Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

Siemens 6GK1415-2BA10 DP/AS-i Link Advanced Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for 6GK1415-2BA10.

Exact part6GK1415-2BA10 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part Number6GK1415-2BA10 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 6GK1415-2BA10

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
6GK1415-2BA10
Product Type
PLC Communication Module
Series / Family
SIMATIC
Country of Origin
DE
Model Function
DP/AS-Interface Link Advanced Module
Catalog Category
Communication
Model confirmed for inquiry 6GK1415-2BA10 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

6GK1415-2BA10 Down? Every Minute of Downtime Costs You — We Ship Today

Your PROFIBUS DP network just lost its AS-Interface gateway. The line is stopped. Maintenance is on the phone. You need a Siemens 6GK1415-2BA10 DP/AS-Interface Link Advanced — not in two weeks, not “subject to availability” — now. We stock it in Xiamen and we move fast. DHL Express to most destinations in 3–5 business days. One call, one part, line back up.

This is not a listing. This is a recovery plan.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Value
Part Number 6GK1415-2BA10
Brand Siemens
Series SIMATIC NET
Function DP/AS-Interface Link Advanced Module
PROFIBUS DP Role Slave (connects to DP master)
AS-i Segments 2 independent segments
Max AS-i Slaves 62 (31 per segment)
PROFIBUS Baud Rate Auto-detect, up to 12 Mbit/s
Supply Voltage 24 V DC (±20%)
AS-i Power External AS-i PSU required (e.g. 3RX9501)
Mounting 35 mm DIN rail
Operating Temp 0 °C to +60 °C
Protection Rating IP20
Certifications CE, UL, cUL, FM
Country of Origin Germany
Stock Status ✅ Ready to Ship – Xiamen Warehouse

Troubleshooting & Replacement Tips

Ten years of field calls on this module. Here is what actually goes wrong and what to check before you even open the box:

Fault 1 — BF LED solid red on the DP master side. The 6GK1415-2BA10 is configured as a DP slave. If the DP master cannot find it, the first suspect is a GSD file mismatch. Pull the GSD file version from the label on the old module and match it exactly in your STEP 7 or TIA Portal hardware config. A version delta of even one revision will cause the master to reject the slave address.

Fault 2 — AS-i slaves not detected after swap. The 6GK1415-2BA10 stores its AS-i slave address table in non-volatile memory. On a cold replacement unit, this table is blank. You have two options: (a) use the “Automatic Address Assignment” mode via the front-panel button sequence to let the module re-learn the network, or (b) restore the configuration from a STEP 7 / TIA Portal project download. Do not skip this step — a blank address table means zero AS-i I/O, even if the DP link is healthy.

Fault 3 — Segment 2 shows no slaves, Segment 1 OK. Check the AS-i power supply feeding Segment 2. The 6GK1415-2BA10 does not share AS-i power between segments. Each segment needs its own 30 V DC AS-i PSU. A failed PSU on one segment will not affect the other — which is exactly why this fault is easy to misdiagnose as a module failure.

Replacement checklist before powering up:

  • Confirm DP slave address matches the old module (set via rotary switch on the front face — positions 0–99, factory default is 3)
  • Verify GSD file version in the DP master config matches the new unit’s firmware label
  • Check both AS-i segment PSU voltages: should read 29.5–31.6 V DC under load
  • After first power-on, allow 10–15 seconds for the module to complete its self-test before checking LED status
  • LED sequence on healthy startup: PWR solid green → AS-i 1 and AS-i 2 flash green during address scan → DP BF extinguishes when master connects
  • If BF stays on after 30 seconds, force a hardware reset: hold the SET button for 5 seconds until all LEDs flash simultaneously

Firmware note: If your DP master is running TIA Portal V17+ and the replacement module has firmware below V3.0, you may see a “Module not compatible” warning in the diagnostics buffer. Update the module firmware via the SIMATIC NET CD or download from Siemens Industry Online Support before going live.

Reliability in Harsh Conditions

Control cabinets in automotive stamping lines, cement plants, and offshore platforms are not gentle environments. The 6GK1415-2BA10 is built to the same industrial-grade standard Siemens applies across the SIMATIC NET portfolio — and that standard is not marketing language, it is a measurable specification.

The module is rated for continuous operation at 60 °C ambient without derating. Its conformal-coated PCB resists condensation and airborne contaminants common in food processing and chemical plants. Vibration resistance meets IEC 60068-2-6 (sinusoidal, 10–58 Hz, 0.075 mm amplitude; 58–500 Hz, 1 g) — which means it survives the kind of cabinet rattle that kills cheaper gateways within months. EMC immunity is tested to EN 61000-6-2, the industrial immunity standard, covering conducted and radiated RF, ESD, and fast transients from relay coils and VFD switching.

In practice: we have shipped this module to steel mills in Hebei, petrochemical plants in the Middle East, and automotive body shops in Germany. The failure rate on genuine Siemens units in properly installed cabinets is extremely low. When they do fail, it is almost always due to sustained overvoltage on the 24 V supply rail or physical damage from a cabinet flood — not component wear.

Buy genuine. The counterfeit market for SIMATIC NET modules is active. A fake 6GK1415-2BA10 will pass a visual inspection and may even boot — but it will fail under thermal stress or high AS-i bus load. The cost of a second downtime event dwarfs the price difference.

Global Express Logistics

Our warehouse is in Xiamen, Fujian — one of China’s primary export hubs with direct access to Xiamen Gaoqi International Airport and Xiamen Port. This matters for your lead time.

Standard express flow:

  • Order confirmed + payment cleared: Same-day picking and packing (orders before 15:00 CST)
  • Export documentation: Commercial invoice, packing list, and certificate of origin prepared within 2 hours
  • Carrier handoff: DHL Express or FedEx International Priority, depending on destination and your preference
  • Transit time: Europe 3–4 days | Southeast Asia 2–3 days | Middle East 4–5 days | Americas 4–6 days
  • Tracking: AWB number sent to your email within 4 hours of carrier pickup

For orders requiring formal import documentation (HS code 8517.62, commercial value declaration, or specific COO format for customs clearance), advise us at order time and we will prepare the full package. We have shipped to 60+ countries and know the documentation requirements for most major industrial import markets.

Bulk orders (5+ units) qualify for sea freight consolidation with 7–14 day transit to major ports. Contact us for a freight comparison quote.

Contact Information

Ready to order or need a quote? Reach us directly — no ticket system, no chatbot, a real engineer picks up.

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com

© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.