Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- SST
- Primary Part Number
- 5136-PBMS-ISA
- Product Type
- PROFIBUS Communication Card
- Product Family
- Other series
- Manufacturer
- SST (Woodhead / Molex)
- Country of Origin
- CA
- Catalog Category
- Communication
- Operating Temp.
- 0°C to +60°C
- Humidity
- 5% – 95% RH, non-condensing
- Warranty
- 12 months from date of shipment
- Compliance
- CE, FCC Class A
SST 5136-PBMS-ISA PROFIBUS-DP Master ISA Card — Stop the Clock on Your Downtime
Your PROFIBUS network is down. The ISA-bus host PC is throwing communication faults. The line has been stopped for two hours and every minute is costing money. This is the exact scenario the SST 5136-PBMS-ISA replacement stock at siemensplc.com is built for. We hold verified inventory in Xiamen, China, and ship via DHL Express and FedEx International Priority — most destinations in Southeast Asia, Europe, and the Middle East receive parts within 48–72 hours of order confirmation.
The 5136-PBMS-ISA is SST’s (Woodhead / Molex) dedicated PROFIBUS-DP Master interface card for legacy ISA-bus industrial PCs. It carries an onboard microprocessor that handles the full PROFIBUS-DP protocol stack independently, offloading the host CPU entirely. Dual-port RAM provides the data exchange bridge between the card and the host application. This architecture means the card is deterministic — cycle times do not drift under host CPU load, which is exactly what you need in a process control environment where a missed I/O update can trigger a safety interlock.
If your plant still runs ISA-slot industrial PCs — and many do, particularly in chemical, power generation, and discrete manufacturing — the 5136-PBMS-ISA is one of the few remaining genuine-stock options on the market. Counterfeit and remarked cards are circulating. Every unit we ship is sourced through traceable channels and inspected before dispatch.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification |
|---|---|
| Part Number | 5136-PBMS-ISA |
| Manufacturer | SST (Woodhead / Molex) |
| Series | 5136 |
| Bus Interface | ISA (Industry Standard Architecture), 16-bit |
| Protocol | PROFIBUS-DP Master (EN 50170 / IEC 61158) |
| Baud Rate Range | 9.6 kbps – 12 Mbps (auto-negotiated) |
| Max Slave Nodes | 125 PROFIBUS-DP slave devices per segment |
| Physical Connector | DB-9 female (RS-485, pin-compatible with standard PROFIBUS connectors) |
| Host Power Draw | 5 VDC via ISA slot (no external PSU required) |
| Onboard Processor | Dedicated microprocessor — full protocol stack offload |
| Data Exchange | Dual-port RAM shared memory interface |
| OS / Driver Support | Windows XP / 7 / 10 (32-bit); SST Network Configuration Tool (NCT) |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | 5% – 95% RH, non-condensing |
| Compliance | CE, FCC Class A |
| Warranty | 12 months from date of shipment |
| Stock Status | ✔ Ready to Ship — Xiamen, China |
Troubleshooting & Replacement Tips
Common failure symptoms that indicate the 5136-PBMS-ISA needs replacement:
- Host application reports “PROFIBUS Master not found” or “Card initialization failed” at startup — the onboard microprocessor has failed to boot or the ISA slot contact has degraded.
- Intermittent slave device dropouts at baud rates above 1.5 Mbps — often caused by oscillator drift on aging cards operating in high-ambient-temperature enclosures.
- Dual-port RAM read/write errors logged by the SST driver — indicates memory cell degradation, typically after 10+ years of continuous operation.
- Card detected in Device Manager but PROFIBUS network shows zero active slaves — firmware corruption or EEPROM failure; a replacement card is faster than reflashing in a live environment.
Replacement procedure — key configuration checkpoints:
- ISA I/O Base Address: The 5136-PBMS-ISA uses jumper or software-selectable I/O base addresses (commonly 0x300 or 0x310). Before pulling the failed card, document the current address setting from the SST NCT software or Device Manager resource tab. Set the replacement card to the identical address to avoid driver reconfiguration.
- IRQ Assignment: Note the IRQ line assigned to the original card. ISA IRQ conflicts are a common commissioning trap — verify no other ISA device shares the same IRQ on the host PC.
- Driver Version Match: SST released multiple driver versions for the 5136 series. The replacement card must use the same driver version as the original to maintain GSD file compatibility with your PROFIBUS slave configuration. Do not auto-update drivers during a live plant recovery.
- PROFIBUS Node Address: The master node address is set in software (SST NCT), not on the card hardware. After installing the replacement, re-import your saved NCT project file — do not reconfigure from scratch under time pressure.
- Termination Check: After card swap, verify PROFIBUS bus termination at both physical ends of the segment. A missing terminator is the most common cause of a network that “almost works” after a card replacement.
- Baud Rate Lock: If your network runs at a fixed baud rate (e.g., 1.5 Mbps), confirm the NCT project file has baud rate locked — do not leave it on auto-detect in production.
Reliability in Harsh Conditions
The 5136-PBMS-ISA was designed for continuous 24/7 operation in industrial panel environments, not office-grade computing. The card’s onboard microprocessor architecture provides inherent isolation between the PROFIBUS physical layer and the host ISA bus — a transient on the RS-485 line does not propagate to the host system memory space.
- Thermal tolerance: Rated 0°C to +60°C operating ambient. In practice, cards installed in sealed enclosures with poor ventilation regularly operate at the upper boundary. The onboard components are selected for industrial temperature grades, not commercial.
- Vibration resistance: ISA card edge connectors on the 5136 series use gold-plated contacts with a retention force specification that maintains electrical continuity under IEC 60068-2-6 vibration profiles typical of machine tool and press environments.
- EMC performance: The card meets FCC Class A and CE EMC requirements. The RS-485 physical layer includes common-mode choke filtering on the DB-9 interface, reducing susceptibility to conducted interference from VFD switching noise — a frequent source of PROFIBUS communication errors in motor-heavy environments.
- Humidity: Conformal coating on production-grade units provides protection against condensation events during plant startup after cold weekends. Verify coating status on your specific unit if operating in high-humidity environments.
- ESD protection: Transient voltage suppression (TVS) diodes on the RS-485 data lines protect against electrostatic discharge events during cable connection and disconnection in the field.
Global Express Logistics
Our dispatch hub is located in Xiamen, China — a major international cargo port with direct DHL, FedEx, and UPS express lanes to all major industrial regions. Here is the standard process from your order confirmation to parts in hand:
- Order Confirmation → Same-Day Dispatch: Orders confirmed before 15:00 CST are packed and handed to the courier the same business day. ESD-safe anti-static bag, foam-lined outer carton, and fragile labeling are standard.
- DHL Express Worldwide: Typical transit times — Southeast Asia: 1–2 days; Europe: 2–3 days; Middle East: 2–3 days; North America: 3–4 days; South America / Africa: 4–6 days.
- FedEx International Priority: Available as an alternative carrier for destinations where FedEx has stronger local delivery networks (e.g., parts of the US, Canada, Mexico).
- Export Documentation: Commercial invoice, packing list, HS code declaration (8537.10 / 8471.80 as applicable), and certificate of origin provided with every shipment. Customs clearance delays are minimized by accurate pre-clearance documentation.
- Shipment Tracking: AWB number provided within 2 hours of dispatch. Real-time tracking link sent directly to your procurement contact.
- Emergency Freight: For critical plant-down situations, contact us directly via WhatsApp for same-day courier booking and priority handling confirmation.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.