Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

Siemens 6XV1870-3QH10 Industrial Ethernet Cable

Request verified availability, condition, replacement risk review, packing options and courier lead time for 6XV1870-3QH10.

Exact part6XV1870-3QH10 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part Number6XV1870-3QH10 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 6XV1870-3QH10

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
6XV1870-3QH10
Product Type
Industrial Ethernet Cable
Product Family
Other series
Country of Origin
DE
Catalog Category
Communication
Operating Temp.
−20 °C to +70 °C
Model confirmed for inquiry 6XV1870-3QH10 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

Siemens 6XV1870-3QH10 — Stop the Clock on Your PROFINET Downtime

A broken PROFINET link doesn’t wait for business hours. When the 6XV1870-3QH10 fails — whether from connector fatigue, cable crush, or EMI-induced signal degradation — your entire network segment goes dark. Controllers lose visibility of distributed I/O, safety interlocks trip, and production output flatlines. Every minute of unplanned downtime in a mid-scale automotive or food processing plant costs between $5,000 and $20,000. We stock the Siemens 6XV1870-3QH10 precisely for this moment: same-day dispatch from Xiamen, DHL Express to your door, cable in hand before your next shift.

This is not a generic patch cord. The 6XV1870-3QH10 is a factory-assembled, 100% tested SIMATIC NET Industrial Ethernet TP Cord — 10 meters, shielded SF/UTP construction, ruggedized RJ45 on both ends, green-coded per PROFINET cabling convention. It slots directly into SCALANCE switches, S7-1500 CP ports, ET 200SP IM interfaces, and SINAMICS drive PROFINET ports without any field termination. Plug in, confirm link LED, resume production.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification Status
Part Number 6XV1870-3QH10 ✅ Ready to Ship
Brand Siemens 100% Original
Product Family SIMATIC NET Industrial Ethernet TP Cord
Cable Length 10 m
Connector Type RJ45, both ends, pre-assembled
Cable Construction SF/UTP, shielded twisted pair
Transmission Speed 10 / 100 Mbit/s (Fast Ethernet)
Protocol Compliance PROFINET, IEEE 802.3u
Operating Temperature −20 °C to +70 °C
IP Rating (connector) IP65 (with mating device)
Cable Color Green (PROFINET standard)
Approx. Weight 800 g
Origin Germany
Dispatch Location Xiamen, China Same-day available

Troubleshooting & Replacement Tips

Fault Scenario 1 — Intermittent PROFINET Communication Loss (Error Code 0xC0A2 / Station Failure)
If your S7-1500 or S7-300 is throwing station failure alarms on a specific device and the fault clears temporarily when you wiggle the cable near the RJ45 boot, the connector crimp has failed internally. This is the most common failure mode on cables that have been routed through cable drag chains or repeatedly flexed. Do not waste time re-seating — replace the 6XV1870-3QH10 immediately. After swapping, verify link status on the SCALANCE port LED (solid green = 100 Mbit/s link established). Then force a PROFINET topology scan in TIA Portal (Online → Accessible Devices) to confirm the device reappears with correct IP assignment.

Fault Scenario 2 — Device Not Found After Cabinet Rewire
If a device disappears from the PROFINET network after a panel modification, check cable polarity first — the 6XV1870-3QH10 is a straight-through patch cord, not a crossover. Plugging into an uplink port on an unmanaged switch with auto-MDI/X disabled will cause link failure. Also confirm the RJ45 is fully seated: the locking tab must click audibly. A half-inserted connector will show no link LED even though it appears physically connected.

Fault Scenario 3 — High Cycle Count Connector Wear
In applications where the cable is disconnected and reconnected frequently (mobile HMI panels, test benches, quick-change tooling stations), RJ45 connectors typically degrade after 750–1,000 mating cycles. Signs include intermittent packet loss visible in PROFINET diagnostics as CRC errors or frame retransmissions. The 6XV1870-3QH10’s ruggedized connector housing extends service life, but once wear is evident, replacement is the only reliable fix. Keep one spare per critical network segment.

Replacement Checklist:

  • Power down the affected PROFINET device before disconnecting (prevents ghost alarms in the controller).
  • Label both ends of the old cable before removal — PROFINET topology maps to physical port positions.
  • Route the new 6XV1870-3QH10 away from high-voltage cables and VFD output wiring (minimum 200 mm separation).
  • After reconnection, check TIA Portal diagnostics: Device Status should show green within 3–5 seconds of power-up.
  • If the device remains in fault state after cable replacement, check IP address conflict — PROFINET devices retain their last assigned IP; a duplicate on the subnet will prevent re-establishment.

Reliability in Harsh Conditions

The 6XV1870-3QH10 is not designed for office IT closets — it is built for the plant floor. The SF/UTP shielded construction provides a continuous foil shield plus braided outer screen, giving it superior rejection of electromagnetic interference generated by variable frequency drives, servo amplifiers, and high-current bus bars that share cable trays in industrial panels. In vibration-intensive environments such as press lines, compressor rooms, and mobile machinery, the strain relief boot on each RJ45 connector absorbs mechanical stress that would fracture a standard patch cord’s conductor terminations within weeks.

Temperature cycling is another silent killer of standard Ethernet cables. The 6XV1870-3QH10’s jacket compound is formulated to remain flexible at −20 °C — critical for outdoor control cabinets in northern climates — while maintaining dimensional stability at sustained +70 °C, which is realistic inside a sealed enclosure on a hot summer day. The cable has been validated against IEC 61918 (Industrial Communication Networks — Installation of Communication Infrastructure) and meets PROFINET cabling Category C requirements, which mandate specific attenuation, return loss, and crosstalk performance thresholds that generic Cat5e cables frequently fail under industrial test conditions.

Humidity and condensation are addressed through the shielded construction’s moisture barrier and the IP65-rated connector interface when mated with a compatible PROFINET device port. This makes the 6XV1870-3QH10 suitable for food processing environments where washdown cycles create high ambient humidity, and for outdoor junction boxes where temperature swings cause condensation on cable surfaces.

Global Express Logistics

Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to Xiamen Gaoqi International Airport and Xiamen Port. This geographic position gives us consistent access to DHL Express, FedEx International Priority, and UPS Worldwide Express services with daily cut-off times that allow same-day dispatch for orders confirmed before 15:00 CST.

Typical Transit Times from Xiamen:

  • Southeast Asia (Singapore, Thailand, Malaysia, Vietnam): 2–3 business days via DHL Express
  • Middle East (UAE, Saudi Arabia, Qatar): 3–4 business days via FedEx International Priority
  • Europe (Germany, Netherlands, Poland, UK): 4–5 business days via DHL Express Worldwide
  • North America (USA, Canada, Mexico): 4–6 business days via FedEx International Priority
  • South America (Brazil, Chile, Colombia): 6–8 business days via DHL Express
  • Australia & New Zealand: 3–5 business days via DHL Express

Every shipment includes a commercial invoice, packing list, and certificate of origin. For customers in countries with import duty exemptions on industrial automation components, we can provide HS code documentation (HS 8544.42) to support customs clearance. Full tracking numbers are issued within 2 hours of dispatch and shared via email and WhatsApp. For critical plant shutdowns requiring overnight delivery, contact us directly — we have access to priority freight lanes that are not available through standard online booking channels.

Contact Information

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.