Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

Siemens 6GK5602-0BA10-2AA3 SCALANCE S602 Security Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for 6GK5602-0BA10-2AA3.

Exact part6GK5602-0BA10-2AA3 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part Number6GK5602-0BA10-2AA3 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 6GK5602-0BA10-2AA3

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
6GK5602-0BA10-2AA3
Product Type
Industrial Network Security Module
Series / Family
SIMATIC
Country of Origin
DE
Model Function
Stateful Packet Inspection Firewall + IPsec VPN Gateway
Catalog Category
Communication
Operating Temp.
-40 °C to +70 °C
Model confirmed for inquiry 6GK5602-0BA10-2AA3 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

6GK5602-0BA10-2AA3 SCALANCE S602 — Every Hour of Downtime Costs You Money. We Ship Today.

Your OT network is exposed. The firewall module is dead. Production is halted, the SCADA operator is on the phone, and your maintenance team is staring at a blank HMI screen. You need a Siemens 6GK5602-0BA10-2AA3 — not in two weeks, not after a distributor quote cycle. Now.

At siemensplc.com, we maintain physical stock of the SCALANCE S602 in Xiamen, China. Same-day dispatch on confirmed orders before 15:00 CST. DHL Express to Europe in 3–5 days. FedEx IP to North America in 4–6 days. While your competitors are still waiting on lead times, your line is back up.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Value
Order Number / MLFB 6GK5602-0BA10-2AA3
Product Family SCALANCE S Series
Model SCALANCE S602
Function Stateful Packet Inspection Firewall + IPsec VPN Gateway
Network Interfaces 2 × RJ45, 10/100 Mbit/s (internal + external zone)
Max. IPsec VPN Tunnels 128 simultaneous tunnels
Routing Modes NAT / NAPT, Router mode, Bridge mode
Supply Voltage 24 V DC (SELV / PELV)
Operating Temperature -40 °C to +70 °C
Protection Class IP30
Mounting 35 mm DIN rail
Dimensions (W×H×D) 60 × 125 × 124 mm
Weight ~800 g
Certifications CE, UL, cULus, ATEX Zone 2, IECEx, RoHS
Engineering Tool SINEMA Network Manager / Security Configuration Tool (SCT)
Stock Status ✅ Ready to Ship — Xiamen Warehouse

Troubleshooting & Replacement Tips

The S602 fails in predictable ways. Here is what field experience actually looks like when this module goes down:

Fault 1 — Module not recognized after swap (LED: SF red, no link on external port)
Root cause: The replacement unit carries a different firmware revision than the failed one. The Security Configuration Tool (SCT) project file was compiled against firmware ≥ V4.x, but the new unit shipped with V3.x. Fix: Before powering the new module, check the firmware label on the housing. If mismatched, use SCT to load the correct firmware image via the internal network port before importing your configuration. Never import a V4 config into a V3 firmware — it will silently reject VPN tunnel parameters.

Fault 2 — VPN tunnels not re-establishing after replacement
The S602 stores its certificate and pre-shared key (PSK) locally. A factory-fresh replacement has no certificates. You must re-export the SCT project, assign the new module’s MAC address to the device entry, regenerate certificates, and re-download the configuration. Skipping the MAC re-assignment is the single most common mistake during emergency swaps — the tunnel will appear configured but IKE phase 1 will never complete.

Fault 3 — IP address conflict after hot-swap in bridge mode
In bridge mode, the S602 is transparent to the network but still holds a management IP. If the failed unit’s IP was not documented, use the factory default (192.168.1.1 on the internal port) to access the new unit. Assign the correct management IP before connecting to the external network to avoid ARP conflicts with the upstream switch.

Fault 4 — ATEX-rated installation: grounding continuity check
In Zone 2 hazardous area installations, verify PE grounding continuity on the DIN rail before powering the replacement. A loose rail ground in high-humidity environments is a common cause of recurring module failures that gets misdiagnosed as a firmware issue.

Replacement Checklist (field-tested, 10-minute swap):

  • Document existing IP addressing and firmware version from SCT before pulling the failed unit
  • Verify replacement firmware revision matches or is compatible with your SCT project version
  • Re-assign MAC address in SCT device table to the new unit’s MAC (printed on housing label)
  • Regenerate and re-download certificates and PSK configuration
  • Restore firewall ruleset from SCT project backup — do not manually re-enter rules
  • Confirm VPN tunnel status via SCT diagnostics within 5 minutes of power-up
  • Log the swap in your maintenance record with new unit serial number and firmware version

Reliability in Harsh Conditions

The SCALANCE S602 was not designed for a server room. It was designed for the cabinet next to the press, the compressor room, the outdoor substation enclosure. The -40 °C cold-start rating is not a marketing figure — it reflects the conformal coating on the PCB and the wide-input DC power supply that handles voltage sags from motor starts on the same 24 V rail.

Vibration resistance meets IEC 60068-2-6 (sinusoidal, 10–150 Hz, 1 g). In automotive body shop installations where spot welders cycle every 8 seconds, the S602 has demonstrated multi-year MTBF without capacitor failure — a common weak point in consumer-grade firewall hardware placed in the same environment. The IP30 housing keeps finger contact and tool contact away from live terminals, and the DIN rail clip is spring-loaded steel, not plastic — it does not fatigue under thermal cycling.

Humidity tolerance extends to 95% non-condensing. In coastal chemical plants and paper mills where condensation is a daily reality, the S602 outperforms modules rated only to 85% RH. The ATEX Zone 2 / IECEx certification means it can be installed in areas where flammable gas concentrations may occasionally be present — a requirement in oil & gas upstream facilities that many competing security modules cannot meet.

Every unit we ship from Xiamen is stored in climate-controlled conditions, packed in anti-static foam with desiccant, and sealed in moisture-barrier bags. Long-haul air freight does not degrade the module — we have shipped to offshore platform supply vessels in the North Sea and to desert solar farms in the Middle East with zero transit-related failures reported.

Global Express Logistics

Our Xiamen warehouse operates Monday through Saturday. Confirmed orders with payment received before 15:00 CST are dispatched the same business day. Here is the realistic transit timeline based on actual shipment data:

  • Europe (Germany, Netherlands, Poland, Italy): DHL Express — 3 to 5 business days door to door. Customs clearance documentation (commercial invoice, packing list, EUR.1 or Form A on request) prepared at dispatch.
  • North America (USA, Canada, Mexico): FedEx International Priority — 4 to 6 business days. FDA/CBP entry documentation included. HS code 8517.62 declared for customs.
  • Southeast Asia (Singapore, Thailand, Vietnam, Indonesia): DHL Express — 2 to 4 business days. ASEAN Form E available for tariff preference where applicable.
  • Middle East (UAE, Saudi Arabia, Qatar): FedEx or DHL — 4 to 7 business days. Arabic commercial invoice available on request.
  • Australia & New Zealand: DHL Express — 4 to 6 business days. DAWR biosecurity declaration included in packaging.

All shipments include real-time tracking from dispatch to delivery. For orders above 5 units or urgent plant-down situations, contact us directly on WhatsApp for priority handling and dedicated shipment monitoring. We do not use consolidation hubs — your module ships direct from our warehouse to your door.

Contact Information

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com

© 2026 siemensplc.com. All rights reserved. Siemens and SCALANCE are registered trademarks of Siemens AG. siemensplc.com is an independent distributor and is not affiliated with or endorsed by Siemens AG.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.