Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Schneider Electric In Stock OK

Schneider Electric LC1D09M7C AC Contactor

Request verified availability, condition, replacement risk review, packing options and courier lead time for LC1D09M7C.

Exact partLC1D09M7C RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSchneider Electric Part NumberLC1D09M7C ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ LC1D09M7C

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Schneider Electric
Primary Part Number
LC1D09M7C
Product Type
AC Contactor
Product Family
Other series
Country of Origin
FR
Catalog Category
Relays & Protection
Operating Temp.
-5°C to +60°C
Model confirmed for inquiry LC1D09M7C Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

LC1D09M7C Down? Every Minute of Downtime Costs You Money — We Ship Today

Your motor line just tripped. The contactor is burnt. Maintenance is standing by. You’ve already lost 20 minutes pulling the panel apart and confirming the fault — now you need the Schneider Electric LC1D09M7C in your hands, not in a warehouse queue. We stock this unit in Xiamen and dispatch same-day on confirmed orders. No middlemen. No delays. Just the part you need, moving toward your facility right now.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification
Part Number LC1D09M7C
Brand Schneider Electric
Series TeSys D
Pole Configuration 3-Pole (3P + 1NO/1NC aux)
Main Contact Rating 9A (AC-3, 400V)
Motor Power @ 400V 4 kW
Coil Voltage 220V AC, 50/60 Hz (suffix M7C)
Auxiliary Contacts 1 NO + 1 NC (integrated)
Mounting DIN rail or screw mount
Standards IEC 60947-4-1, CE, UL, CSA
Operating Temperature -5°C to +60°C
Mechanical Life 10,000,000 operations
Electrical Life (AC-3) 1,000,000 operations
Enclosure Rating IP20
Weight ~1,210 g (with packaging)
Origin France
Stock Status ✅ Ready to Ship — Xiamen Warehouse

Troubleshooting & Replacement Tips

After ten years of field work, the LC1D09M7C fails in predictable ways. Here’s what to check before you even pull the unit:

Fault Code / Symptom: Contactor chatters or hums excessively
Root cause: Coil voltage is low or fluctuating. Measure AC supply at A1–A2 terminals under load. If voltage drops below 185V AC during energization, the coil cannot hold the armature closed. Check control transformer sizing and wiring resistance. Do not replace the contactor until supply voltage is confirmed stable — you’ll burn through the new unit in days.

Fault Code / Symptom: Motor trips on overload but contactor appears fine
Root cause: Welded main contacts. With the panel de-energized and LOTO applied, manually depress the contactor actuator. If the contacts do not spring open freely, they are welded. This is common after a downstream short-circuit event. Replace the contactor and inspect the LRD overload relay — if the bimetal tripped on fault current, the relay calibration may have shifted. Replace both as a set.

Fault Code / Symptom: Contactor energizes but motor does not run
Root cause: Open main contact on one phase. Use a multimeter in continuity mode across each L1/T1, L2/T2, L3/T3 pair with the contactor manually held closed. A missing phase will show open circuit. Single-phase running causes motor overheating within minutes — shut down immediately.

Replacement Procedure (field-verified, 8-minute swap):

  1. Isolate and LOTO the control circuit at A1/A2 and the main circuit at L1/L2/L3.
  2. Photograph the existing wiring before disconnecting — especially auxiliary contact terminals 13/14 and 21/22.
  3. Disconnect main power cables (L1, L2, L3) and load cables (T1, T2, T3). Note cable ferrule sizes — LC1D09 accepts up to 4mm² on main terminals.
  4. Disconnect coil wires at A1 and A2. Confirm coil voltage label on the new unit matches: M7C = 220V AC.
  5. Unclip from DIN rail (depress bottom clip with flathead screwdriver) or remove mounting screws.
  6. Snap new LC1D09M7C onto DIN rail. Verify it seats fully — a partial clip is a vibration failure waiting to happen.
  7. Reconnect in reverse order. Torque main terminals to 2.5 N·m. Coil terminals to 1.2 N·m.
  8. Before energizing: confirm auxiliary contact block (if fitted) is fully snapped onto the front face — a loose LA1D block will cause intermittent control faults.
  9. Energize control circuit only. Verify contactor pulls in cleanly with no chatter. Measure coil current if a clamp meter is available — should be within 10% of nameplate VA.
  10. Restore main circuit. Run motor at no-load first, then under load. Monitor for 5 minutes.

