connection table from Unity Pro / Control Expert before powering down. Screenshot the network configuration screen.
- Power down the Quantum rack or, if the system supports hot-swap on your specific backplane revision, verify the slot is safe to pull live — most field engineers do not risk this on a production rack.
- Note the slot position. The 140NOE77110 does not use DIP switches or rotary address selectors — its identity is entirely software-configured. There is no hardware addressing to replicate.
- Seat the replacement module firmly into the backplane slot. The module does not require any jumper configuration prior to insertion.
- Power up the rack. The module will boot and its STS LED should cycle through red → orange → green within approximately 45 seconds.
- Open Unity Pro / EcoStruxure Control Expert. Navigate to the network configuration for the slot. Re-enter the IP address, subnet mask, and default gateway. Set IP assignment mode to “Stored” to prevent BOOTP dependency on future reboots.
- Download the configuration to the PLC. Verify Modbus TCP connections are re-established by checking the connection table — all entries should show “Connected” status.
- If the module is part of a Hot-Standby pair, confirm the standby module’s firmware version matches the primary before re-enabling the redundancy configuration.
- Run a full I/O scan and verify SCADA data integrity. Check for any stale or frozen values that may have been cached during the outage window.
Firmware note: Schneider Electric has released multiple firmware revisions for the 140NOE77110. If your replacement unit ships with a different firmware version than the failed module, download the latest compatible firmware from the Schneider Electric Exchange portal and update via FTP or the embedded web server before going live. Mismatched firmware in a Hot-Standby pair will cause switchover failures.
Reliability in Harsh Conditions
The Modicon Quantum platform was engineered for environments where consumer-grade electronics simply stop working. The 140NOE77110 carries CE, UL, and cUL certifications and is validated against IEC 61131-2 environmental requirements. Its operating range of 0°C to 60°C covers the majority of industrial panel environments, including poorly ventilated electrical rooms in tropical climates where ambient temperatures routinely exceed 45°C.
Vibration resistance is built into the Quantum backplane mechanical design — the module locks into the backplane connector with a positive retention mechanism that prevents micro-fretting on the edge connector pins, a common failure mode in high-vibration applications such as compressor stations, marine vessels, and heavy press lines. Field experience across oil & gas installations in the Middle East and mining operations in Australia confirms that properly seated 140NOE77110 modules maintain communication integrity even under continuous 2G vibration loads.
Humidity tolerance up to 95% non-condensing means the module survives the wet seasons in Southeast Asian process plants and the steam-laden environments of food and beverage facilities without conformal coating upgrades. The PCB design uses industrial-grade components rated for extended temperature cycling, not the commercial-grade parts found in office networking equipment.
The dual RJ45 port design also provides a passive redundancy benefit at the physical layer — if one port’s magnetics degrade due to surge events on the cable run, the second port can be switched to in software without replacing the module, buying time until a planned maintenance window.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian Province, China — one of the most logistics-efficient export hubs in Asia, with direct DHL and FedEx gateway access. Here is exactly what happens after you confirm your order:
- Same-day dispatch: Orders confirmed before 15:00 CST are packed and handed to the carrier the same business day. The 140NOE77110 is pre-packed in anti-static ESD foam with desiccant and a tamper-evident outer carton — no repacking delay.
- DHL Express Worldwide: Xiamen to Frankfurt, Dubai, Singapore, Houston, or Sydney — typically 2 to 4 business days door-to-door. Tracking number provided within 2 hours of dispatch.
- FedEx International Priority: Available as an alternative carrier for destinations where FedEx has stronger last-mile coverage, including remote industrial sites in North America and Australia.
- Export documentation: Commercial invoice, packing list, and certificate of origin are prepared for every shipment. HS code 8537.10 is pre-declared for customs clearance. If your plant requires an end-user certificate or specific customs declaration format, advise us at the time of order.
- Dangerous goods: The 140NOE77110 contains no lithium batteries and is not classified as dangerous goods — no special carrier restrictions apply, which means no delays at the freight gateway.
- Insurance: Full cargo insurance is included on all express shipments. In the unlikely event of transit damage, we replace the unit immediately — we do not wait for the insurance claim to settle before shipping your replacement.
We have shipped Modicon Quantum modules to active production sites in Germany, Saudi Arabia, Indonesia, Brazil, and Canada within 72 hours of initial inquiry. When your line is down, logistics execution is not a secondary concern — it is the job.
Contact Information
📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.