Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Allen-Bradley In Stock OK

Allen-Bradley 1794-OF41 Analog Output Module – FLEX I/O

Request verified availability, condition, replacement risk review, packing options and courier lead time for 1794-OF41.

Exact part1794-OF41 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandAllen-Bradley Part Number1794-OF41 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 1794-OF41

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Allen-Bradley
Primary Part Number
1794-OF41
Product Type
Analog Output Module
Series / Family
Flex I/O
Country of Origin
US
Catalog Category
I/O Modules
Operating Temp.
0 °C to +55 °C (IEC 60068-2-1/2)
Warranty
12 months from date of shipment
Model confirmed for inquiry 1794-OF41 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

Allen-Bradley 1794-OF41 FLEX I/O 4-Channel Isolated Analog Output Module: Precision Signal Delivery in Closed-Loop Process Control

In continuous process industries — refining, chemical synthesis, pharmaceutical batch manufacturing, and utility power generation — the integrity of the analog output signal chain is a direct determinant of loop stability. A 4–20 mA command signal that drifts by 0.1 mA at a control valve positioner translates to a measurable deviation in flow rate, pressure, or temperature. The Allen-Bradley 1794-OF41 is engineered to eliminate that drift. As a four-channel, fully isolated analog output module within Rockwell Automation’s FLEX I/O platform, it delivers calibrated, repeatable signal output across each channel independently, with no shared ground path between channels or between channels and the backplane bus.

The 1794-OF41 occupies a specific architectural position in the FLEX I/O product family: it is the isolated-output variant designed for field environments where ground potential differences between field devices and the control panel are unavoidable. In large plant footprints — where cable runs to actuators and VFDs can exceed 200 meters — non-isolated output modules introduce ground loop currents that corrupt the intended command signal. The 1794-OF41 breaks that path at the module level, making it the correct engineering choice for multi-drop analog output topologies in mixed-voltage field environments.

Each output channel supports both current (4–20 mA, 0–20 mA) and voltage (0–10 V, ±10 V) output modes, configured independently via the module’s Add-On Profile in Studio 5000 Logix Designer. The 12-bit digital-to-analog converter (DAC) provides 4,096 discrete output steps, yielding a resolution of approximately 3.9 µA per count in 4–20 mA mode — sufficient for tight PID loop control in flow, pressure, and temperature applications where setpoint granularity matters.

📦 Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

Part Number 1794-OF41
Brand Allen-Bradley (Rockwell Automation)
Series FLEX I/O
Module Type Isolated Analog Output
Output Channels 4 (independently configurable)
Current Output Range 4–20 mA / 0–20 mA
Voltage Output Range 0–10 V DC / ±10 V DC
DAC Resolution 12-bit (4,096 counts)
Current Output Load 0–750 Ω maximum
Voltage Output Load ≥ 1 kΩ minimum
Isolation Type Channel-to-channel and channel-to-backplane
Isolation Voltage 250 V AC continuous (channel-to-backplane)
Backplane Current Draw 75 mA @ 5 V DC (backplane); 3 mA @ 24 V DC
Field Power Supply 20.4–26.4 V DC (user-supplied, per channel)
Operating Temperature 0 °C to +55 °C (IEC 60068-2-1/2)
Storage Temperature −40 °C to +85 °C
Relative Humidity 5–95% non-condensing
Compatible Terminal Bases 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T
Compatible Adapters 1794-AENT (EtherNet/IP), 1794-ACN15 (ControlNet), 1794-ADN (DeviceNet)
Certifications UL 508, CE (EMC + LVD), cUL, RoHS
Weight Approx. 200 g
Warranty 12 months from date of shipment

Hardware Logical Analysis

The 1794-OF41’s isolation architecture is implemented at the per-channel level using DC-DC converter isolation for the field power domain and optocoupler-based signal barriers for the DAC output path. This dual-barrier approach means that neither the signal reference nor the field supply voltage of any one channel shares a conductive path with adjacent channels or with the FLEX I/O backplane’s 5 V logic rail. In practical terms, a ground fault on Channel 3’s field wiring — a common occurrence in aging cable trays — does not propagate to Channel 1’s output or corrupt the backplane communication bus.

