Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Allen-Bradley
- Primary Part Number
- 1788-ENBT
- Product Type
- Communication Module
- Series / Family
- ControlLogix
- Manufacturer
- Allen-Bradley (Rockwell Automation)
- Country of Origin
- US
- Catalog Category
- Communication
- Operating Temp.
- 0°C to 60°C
- Warranty
- 90-day replacement guarantee
Allen-Bradley 1788-ENBT: Stop the Clock on Your Downtime — Ship Today from Xiamen
Your line is down. Every minute the conveyor sits idle, every batch that misses its window, every shift that runs at zero output — it all converts directly into money leaving your operation. The Allen-Bradley 1788-ENBT EtherNet/IP Daughterboard is the single component standing between you and full production recovery. We stock it. We ship it. We’ve done this hundreds of times for plants that couldn’t wait.
This is not a catalog listing. This is a field-ready replacement unit, inspected, verified, and staged for same-day dispatch via DHL Express or FedEx International Priority from our Xiamen warehouse. If you’re reading this during a breakdown, stop scrolling and contact us now.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification |
|---|---|
| Manufacturer | Allen-Bradley (Rockwell Automation) |
| Part Number | 1788-ENBT |
| Module Type | EtherNet/IP Daughterboard |
| Network Protocol | EtherNet/IP (CIP over Ethernet) |
| Communication Speed | 10/100 Mbps, auto-negotiating |
| Connector Type | RJ-45 |
| IP Configuration | BOOTP / DHCP / Static |
| Compatible Host Modules | 1788-CN2DN, 1788-CN2FF, 1788-CN2PA, 1788-CN2PB |
| Operating Temperature | 0°C to 60°C |
| Storage Temperature | -40°C to 85°C |
| Relative Humidity | 5% to 95% non-condensing |
| Power Source | Host module backplane |
| Certifications | UL, CE, C-Tick |
| Series Revisions | /A, /B |
| Stock Status | ✅ Ready to Ship — Xiamen Warehouse |
| Dispatch Lead Time | Same day (order before 15:00 CST) |
| Warranty | 90-day replacement guarantee |
Troubleshooting & Replacement Tips
Swapping a 1788-ENBT under pressure is not the time to learn on the job. Here is what experienced FAEs know that the manual does not tell you clearly enough.
Step 1 — Confirm the fault is the daughterboard, not the host module. The 1788-ENBT sits on the 1788-CN2xx bridge. If your bridge module MS LED is solid red and the NS LED is off or flashing red, the daughterboard is the likely culprit. If both LEDs are dark, suspect the host module or backplane power first.
Step 2 — Power down before removal. The 1788-ENBT is NOT hot-swappable. Attempting to remove it under power risks corrupting the host module firmware and damaging the edge connector. Kill the rack power, wait 10 seconds for capacitors to discharge, then proceed.
Step 3 — Check the series revision before installing. A /A revision daughterboard on a /B host module can cause firmware handshake failures. Match the series suffix. Check the label on the host module side panel — it shows the compatible daughterboard revision range.
Step 4 — IP address reassignment. The replacement 1788-ENBT ships with no IP address configured. Your network will not see it until you assign one. Use RSLinx Classic or Studio 5000 EtherNet/IP configuration tool with BOOTP/DHCP server enabled. If your plant uses static addressing, have the original IP, subnet mask, and gateway ready before you power up. Failure to pre-configure this is the number one cause of replacement-did-not-fix-it calls.
Step 5 — Firmware version check. After installation, go online with Studio 5000 and verify the module firmware matches what your project file expects. A mismatch generates a Module Mismatch fault (fault code 16#0107). Download the correct firmware from Rockwell PCDC before the swap if you have internet access on-site.
Common fault codes associated with 1788-ENBT failure:
- 16#0001 — Connection Request Error: Daughterboard not responding to EtherNet/IP connection requests. Replace the 1788-ENBT.
- 16#0203 — Connection Timeout: Network cable or daughterboard RJ-45 port failure. Swap cable first, then module.
- 16#0107 — Module Mismatch: Firmware or series revision incompatibility. Verify revision and update firmware.
- 16#0204 — Port Not Available: Daughterboard not seated correctly or edge connector damaged. Reseat or replace.
Step 6 — Verify EDS file registration. After the module comes online, RSNetWorx for EtherNet/IP should auto-detect it. If it shows as an unknown device, manually register the EDS file from Rockwell website. This is common when replacing with a newer series revision.
Reliability in Harsh Conditions
Industrial environments do not care about your maintenance schedule. The 1788-ENBT is built to operate where conditions are hostile by design — and our stocked units are verified to meet those same standards.
Vibration resistance: The daughterboard edge connector and PCB are designed to withstand continuous vibration loads consistent with IEC 60068-2-6 test profiles. In automotive stamping and heavy press applications, units have demonstrated multi-year service life without connector fatigue failures when properly seated.
Thermal cycling tolerance: Operating across 0°C to 60°C with storage down to -40°C, the 1788-ENBT handles the thermal shock of cold-start mornings in unheated substations and the sustained heat of enclosed control panels in summer. Onboard components are rated for industrial-grade temperature cycling, not commercial-grade shortcuts.
Humidity and condensation: Rated to 95% relative humidity non-condensing. In food processing and coastal facilities where humidity is a constant challenge, the conformal coating on the PCB provides a meaningful barrier against moisture ingress. If your panel has active condensation, address the root cause — no module survives standing water indefinitely.
EMI/RFI immunity: CE-certified compliance means the module meets EN 61000 immunity standards. In environments with large VFDs, welding equipment, or high-current bus bars nearby, ensure your Ethernet cable is shielded STP Cat5e or better and properly grounded at the panel end. The module itself is not the weak link — unshielded cabling is.
Pre-shipment verification: Every 1788-ENBT unit leaving our Xiamen facility is visually inspected for connector pin integrity, PCB surface condition, and label authenticity. Units showing any sign of rework, pin damage, or counterfeit markings are rejected. You receive a field-ready module, not a gamble.
Global Express Logistics
Xiamen is not a random warehouse location. It is a major international cargo hub with direct DHL and FedEx gateway operations, giving us access to the fastest international transit lanes available to industrial buyers worldwide.
How your order moves:
- Order confirmed before 15:00 CST: Same-day pick, pack, and handoff to DHL Express or FedEx International Priority.
- Export documentation: Commercial invoice, packing list, and HS code declaration prepared and submitted electronically at time of handoff — no customs delays from missing paperwork.
- Transit times (typical): Southeast Asia 1–2 days | Europe 3–4 days | North America 2–3 days | Middle East 3–5 days | South America 4–6 days.
- Tracking: AWB number sent to your email within 2 hours of carrier pickup. Real-time tracking link included.
- Customs clearance support: We provide all documentation required for import clearance in major markets. For destinations with specific import requirements, contact us in advance and we will prepare the correct paperwork set.
- Insurance: All shipments are covered for declared value. Additional cargo insurance available on request for high-value orders.
We have shipped to plants in Germany, the United States, Australia, Saudi Arabia, Mexico, and across Southeast Asia — often with the module arriving before the customer internal procurement process would have even generated a purchase order. That speed is the point.
Contact Information
Production lines do not wait for business hours. Neither do we.
📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.