Allen-Bradley 20F11NC011JA0NNNNN PowerFlex 753 AC Drive
Request availability, condition, lead time and export shipping details for 20F11NC011JA0NNNNN.
20F11NC011JA0NNNNN
Technical Details
- Brand
- Allen-Bradley
- Part Number
- 20F11NC011JA0NNNNN
- Product Type
- AC Drive
- Series / Family
- PowerFlex
- Manufacturer
- Allen-Bradley / Rockwell Automation
- Country of Origin
- US
- Catalog Category
- Motor Drives
- Availability Signal
- 100 source record, RFQ confirmation required
- Image Set
- 1 watermarked product photo
- Tags
- 20F11NC011JA0NNNNN, AC Drive, Allen-Bradley, PowerFlex 753, Rockwell Automation, VFD
20F11NC011JA0NNNNN PowerFlex 753 — Every Hour of Downtime Costs You. We Ship Today.
Your line is down. The conveyor stopped mid-shift. The drive tripped and won’t reset. You’ve pulled the fault codes, you’ve cycled power twice, and now you’re staring at a dead Allen-Bradley 20F11NC011JA0NNNNN with a production manager breathing down your neck. We’ve been there — and we built this inventory specifically for moments like this.
The 20F11NC011JA0NNNNN is a PowerFlex 753 frame-C AC drive rated at 5.5 kW / 11 A on a 380–480 V three-phase supply. It ships with embedded dual-port EtherNet/IP, a built-in dynamic braking transistor, and SIL 2 Safe Torque Off — no option cards required for most standard installations. We stock it. It leaves Xiamen today via DHL Express or FedEx International Priority. Your panel can be back online before the next shift.
⚡ URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Catalog Number | 20F11NC011JA0NNNNN |
| Series | PowerFlex 753 |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Output Power | 5.5 kW / 7.5 HP |
| Input Voltage | 380–480 V AC, 3-Phase, 50/60 Hz |
| Output Current (ND) | 11 A |
| Output Current (HD) | 9 A |
| Frame Size | Frame C |
| Enclosure Rating | IP20 / Open Type |
| Control Modes | V/Hz, Sensorless Vector (SVC), Flux Vector (FVC) |
| Communication | Embedded Dual-Port EtherNet/IP (DLR capable) |
| Safety Function | Safe Torque Off (STO) — SIL 2 / PLd, built-in |
| Digital I/O | 6 DI / 2 DO (expandable via option cards) |
| Analog I/O | 2 AI / 1 AO |
| Dynamic Braking | Internal transistor (external resistor required) |
| Certifications | UL, CE, RoHS |
| Weight | ~6.4 kg |
| Stock Status | ✅ Ready to Ship — Same Day Dispatch |
Troubleshooting & Replacement Tips
Top fault codes that kill a 20F11NC011JA0NNNNN in the field:
F005 — OverVoltage: DC bus exceeded 810 V. Usually caused by regenerative load with no braking resistor, or a supply voltage spike. Before swapping the drive, check your incoming line voltage under load and verify the braking resistor is correctly sized and wired to terminals BR+ / BR−. A drive that trips F005 repeatedly on a good supply is likely a failed braking IGBT — replace the unit.
F012 — HW OverCurrent: Output current exceeded hardware limit. Check for a shorted motor winding (megger test at 500 V DC), a seized bearing causing locked-rotor current, or a ground fault on the output cable. If the motor checks out clean, the drive’s output bridge is gone — order the replacement now.
F025 — Decel Inhibit: Drive can’t decelerate within the set ramp time. Increase decel time (P535) or add a braking resistor. Not a hardware failure — but if it’s new behavior on an existing installation, check for increased inertia load or a worn motor.
F063 — SW OverCurrent: Software current limit tripped. Often a sign of motor degradation or a mechanical overload. Run a motor nameplate check against P035–P038 before condemning the drive.
Replacement procedure — what to do before you power up the new unit:
- Document the parameter file. If the old drive still powers up (even faulted), connect via Studio 5000 or a 20-HIM-A6 and upload the full parameter set. Save to a USB. This saves 2–4 hours of re-commissioning.
- Check the catalog suffix. The suffix JA0NNNNN encodes the HIM type (J = 20-HIM-A6 installed), option slot A configuration, and factory options. Confirm your replacement matches — a suffix mismatch means different I/O wiring or missing option cards.
- Verify firmware revision. Check P29 [Drive Firmware Rev] on the old unit. The replacement should match or be newer. Older firmware on a new drive can cause AOP incompatibility in Studio 5000.
- EtherNet/IP node address. The 20F11NC011JA0NNNNN uses embedded Ethernet — IP address is set via P26 [IP Address Config] or BOOTP/DHCP. Set the IP before connecting to the network to avoid address conflicts that will fault your entire DLR ring.
- STO wiring. Terminals 1 and 2 (STO_A and STO_B) must be jumpered or connected to your safety relay output before the drive will enable. A missing STO connection gives a non-obvious F059 fault — check this first if the new drive won’t run.
- Download parameters. Restore the saved parameter file. Verify motor nameplate data (P035–P042), accel/decel ramps, and any application-specific tuning. Run autotune (P70 = 2) if the motor is accessible and unloaded.
Reliability in Harsh Conditions
The PowerFlex 753 platform was engineered for environments where consumer-grade electronics fail within weeks. The 20F11NC011JA0NNNNN is built to operate continuously at ambient temperatures up to 50°C (122°F) with derating, and survives storage at −40°C. The conformal-coated PCBs resist condensation and airborne contaminants — critical in food processing, chemical plants, and coastal installations where humidity regularly exceeds 95% non-condensing.
Vibration tolerance meets IEC 60068-2-6 at 1 G, 10–500 Hz — the drive stays operational on conveyor frames and compressor skids where mechanical resonance is a constant threat. The power stage uses industrial-grade IGBTs with a proven thermal management design; the heatsink is external to the control board, so a thermal event in the power section doesn’t take out the logic. Altitude rating extends to 1000 m without derating, and up to 3300 m with current reduction — relevant for mining and high-altitude process installations.
Every unit we ship has been inspected for physical integrity, label authenticity, and firmware version. We do not sell grey-market or refurbished units without explicit disclosure. If you need a factory-new sealed unit with full Rockwell Automation traceability documentation, specify this at the time of order.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian, China — one of China’s primary export hubs with direct DHL and FedEx gateway access. Here’s exactly what happens after you confirm your order:
Day 0 (Order Confirmed): Unit is pulled from bonded stock, inspected, and packed in anti-static foam with original manufacturer packaging where available. Commercial invoice, packing list, and HS code documentation (HS 8504.40) are prepared simultaneously.
Day 0–1 (Dispatch): Shipment handed to DHL Express or FedEx International Priority. Tracking number issued within 2 hours of pickup. For orders confirmed before 14:00 CST, same-day dispatch is standard.
Transit Times (typical, not guaranteed):
- Southeast Asia (Singapore, Thailand, Vietnam): 2–3 business days
- Middle East (UAE, Saudi Arabia, Qatar): 3–4 business days
- Europe (Germany, UK, Netherlands, Poland): 3–5 business days
- North America (USA, Canada, Mexico): 4–6 business days
- South America (Brazil, Chile, Colombia): 5–8 business days
- Australia / New Zealand: 3–5 business days
We handle all export documentation including ECCN classification, certificate of origin, and customs value declaration. For customers in countries with import duty exemptions on industrial automation components, we can provide supporting documentation to facilitate customs clearance. Duties and import taxes are the buyer’s responsibility unless DDP (Delivered Duty Paid) terms are agreed in advance.
For critical downtime situations, contact us directly on WhatsApp — we can arrange weekend dispatch and provide real-time shipment updates until the unit is in your hands.
Contact Information
📧 Email: [email protected]
📱 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026. All rights reserved.