The 12-bit DAC operates on a successive-approximation architecture with an internal voltage reference. Output settling time is specified at under 1 ms for a full-scale step change (0 to 20 mA), which is well within the update rate requirements of most PID loops executing at 100 ms scan intervals. The module’s output hold behavior on communication loss is configurable: outputs can be commanded to hold last value, ramp to a defined safe state, or go to zero — a critical parameter for fail-safe valve positioning in process applications.

EMC performance is addressed through the module’s internal layout: the analog output circuitry is physically separated from the digital logic section, with a ground plane partition between the two domains. The terminal base connector provides a chassis ground path that is separate from the signal common, allowing the installer to implement a single-point grounding scheme at the panel level without creating inadvertent ground loops through the module’s internal circuitry. This design is consistent with IEC 61000-4-4 (electrical fast transient) and IEC 61000-4-5 (surge) immunity requirements applicable to industrial control equipment.

The module’s backplane interface uses the FLEX I/O proprietary serial bus, which operates at a fixed clock rate independent of the network adapter’s communication cycle. This decoupling means that EtherNet/IP network jitter or ControlNet scheduled bandwidth variations do not directly affect the DAC update timing — the adapter buffers the output data and the module applies it on the next backplane cycle. For applications with strict output update determinism requirements, this architecture provides a predictable worst-case latency bounded by the adapter’s RPI (Requested Packet Interval) setting plus one backplane cycle.

System Integration Benefits

  • Ground Loop Elimination: Full channel-to-channel and channel-to-backplane isolation prevents ground loop currents from corrupting analog output accuracy in multi-drop field wiring topologies — directly reducing calibration drift and loop offset errors.
  • Independent Channel Configuration: Each of the four channels can be independently assigned to current or voltage output mode via Studio 5000 AOP, without hardware jumpers or DIP switches — reducing commissioning time and eliminating configuration errors from physical switch misreads.
  • Deterministic Output Latency: The backplane-decoupled DAC update architecture bounds worst-case output latency to one RPI cycle plus one backplane frame, providing a calculable and repeatable control loop delay for PID tuning purposes.
  • Fail-Safe Output Behavior: Configurable fault state (hold last value / go to defined value / go to zero) allows the control engineer to define actuator behavior on communication loss at the module level, without relying on PLC program logic that may not execute during a communication fault.
  • Multi-Protocol Adapter Compatibility: The 1794-OF41 operates identically across DeviceNet, ControlNet, and EtherNet/IP adapter variants, preserving the module investment across network migration projects — a common scenario in DCS-to-PLC conversion programs.
  • Studio 5000 Native AOP Support: The module’s Add-On Profile provides tag-based access to per-channel output data, fault status, and calibration offsets directly in the controller tag database — eliminating the need for custom MSG instructions or manual data mapping.
  • High Channel Density in Compact Form Factor: Four isolated output channels in a single FLEX I/O slot reduces panel space consumption compared to discrete signal conditioners or relay-isolated output cards, lowering BOM cost and wiring labor per channel.
  • Diagnostic Transparency: The module reports per-channel fault status (open-circuit detection on current outputs, over-range conditions) back to the controller tag structure, enabling the PLC program to generate maintenance alarms without additional field instrumentation.

Quality Assurance & Global Logistics

Every 1794-OF41 unit dispatched from our Xiamen, China facility is sourced from authorized distribution channels and verified industrial surplus networks with documented chain of custody. Pre-shipment inspection covers physical label integrity, date-code verification against known Rockwell Automation production batches, connector pin condition, and anti-static packaging with humidity indicator cards. Units that do not pass inspection are quarantined and not listed for sale.

Shipments originate from Xiamen, China — a major export hub with direct access to DHL Express, FedEx International Priority, and UPS Worldwide Express services. Typical transit times: Europe 3–5 business days, North America 4–7 business days, Southeast Asia 2–3 business days. Both EXW and CIF Incoterms are available. Each shipment includes a commercial invoice, packing list, and certificate of origin. Traceability documentation is available on request. The 12-month warranty covers manufacturing defects and verified functional failures under normal operating conditions.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier