Siemens 3RV1011-1GA20 Motor Starter Protector
Request verified availability, condition, replacement risk review, packing options and courier lead time for 3RV1011-1GA20.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Siemens
- Primary Part Number
- 3RV1011-1GA20
- Product Type
- Motor Starter Protector
- Series / Family
- SIRIUS
- Country of Origin
- DE
- Catalog Category
- Relays & Protection
Siemens 3RV1011-1GA20 Motor Starter Protector – Stop the Clock on Your Downtime
Every minute a production line sits idle costs real money. When a motor protection circuit trips and won’t reset — or the breaker body itself has failed — you need a verified replacement in hand, not a lead-time quote. The Siemens 3RV1011-1GA20 is a 3-pole, S00-frame motor starter protector rated 4.5–6.3 A, built for the SIRIUS modular system. We stock it in Xiamen and ship globally via DHL/FedEx express. From the moment you confirm your order, our logistics team moves — not tomorrow, today.
This is not a generic listing. It is a field-grade sourcing resource written by engineers who have pulled failed units off DIN rails at 2 AM. Every specification below is cross-referenced against Siemens documentation. Every replacement tip is drawn from real commissioning experience.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Value |
|---|---|
| Part Number | 3RV1011-1GA20 |
| Brand | Siemens |
| Series | SIRIUS 3RV1 |
| Type | Motor Starter Protector (Manual Motor Starter) |
| Frame Size | S00 |
| Poles | 3-pole |
| Rated Current Range (Ir) | 4.5 – 6.3 A (adjustable dial) |
| Rated Operational Voltage | Up to 690 V AC |
| Short-Circuit Breaking Capacity (Icu) | 100 kA @ 400 V AC |
| Terminal Type | Box-type (ring-lug) screw terminals |
| Mounting | 35 mm DIN rail or direct screw mount |
| Degree of Protection | IP20 |
| Ambient Temperature | -20 °C to +60 °C |
| Width | 45 mm |
| Standards | IEC/EN 60947-2, IEC/EN 60947-4-1, UL 508 |
| Origin | Germany |
| Stock Status | ✅ Ready to Ship – Xiamen Warehouse |
Troubleshooting & Replacement Tips
Common failure modes on the 3RV1011-1GA20:
1. Thermal trip that won’t reset after cooling
If the unit trips on overload and the reset button won’t engage after a 3-minute cool-down, the bimetal strip is likely fatigued from repeated overload cycles. Check motor FLA against the dial setting — if the dial was set above the motor’s nameplate current, the bimetal has been running hot for months. Replace the unit and reset the dial to 95–100% of motor FLA, not the maximum of the range.
2. Nuisance tripping on motor start
The 3RV1011 uses a thermal-magnetic trip mechanism. On high-inertia loads (fans, centrifuges, compressors), the magnetic instantaneous trip threshold may be too low for the locked-rotor current during start. Verify the motor’s LRC (locked-rotor current) against the protector’s instantaneous trip setting. If LRC exceeds 13× Ir, consider the 3RV1021 (S0 frame) with a higher instantaneous threshold, or add a soft starter upstream.
3. Phase failure sensitivity
The 3RV1011-1GA20 does not include built-in phase-failure sensitivity as a standard feature. If single-phasing protection is required, add the 3RV1901-1E auxiliary contact block and wire the trip signal to a PLC digital input (Simatic S7-1200 DI or equivalent) for alarm logic.
Replacement procedure (field checklist):
- De-energize the panel and verify LOTO (lockout/tagout) is applied — confirm with a CAT III multimeter at the load terminals
- Note the current dial setting on the failed unit before removal — photograph it
- Disconnect auxiliary contact blocks (3RV1901 series) by pressing the release tab; they slide off without tools
- Release the DIN rail clip at the bottom of the unit and tilt forward to remove
- On the replacement unit, set the current dial to match the original setting before installation
- Snap the new unit onto the DIN rail, reattach auxiliary blocks, and reconnect power conductors — torque to 2.5 Nm on the box terminals
- Perform a manual trip test: press the TEST button, confirm the handle moves to the tripped position, then reset
- Energize and monitor motor current for the first 5 minutes of operation
Firmware / addressing note: The 3RV1011-1GA20 is a purely electromechanical device — no firmware, no DIP switches, no bus address configuration required. If you are integrating trip status into a PROFIBUS or PROFINET network, that function is handled by the 3RV1902 communication module, not the base unit.
Reliability in Harsh Conditions
Industrial environments are not kind to electrical components. The 3RV1011-1GA20 is engineered to operate where lesser devices fail:
Vibration resistance: The S00 frame uses a reinforced contact bridge mechanism that maintains stable contact pressure under continuous vibration loads typical of compressor rooms, press lines, and marine deck installations. The box-type terminals (-1GA20 suffix) provide superior conductor retention compared to standard screw terminals under vibration — a deliberate design choice for mobile and high-vibration applications.
Thermal endurance: Rated to +60 °C ambient without derating. In practice, panels in foundries, cement plants, and outdoor enclosures in tropical climates regularly see 50–55 °C internal temperatures. The 3RV1011 handles this without nuisance tripping, provided the current dial is set correctly and the panel has adequate ventilation.
Humidity and contamination: IP20 protection covers the terminal area against direct finger contact and large particle ingress. For environments with condensation, oil mist, or conductive dust, install the unit inside an IP54 or IP65 enclosure. The internal mechanism is sealed against incidental moisture ingress during normal operation.
Electrical endurance: Rated for 100,000 mechanical operating cycles and a high number of electrical operations at rated current. In most motor protection applications — where the protector operates only on fault — this translates to a service life measured in decades, not years.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian, China — one of the most logistics-efficient export hubs in Asia, with direct DHL and FedEx gateway access.
Standard express timeline (DHL/FedEx):
- Order confirmed before 14:00 CST → same-day dispatch
- Southeast Asia: 2–3 business days door-to-door
- Europe (Germany, UK, Netherlands, Poland): 3–5 business days
- North America (USA, Canada, Mexico): 4–6 business days
- Middle East (UAE, Saudi Arabia, Qatar): 3–4 business days
- Australia / New Zealand: 4–5 business days
What ships with your order: Original Siemens packaging, product datasheet, CE/UL markings on unit, commercial invoice, packing list, and certificate of origin (CO) upon request. For orders requiring customs clearance documentation (HS code 8536.49), we prepare a complete export set as standard.
Bulk orders: For quantities above 10 pieces, contact us for consolidated sea freight options and volume pricing. Lead time for ex-factory orders on non-stocked variants is 2–4 weeks; we will confirm availability before accepting payment.
Every shipment is tracked end-to-end. You receive a DHL/FedEx tracking number within 2 hours of dispatch. If a shipment is delayed at customs, our team intervenes directly — we have handled clearance issues in over 40 countries.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.