Siemens 6GK5602-0BA10-2AA3 SCALANCE S602 Security Module
Request verified availability, condition, replacement risk review, packing options and courier lead time for 6GK5602-0BA10-2AA3.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Siemens
- Primary Part Number
- 6GK5602-0BA10-2AA3
- Product Type
- Industrial Network Security Module
- Series / Family
- SIMATIC
- Country of Origin
- DE
- Model Function
- Stateful Packet Inspection Firewall + IPsec VPN Gateway
- Catalog Category
- Communication
- Operating Temp.
- -40 °C to +70 °C
6GK5602-0BA10-2AA3 SCALANCE S602 — Every Hour of Downtime Costs You Money. We Ship Today.
Your OT network is exposed. The firewall module is dead. Production is halted, the SCADA operator is on the phone, and your maintenance team is staring at a blank HMI screen. You need a Siemens 6GK5602-0BA10-2AA3 — not in two weeks, not after a distributor quote cycle. Now.
At siemensplc.com, we maintain physical stock of the SCALANCE S602 in Xiamen, China. Same-day dispatch on confirmed orders before 15:00 CST. DHL Express to Europe in 3–5 days. FedEx IP to North America in 4–6 days. While your competitors are still waiting on lead times, your line is back up.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Value |
| Order Number / MLFB | 6GK5602-0BA10-2AA3 |
| Product Family | SCALANCE S Series |
| Model | SCALANCE S602 |
| Function | Stateful Packet Inspection Firewall + IPsec VPN Gateway |
| Network Interfaces | 2 × RJ45, 10/100 Mbit/s (internal + external zone) |
| Max. IPsec VPN Tunnels | 128 simultaneous tunnels |
| Routing Modes | NAT / NAPT, Router mode, Bridge mode |
| Supply Voltage | 24 V DC (SELV / PELV) |
| Operating Temperature | -40 °C to +70 °C |
| Protection Class | IP30 |
| Mounting | 35 mm DIN rail |
| Dimensions (W×H×D) | 60 × 125 × 124 mm |
| Weight | ~800 g |
| Certifications | CE, UL, cULus, ATEX Zone 2, IECEx, RoHS |
| Engineering Tool | SINEMA Network Manager / Security Configuration Tool (SCT) |
| Stock Status | ✅ Ready to Ship — Xiamen Warehouse |
Troubleshooting & Replacement Tips
The S602 fails in predictable ways. Here is what field experience actually looks like when this module goes down:
Fault 1 — Module not recognized after swap (LED: SF red, no link on external port)
Root cause: The replacement unit carries a different firmware revision than the failed one. The Security Configuration Tool (SCT) project file was compiled against firmware ≥ V4.x, but the new unit shipped with V3.x. Fix: Before powering the new module, check the firmware label on the housing. If mismatched, use SCT to load the correct firmware image via the internal network port before importing your configuration. Never import a V4 config into a V3 firmware — it will silently reject VPN tunnel parameters.
Fault 2 — VPN tunnels not re-establishing after replacement
The S602 stores its certificate and pre-shared key (PSK) locally. A factory-fresh replacement has no certificates. You must re-export the SCT project, assign the new module’s MAC address to the device entry, regenerate certificates, and re-download the configuration. Skipping the MAC re-assignment is the single most common mistake during emergency swaps — the tunnel will appear configured but IKE phase 1 will never complete.
Fault 3 — IP address conflict after hot-swap in bridge mode
In bridge mode, the S602 is transparent to the network but still holds a management IP. If the failed unit’s IP was not documented, use the factory default (192.168.1.1 on the internal port) to access the new unit. Assign the correct management IP before connecting to the external network to avoid ARP conflicts with the upstream switch.
Fault 4 — ATEX-rated installation: grounding continuity check
In Zone 2 hazardous area installations, verify PE grounding continuity on the DIN rail before powering the replacement. A loose rail ground in high-humidity environments is a common cause of recurring module failures that gets misdiagnosed as a firmware issue.
Replacement Checklist (field-tested, 10-minute swap):
- Document existing IP addressing and firmware version from SCT before pulling the failed unit
- Verify replacement firmware revision matches or is compatible with your SCT project version
- Re-assign MAC address in SCT device table to the new unit’s MAC (printed on housing label)
- Regenerate and re-download certificates and PSK configuration
- Restore firewall ruleset from SCT project backup — do not manually re-enter rules
- Confirm VPN tunnel status via SCT diagnostics within 5 minutes of power-up
- Log the swap in your maintenance record with new unit serial number and firmware version
Reliability in Harsh Conditions
The SCALANCE S602 was not designed for a server room. It was designed for the cabinet next to the press, the compressor room, the outdoor substation enclosure. The -40 °C cold-start rating is not a marketing figure — it reflects the conformal coating on the PCB and the wide-input DC power supply that handles voltage sags from motor starts on the same 24 V rail.
Vibration resistance meets IEC 60068-2-6 (sinusoidal, 10–150 Hz, 1 g). In automotive body shop installations where spot welders cycle every 8 seconds, the S602 has demonstrated multi-year MTBF without capacitor failure — a common weak point in consumer-grade firewall hardware placed in the same environment. The IP30 housing keeps finger contact and tool contact away from live terminals, and the DIN rail clip is spring-loaded steel, not plastic — it does not fatigue under thermal cycling.
Humidity tolerance extends to 95% non-condensing. In coastal chemical plants and paper mills where condensation is a daily reality, the S602 outperforms modules rated only to 85% RH. The ATEX Zone 2 / IECEx certification means it can be installed in areas where flammable gas concentrations may occasionally be present — a requirement in oil & gas upstream facilities that many competing security modules cannot meet.
Every unit we ship from Xiamen is stored in climate-controlled conditions, packed in anti-static foam with desiccant, and sealed in moisture-barrier bags. Long-haul air freight does not degrade the module — we have shipped to offshore platform supply vessels in the North Sea and to desert solar farms in the Middle East with zero transit-related failures reported.
Global Express Logistics
Our Xiamen warehouse operates Monday through Saturday. Confirmed orders with payment received before 15:00 CST are dispatched the same business day. Here is the realistic transit timeline based on actual shipment data:
- Europe (Germany, Netherlands, Poland, Italy): DHL Express — 3 to 5 business days door to door. Customs clearance documentation (commercial invoice, packing list, EUR.1 or Form A on request) prepared at dispatch.
- North America (USA, Canada, Mexico): FedEx International Priority — 4 to 6 business days. FDA/CBP entry documentation included. HS code 8517.62 declared for customs.
- Southeast Asia (Singapore, Thailand, Vietnam, Indonesia): DHL Express — 2 to 4 business days. ASEAN Form E available for tariff preference where applicable.
- Middle East (UAE, Saudi Arabia, Qatar): FedEx or DHL — 4 to 7 business days. Arabic commercial invoice available on request.
- Australia & New Zealand: DHL Express — 4 to 6 business days. DAWR biosecurity declaration included in packaging.
All shipments include real-time tracking from dispatch to delivery. For orders above 5 units or urgent plant-down situations, contact us directly on WhatsApp for priority handling and dedicated shipment monitoring. We do not use consolidation hubs — your module ships direct from our warehouse to your door.
Contact Information
📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved. Siemens and SCALANCE are registered trademarks of Siemens AG. siemensplc.com is an independent distributor and is not affiliated with or endorsed by Siemens AG.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.