Configuration Note — Coil Voltage Verification: The suffix M7C is critical. M = 220V AC, B = 24V AC, F = 110V AC, P = 230V AC. Installing a wrong-suffix unit into a 220V control circuit with a 110V coil will result in immediate coil burnout. Always read the label on the coil housing before installation, not just the part number on the box.

Auxiliary Contact Block Compatibility: If the failed unit had an LA1DN11 or LA1DN20 snap-on block fitted, transfer it directly to the new contactor — it is fully compatible. No re-wiring required if the block is undamaged.

Reliability in Harsh Conditions

The TeSys D platform was not designed for clean-room environments. It was built for the kind of panels that run 24/7 in cement plants, water treatment stations, and offshore platforms where ambient temperature swings 40°C between day and night shifts.

The LC1D09M7C silver-alloy main contacts are rated for 1 million AC-3 switching operations — that’s roughly 11 years of continuous duty at one switch per 5 minutes. The double-break contact geometry reduces arc energy per operation, which directly translates to longer contact life in high-cycle applications like conveyor starters and pump alternators.

Vibration resistance is validated to IEC 60068-2-6: 2–13.2 Hz at 1mm displacement, 13.2–100 Hz at 0.7g. In practice, this means the LC1D09M7C survives being mounted directly on compressor skids and reciprocating pump bases without contact bounce or nuisance tripping — a failure mode that plagues cheaper contactors in the same frame size.

Humidity performance is validated to 95% RH non-condensing. The coil encapsulation prevents moisture ingress that causes insulation breakdown in tropical and coastal installations. Field experience in Southeast Asian petrochemical plants confirms service intervals exceeding 5 years without coil replacement in properly sealed panels.

Operating temperature ceiling of +60°C means the LC1D09M7C handles summer panel temperatures in non-air-conditioned enclosures without derating. At +55°C ambient, full 9A rating is maintained. Above +60°C, derate per Schneider’s thermal correction curves — but at that point, your panel cooling design is the real problem.

Global Express Logistics

Our Xiamen warehouse operates on a same-day dispatch model for orders confirmed before 15:00 CST. Here’s exactly what happens after you place your order:

Hour 0–2: Order confirmation and stock verification. We pull the unit, photograph the label and packaging, and send you confirmation with the actual serial number. No surprises at customs.

Hour 2–6: Export documentation prepared. Commercial invoice, packing list, and certificate of origin issued. HS Code 8536.49 (contactors <1000V) declared correctly — no customs holds due to misclassification.

Hour 6–24: DHL Express or FedEx International Priority pickup. Tracking number sent to your email within 2 hours of carrier collection.

Transit Times from Xiamen:

  • Southeast Asia (SG, MY, TH, VN): 2–3 business days
  • Middle East (AE, SA, QA): 3–4 business days
  • Europe (DE, NL, PL, UK): 4–5 business days
  • North America (US, CA, MX): 4–6 business days
  • Australia / New Zealand: 3–5 business days

For genuine plant-down emergencies, we can arrange DHL On-Demand Delivery with Saturday and Sunday delivery options in most major markets. Contact us directly on WhatsApp for real-time logistics coordination — we respond within 15 minutes during business hours and within 2 hours outside them.

All shipments are fully insured at declared value. In the rare event of transit damage, we initiate replacement dispatch within 24 hours of your damage report — no waiting for carrier claim resolution on your end.

Contact Information

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.