Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Allen-Bradley In Stock OK

Allen-Bradley 1794-OB16PXT Digital Output Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for 1794-OB16PXT.

Exact part1794-OB16PXT RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandAllen-Bradley Part Number1794-OB16PXT ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 1794-OB16PXT

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Allen-Bradley
Primary Part Number
1794-OB16PXT
Product Type
Digital Output Module
Series / Family
Flex I/O
Manufacturer
Allen-Bradley / Rockwell Automation
Country of Origin
US
Catalog Category
I/O Modules
Operating Temp.
-20°C to +60°C (extended range)
Model confirmed for inquiry 1794-OB16PXT Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

1794-OB16PXT Down? Every Minute Costs Money — Ship Today from Xiamen

Line stopped. Maintenance team on standby. Procurement scrambling. If you’re reading this, you already know what a failed Allen-Bradley 1794-OB16PXT costs per hour. This 16-point 24VDC sourcing digital output module is a load-bearing node in thousands of FLEX I/O installations worldwide — conveyors, packaging lines, automotive body shops, water treatment panels. When it fails, nothing downstream moves.

We stock the 1794-OB16PXT in Xiamen, China, with same-day dispatch available on confirmed orders placed before 15:00 CST. DHL Express and FedEx International Priority put this module on your bench in 2–5 business days, anywhere on the planet. No waiting on distributor lead times. No 6-week factory backorders. Just a verified, original unit moving toward your facility right now.

⚡ URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification
Part Number 1794-OB16PXT
Manufacturer Allen-Bradley / Rockwell Automation
Series FLEX I/O (1794 Series)
Module Type Digital Output — Sourcing (PNP)
Output Points 16 individually protected channels
Output Voltage 24V DC
Output Current 0.5A per point (8A max total)
Operating Temperature -20°C to +60°C (extended range)
Backplane Current 75mA @ 5V DC
Communication Via FLEX I/O adapter (1794-AENT, 1794-ACN15, 1794-ADN)
Mounting DIN rail via FLEX I/O terminal base (1794-TB3 / TB3S / TB3T)
Certifications UL, CE, cUL, RoHS
Stock Status ✅ Ready to Ship — Xiamen Warehouse
Lead Time Same-day dispatch (orders before 15:00 CST)

Troubleshooting & Replacement Tips

The 1794-OB16PXT fails in predictable ways. Here’s what I see in the field, and how to handle the swap without creating new problems:

Common Failure Signatures:

  • All 16 outputs dead, module LED solid red: Internal power fault or blown output driver IC. The module’s onboard protection has tripped. Do not attempt to reset by cycling power repeatedly — you risk damaging the terminal base. Replace the module.
  • Intermittent outputs on channels 8–15: Classic symptom of thermal cycling fatigue on the second output driver bank. Often correlates with enclosures running above 50°C ambient. Check panel ventilation before installing the replacement.
  • Module not recognized by adapter after power-up: Check the terminal base seating. The 1794-OB16PXT must click firmly into the 1794-TB3 base — a partial seat causes the adapter to report a missing module in RSLogix/Studio 5000. Also verify the adapter firmware is current; older 1794-AENT firmware (pre-4.x) has known compatibility issues with XT-series modules.
  • Fault code 16#0004 in Studio 5000: Output overcurrent on one or more channels. Identify the shorted field device before installing the replacement — putting a new module into a shorted load will kill it within minutes.
  • Fault code 16#0010: Module configuration mismatch. The replacement module must match the I/O configuration stored in the controller project. In Studio 5000, verify the module definition under the I/O tree matches catalog number 1794-OB16PXT, not a generic 1794-OB16.

Replacement Procedure (Field-Tested):

  1. Inhibit the module in Studio 5000 (right-click → Properties → Connection → check “Inhibit Module”) before physical removal. This prevents the controller from faulting the entire FLEX I/O bank.
  2. De-energize the 24VDC field power supply feeding the terminal base. Confirm with a meter — do not rely on the panel label alone.
  3. Slide the module straight out of the terminal base. No tools required. Note the orientation tab — the replacement seats only one way.
  4. Inspect the terminal base connector pins for corrosion or bent contacts before inserting the new module. A damaged base will fault the new module immediately.
  5. Seat the 1794-OB16PXT firmly until you feel the latch engage. Restore field power, then un-inhibit the module in Studio 5000.
  6. The module self-configures from the controller project — no DIP switches, no manual addressing. FLEX I/O uses auto-addressing based on slot position. Confirm the module status LED goes green within 5 seconds of un-inhibiting.
  7. Verify all 16 output channels in the I/O diagnostic screen before releasing the line.

Firmware Note: The 1794-OB16PXT itself carries no user-upgradeable firmware. However, the adapter module (1794-AENT, etc.) firmware version directly affects module recognition. If the replacement module shows a configuration fault immediately after seating, update the adapter firmware first.

Reliability in Harsh Conditions

The “XT” suffix on the 1794-OB16PXT is not marketing — it designates Rockwell’s extended temperature and conformal coating specification. This matters in real installations:

  • Temperature extremes: Rated to -20°C, making it suitable for cold-storage automation, outdoor enclosures in northern climates, and unheated equipment rooms. The upper limit of +60°C provides headroom in poorly ventilated panels that routinely run 10–15°C above ambient.
  • Vibration resistance: The XT series meets IEC 60068-2-6 vibration testing — relevant for modules mounted near compressors, presses, or mobile equipment. Standard (non-XT) FLEX I/O modules are not rated for the same vibration profile.
  • Humidity and condensation: Conformal coating on the PCB provides protection against moisture ingress, a common failure mode in food & beverage and outdoor utility installations where washdown or condensation cycles occur daily.
  • EMI immunity: CE marking includes compliance with IEC 61000-4 series immunity tests. In environments with large VFDs, welding equipment, or high-current switching, the 1794-OB16PXT maintains signal integrity where lesser modules introduce spurious output toggling.

Bottom line: if your application runs in anything other than a climate-controlled, vibration-free environment, the XT variant is the correct choice — and it’s what we stock.

Global Express Logistics

Our dispatch hub is in Xiamen, Fujian Province — one of China’s primary export ports with direct access to DHL, FedEx, and UPS international gateways. Here’s how a typical urgent order moves:

  • Order confirmed before 15:00 CST: Module is pulled, inspected, ESD-bagged, and handed to the courier the same afternoon.
  • DHL Express / FedEx International Priority: Transit time 2–4 business days to Europe, North America, Southeast Asia, and the Middle East. 3–5 days to South America and Africa.
  • Tracking: AWB number sent within 2 hours of dispatch. Real-time tracking link provided via email and WhatsApp.
  • Customs documentation: Commercial invoice, packing list, and HS code declaration (8537.10) prepared for every shipment. We have experience clearing industrial automation components through EU, US, and Australian customs without delays.
  • Bulk orders: For quantities above 10 units or mixed-BOM orders, we coordinate consolidated shipments to reduce per-unit freight cost. Contact us for a freight quote.

We have shipped 1794-series modules to manufacturing plants in Germany, the United States, Brazil, Australia, Saudi Arabia, and Vietnam. The process is routine. Your downtime window is not — so we treat every order as urgent by default.

Contact Information

📧 Email: [email protected]
📱 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com

© 2026 siemensplc.com. All rights reserved. All brand names and part numbers are the property of their respective owners and are referenced for identification purposes only.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.