Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Yokogawa In Stock OK

YOKOGAWA F3LC11-1N PLC Communication Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for F3LC11-1N.

Exact partF3LC11-1N RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandYokogawa Part NumberF3LC11-1N ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ F3LC11-1N

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Yokogawa
Primary Part Number
F3LC11-1N
Product Type
PLC Communication Module
Series / Family
FA-M3
Manufacturer
YOKOGAWA Electric Corporation
Country of Origin
JP
Catalog Category
Communication
Operating Temp.
0°C to +55°C
Humidity
10% to 90% RH (non-condensing)
Model confirmed for inquiry F3LC11-1N Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

YOKOGAWA F3LC11-1N FA-M3 Computer Link Module — Stop the Clock on Your Downtime

Your FA-M3 rack just dropped the computer link. The SCADA screen is frozen. The shift supervisor is on the phone. Every minute offline is money walking out the door — and you already know the part number: F3LC11-1N. We have it. It ships today from Xiamen. That’s the only thing that matters right now.

The F3LC11-1N is YOKOGAWA’s dedicated Computer Link Module for the FA-M3 (F3 Series) PLC platform. It handles high-speed serial communication between the FA-M3 CPU backplane and host computers, SCADA systems, or MES layers via RS-232C or RS-422/485. When this module fails, your entire supervisory data loop goes dark. There is no workaround — it must be replaced with the correct part, correctly configured, and fast.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification
Part Number F3LC11-1N
Manufacturer YOKOGAWA Electric Corporation
Series FA-M3 (F3 Series)
Module Function Computer Link Communication Module
Communication Interface RS-232C / RS-422/485
Protocol YOKOGAWA Computer Link (proprietary)
Compatible CPUs F3SP22-0S, F3SP28-3N, F3SP38-6N, F3SP53-4H, F3SP58-6H, F3SP67-6S, F3SP71-4N, F3SP76-7N
Compatible Base Units F3BU04-0N, F3BU06-0N, F3BU13-0N
Programming Software WideField3 / WideField2
Operating Temperature 0°C to +55°C
Storage Temperature -20°C to +70°C
Humidity 10% to 90% RH (non-condensing)
Weight (packaged) 2,140 g
Origin Japan
Stock Status ✅ Ready to Ship — Xiamen, China

Troubleshooting & Replacement Tips

Ten years of field calls on FA-M3 systems teach you that the F3LC11-1N fails in predictable ways. Here’s what to check before you pull the module — and what to nail down when you drop the new one in.

Common failure signatures:

  • ERR LED solid red: Hardware fault confirmed — the module has failed internally. No parameter reset recovers this. Pull it and replace.
  • COM LED not blinking during active polling: Check the RS-232C or RS-422 cable first. A broken shield or reversed TX/RX wiring on the DB9 kills the link before the module is even implicated. Swap the cable before condemning the card.
  • CPU shows LINK ERR in WideField3 diagnostics: Baud rate mismatch. On the F3LC11-1N, station number and baud rate are configured via WideField3 software parameters — not hardware DIP switches. Confirm the host COM port settings match exactly: baud rate, data bits (8), parity, stop bits.
  • Intermittent dropouts under load: Backplane connector oxidation. Clean the gold-finger edge connector with isopropyl alcohol before seating the replacement. A dirty slot makes a new module look faulty.
  • Module powers up but host cannot establish session: Station address conflict. Multiple F3LC11-1N modules in the same rack each require a unique station number in WideField3. Check for duplicates.

Replacement field checklist:

  • Power down the FA-M3 rack at the power supply module. Do not hot-swap this module.
  • Note the slot position — the F3LC11-1N must return to the same slot for the CPU to recognize it without a full parameter reload.
  • Inspect the backplane slot connector pins before insertion. Clean if necessary.
  • After power-up, open WideField3 and confirm station number, baud rate, and communication mode match your previous configuration. Restore from a project file backup if available.
  • Verify the ERR LED extinguishes within 5 seconds of power-up. If it stays on, recheck slot assignment and parameter settings.
  • Run a manual communication test from the host PC. Confirm read/write cycles complete without timeout errors.
  • Log the replacement: module serial number, date, slot, technician. Required for audit compliance in process industries.

Reliability in Harsh Conditions

The FA-M3 platform was built for process industries, not office environments. The F3LC11-1N reflects that. Its PCB carries conformal coating to resist moisture ingress in high-humidity environments — coastal chemical plants, paper mills, food processing facilities where steam and condensation are daily realities. The backplane connector uses gold-plated contacts rated for thousands of insertion cycles, maintaining low contact resistance through years of thermal cycling.

Vibration resistance meets IEC 61131-2 requirements — the same standard applied to PLC hardware in compressor stations, pump skids, and rotating machinery where structural vibration is continuous. The module locks positively into the FA-M3 base unit, preventing micro-movement that causes intermittent contact faults in high-vibration installations.

Operating range of 0°C to +55°C covers the vast majority of industrial control room and panel enclosure environments. For installations approaching the upper limit — a non-air-conditioned substation in Southeast Asia in August — verify panel ventilation and check that adjacent modules are not generating excess heat. The F3LC11-1N draws from the backplane 5 VDC rail; a marginal power supply module running below spec will cause erratic behavior that mimics a faulty communication module. Measure backplane voltage before condemning the F3LC11-1N.

Every unit we ship is inspected for physical integrity: label authenticity, connector condition, housing cracks, and date-code consistency. Modules with damaged edge connectors or missing firmware labels are quarantined, not sold.

Global Express Logistics

We ship from Xiamen, Fujian Province — one of China’s primary export hubs with direct DHL and FedEx gateway access. This matters when you are counting hours, not days.

  • DHL Express Worldwide: Xiamen to Southeast Asia, Middle East, and Europe in 2–4 business days. North America typically 3–5 business days.
  • FedEx International Priority: Comparable transit with strong Americas and Europe coverage. We select the carrier based on your destination and urgency.
  • Same-day dispatch cutoff: Orders confirmed and paid before 15:00 CST ship the same business day. Orders after cutoff ship the following morning.
  • Export documentation: Commercial invoice, packing list, and Certificate of Origin prepared for every shipment. HS code 8537.10 applies. We handle China-side export clearance.
  • Packaging: Anti-static bag, foam-lined carton, outer corrugated box. No bubble-wrap-only or loose-fill packing for electronic modules.
  • Tracking: AWB number sent to your email within 2 hours of dispatch with real-time tracking link.
  • Bulk orders: For quantities above 5 units or combined FA-M3 component orders, contact us for consolidated shipping pricing.

Contact Information

Ready to order or need a lead time confirmation before raising a PO? Reach us directly — no ticketing system, no chatbot queue.

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com

© 2026 siemensplc.com. All rights reserved. Independent specialist supplier of industrial automation components.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.